Organic Loading to Trickling Filter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length))
OL = (BOD5/(A*Lf))
This formula uses 4 Variables
Variables Used
Organic Loading - (Measured in Kilogram per Second Square Meter) - Organic Loading is the amount of organic material, typically measured in kilograms per day per cubic meter that is applied to the filter bed for biological treatment of wastewater.
BOD Loading to Filter - (Measured in Kilogram per Second) - BOD Loading to Filter is the amount of biochemical oxygen demand applied to a filtration system, typically expressed in terms of mass per unit area or volume.
Area of Filter - (Measured in Square Meter) - The Area of Filter refers to the total surface available for filtration, affecting its capacity and efficiency, typically measured in square meters (m²).
Filter Length - (Measured in Meter) - The Filter Length refers to the total length of filter required to effectively do the filtering process.
STEP 1: Convert Input(s) to Base Unit
BOD Loading to Filter: 225 Kilogram per Day --> 0.00260416666666667 Kilogram per Second (Check conversion ​here)
Area of Filter: 3 Square Meter --> 3 Square Meter No Conversion Required
Filter Length: 2.5 Meter --> 2.5 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
OL = (BOD5/(A*Lf)) --> (0.00260416666666667/(3*2.5))
Evaluating ... ...
OL = 0.000347222222222223
STEP 3: Convert Result to Output's Unit
0.000347222222222223 Kilogram per Second Square Meter -->30 kilogram per Day Square Meter (Check conversion ​here)
FINAL ANSWER
30 kilogram per Day Square Meter <-- Organic Loading
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Organic Loading Calculators

Organic Loading to Trickling Filter
​ LaTeX ​ Go Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length))
Area of Filter given Organic Loading
​ LaTeX ​ Go Area of Filter = BOD Loading to Filter/(Organic Loading*Filter Length)
Filter Length given Organic Loading
​ LaTeX ​ Go Filter Length = BOD Loading to Filter/(Organic Loading*Area of Filter)
BOD Load given Organic Loading
​ LaTeX ​ Go BOD Loading to Filter = Organic Loading*Area of Filter*Filter Length

Organic Loading to Trickling Filter Formula

​LaTeX ​Go
Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length))
OL = (BOD5/(A*Lf))

What is Organic Loading ?

Organic loading rate is defined as the application of soluble and particulate organic matter. It is typically expressed on an area basis as pounds of BOD5 per unit area per unit time, such as pounds of BOD5 per square foot per day (lb/ft2/day).

How to Calculate Organic Loading to Trickling Filter?

Organic Loading to Trickling Filter calculator uses Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length)) to calculate the Organic Loading, The Organic Loading to Trickling Filter is defined as the rate at which organic matter is applied to a trickling filter, typically measured in kilograms per cubic meter per day (kg/m³/day) or other suitable unit. Organic Loading is denoted by OL symbol.

How to calculate Organic Loading to Trickling Filter using this online calculator? To use this online calculator for Organic Loading to Trickling Filter, enter BOD Loading to Filter (BOD5), Area of Filter (A) & Filter Length (Lf) and hit the calculate button. Here is how the Organic Loading to Trickling Filter calculation can be explained with given input values -> 2.2E+6 = (0.00260416666666667/(3*2.5)).

FAQ

What is Organic Loading to Trickling Filter?
The Organic Loading to Trickling Filter is defined as the rate at which organic matter is applied to a trickling filter, typically measured in kilograms per cubic meter per day (kg/m³/day) or other suitable unit and is represented as OL = (BOD5/(A*Lf)) or Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length)). BOD Loading to Filter is the amount of biochemical oxygen demand applied to a filtration system, typically expressed in terms of mass per unit area or volume, The Area of Filter refers to the total surface available for filtration, affecting its capacity and efficiency, typically measured in square meters (m²) & The Filter Length refers to the total length of filter required to effectively do the filtering process.
How to calculate Organic Loading to Trickling Filter?
The Organic Loading to Trickling Filter is defined as the rate at which organic matter is applied to a trickling filter, typically measured in kilograms per cubic meter per day (kg/m³/day) or other suitable unit is calculated using Organic Loading = (BOD Loading to Filter/(Area of Filter*Filter Length)). To calculate Organic Loading to Trickling Filter, you need BOD Loading to Filter (BOD5), Area of Filter (A) & Filter Length (Lf). With our tool, you need to enter the respective value for BOD Loading to Filter, Area of Filter & Filter Length and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!