Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop Solution

STEP 0: Pre-Calculation Summary
Formula Used
Path Length = Plate Pressure Drop*Equivalent Diameter/(8*Friction Factor*(Fluid Density*(Channel Velocity^2))/2)
Lp = ΔPp*De/(8*Jf*(ρfluid*(up^2))/2)
This formula uses 6 Variables
Variables Used
Path Length - (Measured in Meter) - Path Length refers to the distance that the fluid travels between the plates. It represents the length of the flow path within the heat exchanger channels formed by adjacent plates.
Plate Pressure Drop - (Measured in Pascal) - Plate Pressure Drop refers to the loss of fluid pressure as the fluid flows through the channels formed by the plates.
Equivalent Diameter - (Measured in Meter) - Equivalent diameter represents a single characteristic length that takes into account the cross-sectional shape and flow path of a non-circular or irregularly shaped channel or duct.
Friction Factor - Friction Factor is a dimensionless quantity used to characterize the amount of resistance encountered by a fluid as it flows through a pipe or conduit.
Fluid Density - (Measured in Kilogram per Cubic Meter) - Fluid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies.
Channel Velocity - (Measured in Meter per Second) - Channel Velocity refers to the average velocity of the fluid flowing through the channels formed by adjacent plates.
STEP 1: Convert Input(s) to Base Unit
Plate Pressure Drop: 2070.467 Pascal --> 2070.467 Pascal No Conversion Required
Equivalent Diameter: 16.528 Millimeter --> 0.016528 Meter (Check conversion ​here)
Friction Factor: 0.004 --> No Conversion Required
Fluid Density: 995 Kilogram per Cubic Meter --> 995 Kilogram per Cubic Meter No Conversion Required
Channel Velocity: 1.845 Meter per Second --> 1.845 Meter per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Lp = ΔPp*De/(8*Jf*(ρfluid*(up^2))/2) --> 2070.467*0.016528/(8*0.004*(995*(1.845^2))/2)
Evaluating ... ...
Lp = 0.631470130671129
STEP 3: Convert Result to Output's Unit
0.631470130671129 Meter -->631.470130671129 Millimeter (Check conversion ​here)
FINAL ANSWER
631.470130671129 631.4701 Millimeter <-- Path Length
(Calculation completed in 00.052 seconds)

Credits

Creator Image
Created by Rishi Vadodaria
Malviya National Institute Of Technology (MNIT JAIPUR ), JAIPUR
Rishi Vadodaria has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has verified this Calculator and 200+ more calculators!

Basic Formulas of Heat Exchanger Designs Calculators

Equivalent Diameter for Triangular Pitch in Heat Exchanger
​ LaTeX ​ Go Equivalent Diameter = (1.10/Pipe Outer Diameter)*((Tube Pitch^2)-0.917*(Pipe Outer Diameter^2))
Equivalent Diameter for Square Pitch in Heat Exchanger
​ LaTeX ​ Go Equivalent Diameter = (1.27/Pipe Outer Diameter)*((Tube Pitch^2)-0.785*(Pipe Outer Diameter^2))
Number of Tubes in Center Row Given Bundle Diameter and Tube Pitch
​ LaTeX ​ Go Number of Tubes in Vertical Tube Row = Bundle Diameter/Tube Pitch
Number of Baffles in Shell and Tube Heat Exchanger
​ LaTeX ​ Go Number of Baffles = (Length of Tube/Baffle Spacing)-1

Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop Formula

​LaTeX ​Go
Path Length = Plate Pressure Drop*Equivalent Diameter/(8*Friction Factor*(Fluid Density*(Channel Velocity^2))/2)
Lp = ΔPp*De/(8*Jf*(ρfluid*(up^2))/2)

What is the Significance of Plate Pressure Drop in Plate Type Heat Exchanger?

Plate pressure drop in a plate-type heat exchanger refers to the loss of fluid pressure as the fluid flows through the channels formed by the plates. It is a measure of the resistance encountered by the fluid as it moves through the narrow passages between the plates. Plate pressure drop is a critical consideration in the design and operation of plate heat exchangers. Several factors contribute to plate pressure drop, including the fluid velocity, viscosity, flow rate, and the geometric configuration of the plates (such as plate spacing and pattern). Higher fluid velocities and more complex plate arrangements tend to increase pressure drop.

How to Calculate Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop?

Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop calculator uses Path Length = Plate Pressure Drop*Equivalent Diameter/(8*Friction Factor*(Fluid Density*(Channel Velocity^2))/2) to calculate the Path Length, The Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop formula is defined as the distance that the fluid travels between the plates. It represents the length of the flow path within the heat exchanger channels formed by adjacent plates. Path Length is denoted by Lp symbol.

How to calculate Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop using this online calculator? To use this online calculator for Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop, enter Plate Pressure Drop (ΔPp), Equivalent Diameter (De), Friction Factor (Jf), Fluid Density fluid) & Channel Velocity (up) and hit the calculate button. Here is how the Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop calculation can be explained with given input values -> 631470.1 = 2070.467*0.016528/(8*0.004*(995*(1.845^2))/2).

FAQ

What is Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop?
The Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop formula is defined as the distance that the fluid travels between the plates. It represents the length of the flow path within the heat exchanger channels formed by adjacent plates and is represented as Lp = ΔPp*De/(8*Jf*(ρfluid*(up^2))/2) or Path Length = Plate Pressure Drop*Equivalent Diameter/(8*Friction Factor*(Fluid Density*(Channel Velocity^2))/2). Plate Pressure Drop refers to the loss of fluid pressure as the fluid flows through the channels formed by the plates, Equivalent diameter represents a single characteristic length that takes into account the cross-sectional shape and flow path of a non-circular or irregularly shaped channel or duct, Friction Factor is a dimensionless quantity used to characterize the amount of resistance encountered by a fluid as it flows through a pipe or conduit, Fluid Density is defined as the ratio of mass of given fluid with respect to the volume that it occupies & Channel Velocity refers to the average velocity of the fluid flowing through the channels formed by adjacent plates.
How to calculate Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop?
The Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop formula is defined as the distance that the fluid travels between the plates. It represents the length of the flow path within the heat exchanger channels formed by adjacent plates is calculated using Path Length = Plate Pressure Drop*Equivalent Diameter/(8*Friction Factor*(Fluid Density*(Channel Velocity^2))/2). To calculate Path Length of Fluid in Plate Heat Exchanger Given Channel Velocity and Plate Pressure Drop, you need Plate Pressure Drop (ΔPp), Equivalent Diameter (De), Friction Factor (Jf), Fluid Density fluid) & Channel Velocity (up). With our tool, you need to enter the respective value for Plate Pressure Drop, Equivalent Diameter, Friction Factor, Fluid Density & Channel Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!