STEP 0: Pre-Calculation Summary
Formula Used
Partial Pressure = ((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))+Partial Pressure in air
Pw = ((hConv*(T∞-Tw))/(hfg*kL))+P∞
This formula uses 7 Variables
Variables Used
Partial Pressure - Partial pressure of the water vapor at wet bulb temperature.
Convective Heat Transfer Coefficient - (Measured in Watt per Square Meter per Kelvin) - Convective Heat Transfer Coefficient is the heat transfer due to convection.
Air Temperature - Air temperature is the temperature of the air surrounding an individual and is typically measured in degrees Celsius (°C) or in Kelvin.
Wet Bulb Temperature - Wet Bulb Temperature is the temperature of the wet bulb and denoted by the symbol Tw.
Enthalpy of Evaporation - (Measured in Joule per Kilogram K) - Enthalpy of evaporation is the amount of energy (enthalpy) that must be added to a liquid substance to transform a quantity of that substance into a gas.
Convective Mass Transfer Coefficient - (Measured in Meter per Second) - Convective Mass Transfer Coefficient is a function of geometry of the system and the velocity and properties of the fluid similar to the heat transfer coefficient.
Partial Pressure in air - Partial pressure in air of the water vapor is the pressure of water in the mixture of water and air.
STEP 1: Convert Input(s) to Base Unit
Convective Heat Transfer Coefficient: 0.5 Watt per Square Meter per Kelvin --> 0.5 Watt per Square Meter per Kelvin No Conversion Required
Air Temperature: 35 --> No Conversion Required
Wet Bulb Temperature: 14 --> No Conversion Required
Enthalpy of Evaporation: 90 Joule per Kilogram K --> 90 Joule per Kilogram K No Conversion Required
Convective Mass Transfer Coefficient: 0.0095 Meter per Second --> 0.0095 Meter per Second No Conversion Required
Partial Pressure in air: 0.016 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pw = ((hConv*(T∞-Tw))/(hfg*kL))+P∞ --> ((0.5*(35-14))/(90*0.0095))+0.016
Evaluating ... ...
Pw = 12.296701754386
STEP 3: Convert Result to Output's Unit
12.296701754386 --> No Conversion Required
FINAL ANSWER
12.296701754386 12.2967 <-- Partial Pressure
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Nishan Poojary
Shri Madhwa Vadiraja Institute of Technology and Management (SMVITM), Udupi
Nishan Poojary has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Rajat Vishwakarma
University Institute of Technology RGPV (UIT - RGPV), Bhopal
Rajat Vishwakarma has verified this Calculator and 400+ more calculators!

Humidification Calculators

Gas phase heat transfer coefficient in dehumidification
​ LaTeX ​ Go Gas Phase Heat Transfer Coefficient = ((Liquid Phase Heat Transfer Coefficient*(Inside Temperature-Liquid layer temperature))-(Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti))))/(Bulk Gas Temperature-Inside Temperature)
Liquid layer temperature in dehumidification
​ LaTeX ​ Go Liquid layer temperature = Inside Temperature-(((Gas Phase Heat Transfer Coefficient*(Bulk Gas Temperature-Inside Temperature))+Enthalpy of Evaporation*Gas Phase Mass Transfer Coefficient*(Absolute Humidity of Air(tg)-Absolute Humidity (ti)))/Liquid Phase Heat Transfer Coefficient)
Convective mass transfer coefficient in humidification
​ LaTeX ​ Go Convective Mass Transfer Coefficient = (Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*(Partial Pressure-Partial Pressure in air))
Enthalpy of evaporation for water in humidification
​ LaTeX ​ Go Enthalpy of Evaporation = (Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Convective Mass Transfer Coefficient*(Partial Pressure-Partial Pressure in air))

Partial pressure of water vapor at wet bulb temperature Formula

​LaTeX ​Go
Partial Pressure = ((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))+Partial Pressure in air
Pw = ((hConv*(T∞-Tw))/(hfg*kL))+P∞

What is humidification...?

Humidification is the process in which the moisture or water vapor or humidity is added to the air. Common equipment used in this process is a humidifier. Dehumidification as the term suggests, is the opposite of humidification since dehumidification means removing the moisture from the air. Common equipment used in this process is a dehumidifier.
Humidity is the presence of water vapor or moisture in the air, while relative humidity, on the other hand, is the comparison of the actual moisture or water vapor in the air vs. the total water vapor or moisture that the air can handle.



How to Calculate Partial pressure of water vapor at wet bulb temperature?

Partial pressure of water vapor at wet bulb temperature calculator uses Partial Pressure = ((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))+Partial Pressure in air to calculate the Partial Pressure, The Partial pressure of water vapor at wet bulb temperature formula is defined as the pressure of the water vapor at wet bulb temerature. Partial Pressure is denoted by Pw symbol.

How to calculate Partial pressure of water vapor at wet bulb temperature using this online calculator? To use this online calculator for Partial pressure of water vapor at wet bulb temperature, enter Convective Heat Transfer Coefficient (hConv), Air Temperature (T∞), Wet Bulb Temperature (Tw), Enthalpy of Evaporation (hfg), Convective Mass Transfer Coefficient (kL) & Partial Pressure in air (P∞) and hit the calculate button. Here is how the Partial pressure of water vapor at wet bulb temperature calculation can be explained with given input values -> 13.83179 = ((0.5*(35-14))/(90*0.0095))+0.016.

FAQ

What is Partial pressure of water vapor at wet bulb temperature?
The Partial pressure of water vapor at wet bulb temperature formula is defined as the pressure of the water vapor at wet bulb temerature and is represented as Pw = ((hConv*(T∞-Tw))/(hfg*kL))+P∞ or Partial Pressure = ((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))+Partial Pressure in air. Convective Heat Transfer Coefficient is the heat transfer due to convection, Air temperature is the temperature of the air surrounding an individual and is typically measured in degrees Celsius (°C) or in Kelvin, Wet Bulb Temperature is the temperature of the wet bulb and denoted by the symbol Tw, Enthalpy of evaporation is the amount of energy (enthalpy) that must be added to a liquid substance to transform a quantity of that substance into a gas, Convective Mass Transfer Coefficient is a function of geometry of the system and the velocity and properties of the fluid similar to the heat transfer coefficient & Partial pressure in air of the water vapor is the pressure of water in the mixture of water and air.
How to calculate Partial pressure of water vapor at wet bulb temperature?
The Partial pressure of water vapor at wet bulb temperature formula is defined as the pressure of the water vapor at wet bulb temerature is calculated using Partial Pressure = ((Convective Heat Transfer Coefficient*(Air Temperature-Wet Bulb Temperature))/(Enthalpy of Evaporation*Convective Mass Transfer Coefficient))+Partial Pressure in air. To calculate Partial pressure of water vapor at wet bulb temperature, you need Convective Heat Transfer Coefficient (hConv), Air Temperature (T∞), Wet Bulb Temperature (Tw), Enthalpy of Evaporation (hfg), Convective Mass Transfer Coefficient (kL) & Partial Pressure in air (P∞). With our tool, you need to enter the respective value for Convective Heat Transfer Coefficient, Air Temperature, Wet Bulb Temperature, Enthalpy of Evaporation, Convective Mass Transfer Coefficient & Partial Pressure in air and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!