Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8 Solution

STEP 0: Pre-Calculation Summary
Formula Used
Oxygen Transfer Capacity = Oxygen Transferred/(((D.O Saturation when Correction Factor is 0.8-Operation Dissolved Oxygen)*0.8*(1.024)^(Temperature-20))/(9.17))
Ns = N/(((DO0.8-DL)*0.8*(1.024)^(T-20))/(9.17))
This formula uses 5 Variables
Variables Used
Oxygen Transfer Capacity - (Measured in Kilogram per Second per Watt) - Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Oxygen Transferred - (Measured in Kilogram per Second per Watt) - Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
D.O Saturation when Correction Factor is 0.8 - (Measured in Kilogram per Cubic Meter) - D.O Saturation when Correction Factor is 0.8 is the maximum concentration of dissolved oxygen, when the actual D.O. saturation level in sewage is 80% of the theoretical D.O. saturation level.
Operation Dissolved Oxygen - (Measured in Kilogram per Cubic Meter) - Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms.
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
STEP 1: Convert Input(s) to Base Unit
Oxygen Transferred: 3 Kilogram per Hour per Kilowatt --> 8.33333333333333E-07 Kilogram per Second per Watt (Check conversion ​here)
D.O Saturation when Correction Factor is 0.8: 3627.84 Milligram per Liter --> 3.62784 Kilogram per Cubic Meter (Check conversion ​here)
Operation Dissolved Oxygen: 2.01 Milligram per Liter --> 0.00201 Kilogram per Cubic Meter (Check conversion ​here)
Temperature: 85 Kelvin --> 85 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ns = N/(((DO0.8-DL)*0.8*(1.024)^(T-20))/(9.17)) --> 8.33333333333333E-07/(((3.62784-0.00201)*0.8*(1.024)^(85-20))/(9.17))
Evaluating ... ...
Ns = 5.63888818660015E-07
STEP 3: Convert Result to Output's Unit
5.63888818660015E-07 Kilogram per Second per Watt -->2.02999974717605 Kilogram per Hour per Kilowatt (Check conversion ​here)
FINAL ANSWER
2.02999974717605 2.03 Kilogram per Hour per Kilowatt <-- Oxygen Transfer Capacity
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Oxygen Transfer Capacity Calculators

Oxygen Transfer Capacity under Standard Conditions
​ Go Oxygen Transfer Capacity = Oxygen Transferred/(((Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under Field Conditions
​ Go Oxygen Transferred = (Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17)
Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen
​ Go Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under Field given Difference between Saturation and Operation Dissolved Oxygen
​ Go Oxygen Transferred = (Oxygen Transfer Capacity*Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)

Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8 Formula

Oxygen Transfer Capacity = Oxygen Transferred/(((D.O Saturation when Correction Factor is 0.8-Operation Dissolved Oxygen)*0.8*(1.024)^(Temperature-20))/(9.17))
Ns = N/(((DO0.8-DL)*0.8*(1.024)^(T-20))/(9.17))

What is Dissolved Oxygen?

Dissolved Oxygen is the amount of gaseous oxygen (O2) dissolved in the water. Oxygen enters the water by direct absorption from the atmosphere, by rapid movement, or as a waste product of plant photosynthesis. Water temperature and the volume of moving water can affect dissolved oxygen levels.

How to Calculate Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8?

Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8 calculator uses Oxygen Transfer Capacity = Oxygen Transferred/(((D.O Saturation when Correction Factor is 0.8-Operation Dissolved Oxygen)*0.8*(1.024)^(Temperature-20))/(9.17)) to calculate the Oxygen Transfer Capacity, The Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8 formula is defined as the calculation of the oxygen transfer capacity when we correction factor is 0.8. Oxygen Transfer Capacity is denoted by Ns symbol.

How to calculate Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8 using this online calculator? To use this online calculator for Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8, enter Oxygen Transferred (N), D.O Saturation when Correction Factor is 0.8 (DO0.8), Operation Dissolved Oxygen (DL) & Temperature (T) and hit the calculate button. Here is how the Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8 calculation can be explained with given input values -> 7.3E+6 = 8.33333333333333E-07/(((3.62784-0.00201)*0.8*(1.024)^(85-20))/(9.17)).

FAQ

What is Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8?
The Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8 formula is defined as the calculation of the oxygen transfer capacity when we correction factor is 0.8 and is represented as Ns = N/(((DO0.8-DL)*0.8*(1.024)^(T-20))/(9.17)) or Oxygen Transfer Capacity = Oxygen Transferred/(((D.O Saturation when Correction Factor is 0.8-Operation Dissolved Oxygen)*0.8*(1.024)^(Temperature-20))/(9.17)). Oxygen Transferred is the amount of oxygen that is moved from the air into the water, D.O Saturation when Correction Factor is 0.8 is the maximum concentration of dissolved oxygen, when the actual D.O. saturation level in sewage is 80% of the theoretical D.O. saturation level, Operation Dissolved Oxygen is the amount of oxygen that is present in water. It is a crucial parameter in assessing water quality because it is essential for the survival of aquatic organisms & Temperature is the degree or intensity of heat present in a substance or object.
How to calculate Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8?
The Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8 formula is defined as the calculation of the oxygen transfer capacity when we correction factor is 0.8 is calculated using Oxygen Transfer Capacity = Oxygen Transferred/(((D.O Saturation when Correction Factor is 0.8-Operation Dissolved Oxygen)*0.8*(1.024)^(Temperature-20))/(9.17)). To calculate Oxygen Transfer Capacity under Standard Conditions when Correction Factor is 0.8, you need Oxygen Transferred (N), D.O Saturation when Correction Factor is 0.8 (DO0.8), Operation Dissolved Oxygen (DL) & Temperature (T). With our tool, you need to enter the respective value for Oxygen Transferred, D.O Saturation when Correction Factor is 0.8, Operation Dissolved Oxygen & Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Oxygen Transfer Capacity?
In this formula, Oxygen Transfer Capacity uses Oxygen Transferred, D.O Saturation when Correction Factor is 0.8, Operation Dissolved Oxygen & Temperature. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Oxygen Transfer Capacity = Oxygen Transferred/(((Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17))
  • Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17))
  • Oxygen Transfer Capacity = Oxygen Transferred/(((D.O Saturation when Correction Factor is 0.85-Operation Dissolved Oxygen)*0.85*(1.024)^(Temperature-20))/(9.17))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!