Output Switching at Load Power Consumption Solution

STEP 0: Pre-Calculation Summary
Formula Used
Output Switching = Capacitive Load Power Consumption/(External Load Capacitance*Supply Voltage^2*Output Signal Frequency)
Swo = PL/(CL*Vcc^2*fo)
This formula uses 5 Variables
Variables Used
Output Switching - Output switching defined as number of bits changed when switching is done in the whole process and calculated accordingly for the finding out the total output switching.
Capacitive Load Power Consumption - (Measured in Watt) - The Capacitive Load Power Consumption is to calculate the power consumption of the capacitor.
External Load Capacitance - (Measured in Farad) - The External Load Capacitance is calculated by the load capacitor(which is connected outside the circuit) of a circuit.
Supply Voltage - (Measured in Volt) - The Supply voltage is the voltage input.
Output Signal Frequency - (Measured in Hertz) - The Output Signal Frequency is calculated by taking frequency at the output of the signal.
STEP 1: Convert Input(s) to Base Unit
Capacitive Load Power Consumption: 2.94 Milliwatt --> 0.00294 Watt (Check conversion ​here)
External Load Capacitance: 5.01 Microfarad --> 5.01E-06 Farad (Check conversion ​here)
Supply Voltage: 1.55 Volt --> 1.55 Volt No Conversion Required
Output Signal Frequency: 61 Hertz --> 61 Hertz No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Swo = PL/(CL*Vcc^2*fo) --> 0.00294/(5.01E-06*1.55^2*61)
Evaluating ... ...
Swo = 4.00420564170102
STEP 3: Convert Result to Output's Unit
4.00420564170102 --> No Conversion Required
FINAL ANSWER
4.00420564170102 4.004206 <-- Output Switching
(Calculation completed in 00.007 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

CMOS Power Metrics Calculators

Activity Factor
​ LaTeX ​ Go Activity Factor = Switching Power/(Capacitance*Base Collector Voltage^2*Frequency)
Switching Power
​ LaTeX ​ Go Switching Power = Activity Factor*(Capacitance*Base Collector Voltage^2*Frequency)
Short-Circuit Power in CMOS
​ LaTeX ​ Go Short-Circuit Power = Dynamic Power-Switching Power
Dynamic Power in CMOS
​ LaTeX ​ Go Dynamic Power = Short-Circuit Power+Switching Power

Output Switching at Load Power Consumption Formula

​LaTeX ​Go
Output Switching = Capacitive Load Power Consumption/(External Load Capacitance*Supply Voltage^2*Output Signal Frequency)
Swo = PL/(CL*Vcc^2*fo)

What is minimum energy under a delay constraint?

The power consumption of the system is limited by battery or cooling considerations. This makes the designer seeks to achieve minimum delay under an power energy constraint.

How to Calculate Output Switching at Load Power Consumption?

Output Switching at Load Power Consumption calculator uses Output Switching = Capacitive Load Power Consumption/(External Load Capacitance*Supply Voltage^2*Output Signal Frequency) to calculate the Output Switching, Output Switching at Load Power Consumption refers to the ability of a power load to switch between different electrical outputs based on the load's power requirements. Output Switching is denoted by Swo symbol.

How to calculate Output Switching at Load Power Consumption using this online calculator? To use this online calculator for Output Switching at Load Power Consumption, enter Capacitive Load Power Consumption (PL), External Load Capacitance (CL), Supply Voltage (Vcc) & Output Signal Frequency (fo) and hit the calculate button. Here is how the Output Switching at Load Power Consumption calculation can be explained with given input values -> 4.004206 = 0.00294/(5.01E-06*1.55^2*61).

FAQ

What is Output Switching at Load Power Consumption?
Output Switching at Load Power Consumption refers to the ability of a power load to switch between different electrical outputs based on the load's power requirements and is represented as Swo = PL/(CL*Vcc^2*fo) or Output Switching = Capacitive Load Power Consumption/(External Load Capacitance*Supply Voltage^2*Output Signal Frequency). The Capacitive Load Power Consumption is to calculate the power consumption of the capacitor, The External Load Capacitance is calculated by the load capacitor(which is connected outside the circuit) of a circuit, The Supply voltage is the voltage input & The Output Signal Frequency is calculated by taking frequency at the output of the signal.
How to calculate Output Switching at Load Power Consumption?
Output Switching at Load Power Consumption refers to the ability of a power load to switch between different electrical outputs based on the load's power requirements is calculated using Output Switching = Capacitive Load Power Consumption/(External Load Capacitance*Supply Voltage^2*Output Signal Frequency). To calculate Output Switching at Load Power Consumption, you need Capacitive Load Power Consumption (PL), External Load Capacitance (CL), Supply Voltage (Vcc) & Output Signal Frequency (fo). With our tool, you need to enter the respective value for Capacitive Load Power Consumption, External Load Capacitance, Supply Voltage & Output Signal Frequency and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!