Oxygen Equivalent given Log value of Critical Oxygen Deficit Solution

STEP 0: Pre-Calculation Summary
Formula Used
Oxygen Equivalent = Self-Purification Constant*10^(log10(Critical Oxygen Deficit)+(Deoxygenation Constant*Critical Time))
Lt = f*10^(log10(Dc)+(KD*tc))
This formula uses 1 Functions, 5 Variables
Functions Used
log10 - The common logarithm, also known as the base-10 logarithm or the decimal logarithm, is a mathematical function that is the inverse of the exponential function., log10(Number)
Variables Used
Oxygen Equivalent - (Measured in Kilogram per Cubic Meter) - The Oxygen Equivalent is referred as the oxidizable organic matter present in sewage.
Self-Purification Constant - Self-Purification Constant is referred as the ratio of reoxygenation constant to deoxygenation constant.
Critical Oxygen Deficit - Critical Oxygen Deficit is referred as the condition where the deoxygenation rate exceeds the reoxygenation rate.
Deoxygenation Constant - (Measured in 1 Per Second) - Deoxygenation Constant is referred as the value obtained after decomposing of oxygen in sewage.
Critical Time - (Measured in Second) - Critical Time refers to the minimum dissolved oxygen concentration occurs, found by differentiating the dissolved oxygen equation with respect to time.
STEP 1: Convert Input(s) to Base Unit
Self-Purification Constant: 0.9 --> No Conversion Required
Critical Oxygen Deficit: 0.0003 --> No Conversion Required
Deoxygenation Constant: 0.23 1 Per Day --> 2.66203703703704E-06 1 Per Second (Check conversion ​here)
Critical Time: 0.5 Day --> 43200 Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Lt = f*10^(log10(Dc)+(KD*tc)) --> 0.9*10^(log10(0.0003)+(2.66203703703704E-06*43200))
Evaluating ... ...
Lt = 0.000351855030182121
STEP 3: Convert Result to Output's Unit
0.000351855030182121 Kilogram per Cubic Meter -->0.351855030182121 Milligram per Liter (Check conversion ​here)
FINAL ANSWER
0.351855030182121 0.351855 Milligram per Liter <-- Oxygen Equivalent
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has verified this Calculator and 500+ more calculators!

Oxygen Equivalent Calculators

Oxygen Equivalent given Critical Time in Self Purification Factor
​ LaTeX ​ Go Oxygen Equivalent = Critical Oxygen Deficit*(Self-Purification Constant-1)/(1-((10^(Critical Time*Deoxygenation Constant*(Self-Purification Constant-1)))/Self-Purification Constant))
Oxygen Equivalent given Critical Oxygen Deficit
​ LaTeX ​ Go Oxygen Equivalent = Critical Oxygen Deficit*Reoxygenation Coefficient/(Deoxygenation Constant*10^(-Deoxygenation Constant*Critical Time))
Oxygen Equivalent given Log value of Critical Oxygen Deficit
​ LaTeX ​ Go Oxygen Equivalent = Self-Purification Constant*10^(log10(Critical Oxygen Deficit)+(Deoxygenation Constant*Critical Time))
Oxygen Equivalent given Self Purification Constant with Critical Oxygen Deficit
​ LaTeX ​ Go Oxygen Equivalent = Critical Oxygen Deficit*Self-Purification Constant/(10^(-Deoxygenation Constant*Critical Time))

Oxygen Equivalent given Log value of Critical Oxygen Deficit Formula

​LaTeX ​Go
Oxygen Equivalent = Self-Purification Constant*10^(log10(Critical Oxygen Deficit)+(Deoxygenation Constant*Critical Time))
Lt = f*10^(log10(Dc)+(KD*tc))

What is Critical Oxygen Deficit?

The Critical Oxygen Deficit is the condition where the deoxygenation rate exceeds the reoxygenation rate.

How to Calculate Oxygen Equivalent given Log value of Critical Oxygen Deficit?

Oxygen Equivalent given Log value of Critical Oxygen Deficit calculator uses Oxygen Equivalent = Self-Purification Constant*10^(log10(Critical Oxygen Deficit)+(Deoxygenation Constant*Critical Time)) to calculate the Oxygen Equivalent, The Oxygen Equivalent given Log value of Critical Oxygen Deficit formula is defined as the amount of oxygen equivalents consumed in chemical oxidation of organic matter by strong oxidant. Oxygen Equivalent is denoted by Lt symbol.

How to calculate Oxygen Equivalent given Log value of Critical Oxygen Deficit using this online calculator? To use this online calculator for Oxygen Equivalent given Log value of Critical Oxygen Deficit, enter Self-Purification Constant (f), Critical Oxygen Deficit (Dc), Deoxygenation Constant (KD) & Critical Time (tc) and hit the calculate button. Here is how the Oxygen Equivalent given Log value of Critical Oxygen Deficit calculation can be explained with given input values -> 234.57 = 0.9*10^(log10(0.0003)+(2.66203703703704E-06*43200)).

FAQ

What is Oxygen Equivalent given Log value of Critical Oxygen Deficit?
The Oxygen Equivalent given Log value of Critical Oxygen Deficit formula is defined as the amount of oxygen equivalents consumed in chemical oxidation of organic matter by strong oxidant and is represented as Lt = f*10^(log10(Dc)+(KD*tc)) or Oxygen Equivalent = Self-Purification Constant*10^(log10(Critical Oxygen Deficit)+(Deoxygenation Constant*Critical Time)). Self-Purification Constant is referred as the ratio of reoxygenation constant to deoxygenation constant, Critical Oxygen Deficit is referred as the condition where the deoxygenation rate exceeds the reoxygenation rate, Deoxygenation Constant is referred as the value obtained after decomposing of oxygen in sewage & Critical Time refers to the minimum dissolved oxygen concentration occurs, found by differentiating the dissolved oxygen equation with respect to time.
How to calculate Oxygen Equivalent given Log value of Critical Oxygen Deficit?
The Oxygen Equivalent given Log value of Critical Oxygen Deficit formula is defined as the amount of oxygen equivalents consumed in chemical oxidation of organic matter by strong oxidant is calculated using Oxygen Equivalent = Self-Purification Constant*10^(log10(Critical Oxygen Deficit)+(Deoxygenation Constant*Critical Time)). To calculate Oxygen Equivalent given Log value of Critical Oxygen Deficit, you need Self-Purification Constant (f), Critical Oxygen Deficit (Dc), Deoxygenation Constant (KD) & Critical Time (tc). With our tool, you need to enter the respective value for Self-Purification Constant, Critical Oxygen Deficit, Deoxygenation Constant & Critical Time and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Oxygen Equivalent?
In this formula, Oxygen Equivalent uses Self-Purification Constant, Critical Oxygen Deficit, Deoxygenation Constant & Critical Time. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Oxygen Equivalent = Critical Oxygen Deficit*Reoxygenation Coefficient/(Deoxygenation Constant*10^(-Deoxygenation Constant*Critical Time))
  • Oxygen Equivalent = Critical Oxygen Deficit*Self-Purification Constant/(10^(-Deoxygenation Constant*Critical Time))
  • Oxygen Equivalent = Critical Oxygen Deficit*(Self-Purification Constant-1)/(1-((10^(Critical Time*Deoxygenation Constant*(Self-Purification Constant-1)))/Self-Purification Constant))