Output Resistance of Signal Generator Solution

STEP 0: Pre-Calculation Summary
Formula Used
Output Resistance of Signal Generator = (Gain of NRPA*Signal Frequency*Total Series Resistance at Signal Frequency*Total Series Resistance at Idler Frequency*(1-Ratio Negative Resistance to Series Resistance)^2)/(4*Signal Frequency*Output Resistance of Idler Generator*Ratio Negative Resistance to Series Resistance)
Rg = (GNRPA*fs*RTs*RTi*(1-α)^2)/(4*fs*Ri*α)
This formula uses 7 Variables
Variables Used
Output Resistance of Signal Generator - (Measured in Ohm) - Output Resistance of Signal Generator is a key operating parameter that controls the current generation signal generator when used as a power source.
Gain of NRPA - (Measured in Decibel) - Gain of NRPA (Negative Resistance Parametric Amplifier) is proportional to the negative resistance generated by the LC circuit in an Parametric Amplifier.
Signal Frequency - (Measured in Hertz) - Signal frequency is defined as the frequency of a signal that is containing information.
Total Series Resistance at Signal Frequency - (Measured in Ohm) - Total series resistance at signal frequency is the sum of all resistances in series that are present in a circuit at the frequency of the signal.
Total Series Resistance at Idler Frequency - (Measured in Ohm) - Total Series Resistance at Idler Frequency as the total resistance of pumping frequency observed.
Ratio Negative Resistance to Series Resistance - Ratio negative resistance to series resistance is denoted by a symbol.
Output Resistance of Idler Generator - (Measured in Ohm) - Output resistance of idler generator is resistance observed at the output of the load.
STEP 1: Convert Input(s) to Base Unit
Gain of NRPA: 15.6 Decibel --> 15.6 Decibel No Conversion Required
Signal Frequency: 95 Hertz --> 95 Hertz No Conversion Required
Total Series Resistance at Signal Frequency: 7.8 Ohm --> 7.8 Ohm No Conversion Required
Total Series Resistance at Idler Frequency: 10 Ohm --> 10 Ohm No Conversion Required
Ratio Negative Resistance to Series Resistance: 9 --> No Conversion Required
Output Resistance of Idler Generator: 65 Ohm --> 65 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rg = (GNRPA*fs*RTs*RTi*(1-α)^2)/(4*fs*Ri*α) --> (15.6*95*7.8*10*(1-9)^2)/(4*95*65*9)
Evaluating ... ...
Rg = 33.28
STEP 3: Convert Result to Output's Unit
33.28 Ohm --> No Conversion Required
FINAL ANSWER
33.28 Ohm <-- Output Resistance of Signal Generator
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Parametric Devices Calculators

Power Gain for Parametric Up-Converter
​ LaTeX ​ Go Power Gain for Up-Converter = (Output Frequency/Signal Frequency)*Gain Degradation Factor
Gain-Degradation Factor
​ LaTeX ​ Go Gain Degradation Factor = (Signal Frequency/Output Frequency)*Power Gain for Up-Converter
Power Gain of Demodulator
​ LaTeX ​ Go Power Gain of Demodulator = Signal Frequency/(Pumping Frequency+Signal Frequency)
Power Gain of Modulator
​ LaTeX ​ Go Power Gain of Modulator = (Pumping Frequency+Signal Frequency)/Signal Frequency

Output Resistance of Signal Generator Formula

​LaTeX ​Go
Output Resistance of Signal Generator = (Gain of NRPA*Signal Frequency*Total Series Resistance at Signal Frequency*Total Series Resistance at Idler Frequency*(1-Ratio Negative Resistance to Series Resistance)^2)/(4*Signal Frequency*Output Resistance of Idler Generator*Ratio Negative Resistance to Series Resistance)
Rg = (GNRPA*fs*RTs*RTi*(1-α)^2)/(4*fs*Ri*α)

What Is Hybrid Couplers?

Hybrid couplers are interdigitated microstrip couplers consisting of four parallel striplines with alternate lines tied together. Hybrid couplers are frequently used as components in microwave systems or subsystems such as attenuators, balanced amplifiers, balanced mixers, modulators, discriminators, and phase shifters.

How to Calculate Output Resistance of Signal Generator?

Output Resistance of Signal Generator calculator uses Output Resistance of Signal Generator = (Gain of NRPA*Signal Frequency*Total Series Resistance at Signal Frequency*Total Series Resistance at Idler Frequency*(1-Ratio Negative Resistance to Series Resistance)^2)/(4*Signal Frequency*Output Resistance of Idler Generator*Ratio Negative Resistance to Series Resistance) to calculate the Output Resistance of Signal Generator, The Output Resistance of Signal Generator formula is defined as total output resistance at signal frequency is the sum of all resistances in series that are present in a circuit at the frequency of the signal. Output Resistance of Signal Generator is denoted by Rg symbol.

How to calculate Output Resistance of Signal Generator using this online calculator? To use this online calculator for Output Resistance of Signal Generator, enter Gain of NRPA (GNRPA), Signal Frequency (fs), Total Series Resistance at Signal Frequency (RTs), Total Series Resistance at Idler Frequency (RTi), Ratio Negative Resistance to Series Resistance (α) & Output Resistance of Idler Generator (Ri) and hit the calculate button. Here is how the Output Resistance of Signal Generator calculation can be explained with given input values -> 33.28 = (15.6*95*7.8*10*(1-9)^2)/(4*95*65*9).

FAQ

What is Output Resistance of Signal Generator?
The Output Resistance of Signal Generator formula is defined as total output resistance at signal frequency is the sum of all resistances in series that are present in a circuit at the frequency of the signal and is represented as Rg = (GNRPA*fs*RTs*RTi*(1-α)^2)/(4*fs*Ri*α) or Output Resistance of Signal Generator = (Gain of NRPA*Signal Frequency*Total Series Resistance at Signal Frequency*Total Series Resistance at Idler Frequency*(1-Ratio Negative Resistance to Series Resistance)^2)/(4*Signal Frequency*Output Resistance of Idler Generator*Ratio Negative Resistance to Series Resistance). Gain of NRPA (Negative Resistance Parametric Amplifier) is proportional to the negative resistance generated by the LC circuit in an Parametric Amplifier, Signal frequency is defined as the frequency of a signal that is containing information, Total series resistance at signal frequency is the sum of all resistances in series that are present in a circuit at the frequency of the signal, Total Series Resistance at Idler Frequency as the total resistance of pumping frequency observed, Ratio negative resistance to series resistance is denoted by a symbol & Output resistance of idler generator is resistance observed at the output of the load.
How to calculate Output Resistance of Signal Generator?
The Output Resistance of Signal Generator formula is defined as total output resistance at signal frequency is the sum of all resistances in series that are present in a circuit at the frequency of the signal is calculated using Output Resistance of Signal Generator = (Gain of NRPA*Signal Frequency*Total Series Resistance at Signal Frequency*Total Series Resistance at Idler Frequency*(1-Ratio Negative Resistance to Series Resistance)^2)/(4*Signal Frequency*Output Resistance of Idler Generator*Ratio Negative Resistance to Series Resistance). To calculate Output Resistance of Signal Generator, you need Gain of NRPA (GNRPA), Signal Frequency (fs), Total Series Resistance at Signal Frequency (RTs), Total Series Resistance at Idler Frequency (RTi), Ratio Negative Resistance to Series Resistance (α) & Output Resistance of Idler Generator (Ri). With our tool, you need to enter the respective value for Gain of NRPA, Signal Frequency, Total Series Resistance at Signal Frequency, Total Series Resistance at Idler Frequency, Ratio Negative Resistance to Series Resistance & Output Resistance of Idler Generator and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!