Formula Used
Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Ns = N/((D*Cf*(1.024)^(T-20))/(9.17))
This formula uses 5 Variables
Variables Used
Oxygen Transfer Capacity - (Measured in Kilogram per Second per Watt) - Oxygen Transfer Capacity is the ability of a system, typically in a wastewater treatment context, to transfer oxygen from the air into the water.
Oxygen Transferred - (Measured in Kilogram per Second per Watt) - Oxygen Transferred is the amount of oxygen that is moved from the air into the water.
Difference between Saturation DO and Operation DO - (Measured in Kilogram per Cubic Meter) - Difference between Saturation DO and Operation DO is the value obtained after subtracting operation DO from saturation DO.
Correction Factor - Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error.
Temperature - (Measured in Kelvin) - Temperature is the degree or intensity of heat present in a substance or object.
STEP 1: Convert Input(s) to Base Unit
Oxygen Transferred: 3 Kilogram per Hour per Kilowatt --> 8.33333333333333E-07 Kilogram per Second per Watt (Check conversion ​here)
Difference between Saturation DO and Operation DO: 6600 Milligram per Liter --> 6.6 Kilogram per Cubic Meter (Check conversion ​here)
Correction Factor: 0.5 --> No Conversion Required
Temperature: 85 Kelvin --> 85 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ns = N/((D*Cf*(1.024)^(T-20))/(9.17)) --> 8.33333333333333E-07/((6.6*0.5*(1.024)^(85-20))/(9.17))
Evaluating ... ...
Ns = 4.95652120087768E-07
STEP 3: Convert Result to Output's Unit
4.95652120087768E-07 Kilogram per Second per Watt -->1.78434763231596 Kilogram per Hour per Kilowatt (Check conversion ​here)
FINAL ANSWER
1.78434763231596 1.784348 Kilogram per Hour per Kilowatt <-- Oxygen Transfer Capacity
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Oxygen Transfer Capacity Calculators

Oxygen Transfer Capacity under Standard Conditions
​ LaTeX ​ Go Oxygen Transfer Capacity = Oxygen Transferred/(((Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under Field Conditions
​ LaTeX ​ Go Oxygen Transferred = (Oxygen Transfer Capacity*(Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17)
Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen
​ LaTeX ​ Go Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Oxygen Transferred under Field given Difference between Saturation and Operation Dissolved Oxygen
​ LaTeX ​ Go Oxygen Transferred = (Oxygen Transfer Capacity*Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)

Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen Formula

​LaTeX ​Go
Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17))
Ns = N/((D*Cf*(1.024)^(T-20))/(9.17))

What is Dissolved Oxygen?

Dissolved Oxygen is the amount of gaseous oxygen (O2) dissolved in the water. Oxygen enters the water by direct absorption from the atmosphere, by rapid movement, or as a waste product of plant photosynthesis. Water temperature and the volume of moving water can affect dissolved oxygen levels.

How to Calculate Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen?

Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen calculator uses Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)) to calculate the Oxygen Transfer Capacity, The Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen formula is defined as the calculation of the oxygen transfer capacity when we have prior information of difference between saturation and operation dissolved oxygen. Oxygen Transfer Capacity is denoted by Ns symbol.

How to calculate Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen using this online calculator? To use this online calculator for Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen, enter Oxygen Transferred (N), Difference between Saturation DO and Operation DO (D), Correction Factor (Cf) & Temperature (T) and hit the calculate button. Here is how the Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen calculation can be explained with given input values -> 7.3E+6 = 8.33333333333333E-07/((6.6*0.5*(1.024)^(85-20))/(9.17)).

FAQ

What is Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen?
The Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen formula is defined as the calculation of the oxygen transfer capacity when we have prior information of difference between saturation and operation dissolved oxygen and is represented as Ns = N/((D*Cf*(1.024)^(T-20))/(9.17)) or Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)). Oxygen Transferred is the amount of oxygen that is moved from the air into the water, Difference between Saturation DO and Operation DO is the value obtained after subtracting operation DO from saturation DO, Correction Factor is that which is multiplied with the result of an equation to correct for a known amount of systematic error & Temperature is the degree or intensity of heat present in a substance or object.
How to calculate Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen?
The Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen formula is defined as the calculation of the oxygen transfer capacity when we have prior information of difference between saturation and operation dissolved oxygen is calculated using Oxygen Transfer Capacity = Oxygen Transferred/((Difference between Saturation DO and Operation DO*Correction Factor*(1.024)^(Temperature-20))/(9.17)). To calculate Oxygen Transfer Capacity given Difference between Saturation and Operation Dissolved Oxygen, you need Oxygen Transferred (N), Difference between Saturation DO and Operation DO (D), Correction Factor (Cf) & Temperature (T). With our tool, you need to enter the respective value for Oxygen Transferred, Difference between Saturation DO and Operation DO, Correction Factor & Temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Oxygen Transfer Capacity?
In this formula, Oxygen Transfer Capacity uses Oxygen Transferred, Difference between Saturation DO and Operation DO, Correction Factor & Temperature. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Oxygen Transfer Capacity = Oxygen Transferred/(((Dissolved Oxygen Saturation-Operation Dissolved Oxygen)*Correction Factor*(1.024)^(Temperature-20))/(9.17))
  • Oxygen Transfer Capacity = Oxygen Transferred/(((D.O Saturation when Correction Factor is 0.8-Operation Dissolved Oxygen)*0.8*(1.024)^(Temperature-20))/(9.17))
  • Oxygen Transfer Capacity = Oxygen Transferred/(((D.O Saturation when Correction Factor is 0.85-Operation Dissolved Oxygen)*0.85*(1.024)^(Temperature-20))/(9.17))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!