Optical Attenuation Solution

STEP 0: Pre-Calculation Summary
Formula Used
Attenuation Per Unit Length = 10/(Length Of Cable-Cut Length)*log10(Photoreceiver Voltage At Cut Length/Photoreceiver Voltage At Full Length)
αdB = 10/(L1-L2)*log10(V2/V1)
This formula uses 1 Functions, 5 Variables
Functions Used
log10 - The common logarithm, also known as the base-10 logarithm or the decimal logarithm, is a mathematical function that is the inverse of the exponential function., log10(Number)
Variables Used
Attenuation Per Unit Length - (Measured in Decibel per Meter) - Attenuation Per Unit Length is defined as the rate at which the intensity of light or any electromagnetic wave decreases as it propagates through a medium.
Length Of Cable - (Measured in Meter) - Length Of Cable is the usually the measurement used to measure how long the cable is.
Cut Length - (Measured in Meter) - Cut Length is the measurement of fiber length which is cut.
Photoreceiver Voltage At Cut Length - (Measured in Volt) - Photoreceiver Voltage At Cut Length is the voltage measured at receiver side when the fiber length is cut.
Photoreceiver Voltage At Full Length - (Measured in Volt) - Photoreceiver Voltage At Full Length is the voltage at the receiver side when the length of the fiber is maximum.
STEP 1: Convert Input(s) to Base Unit
Length Of Cable: 2.01 Meter --> 2.01 Meter No Conversion Required
Cut Length: 2 Meter --> 2 Meter No Conversion Required
Photoreceiver Voltage At Cut Length: 2.2 Volt --> 2.2 Volt No Conversion Required
Photoreceiver Voltage At Full Length: 2.1 Volt --> 2.1 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
αdB = 10/(L1-L2)*log10(V2/V1) --> 10/(2.01-2)*log10(2.2/2.1)
Evaluating ... ...
αdB = 20.2033860882874
STEP 3: Convert Result to Output's Unit
20.2033860882874 Decibel per Meter --> No Conversion Required
FINAL ANSWER
20.2033860882874 20.20339 Decibel per Meter <-- Attenuation Per Unit Length
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Santhosh Yadav
Dayananda Sagar College Of Engineering (DSCE), Banglore
Santhosh Yadav has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Ritwik Tripathi
Vellore Institute of Technology (VIT Vellore), Vellore
Ritwik Tripathi has verified this Calculator and 100+ more calculators!

Transmission Measurements Calculators

Time Constant of Calorimeter
​ Go Time Constant = (Time Instance 2-Time Instance 1)/(ln(Maximum Temperature Rise-Temperature At Time t1)-ln(Maximum Temperature Rise-Temperature At Time t2))
Optical Attenuation
​ Go Attenuation Per Unit Length = 10/(Length Of Cable-Cut Length)*log10(Photoreceiver Voltage At Cut Length/Photoreceiver Voltage At Full Length)
Absorption Loss
​ Go Absorption Loss = (Thermal Capacity*Maximum Temperature Rise)/(Optical Power*Time Constant)
Scattering Loss
​ Go Scattering Loss = ((4.343*10^5)/Fiber Length)*(Constant Output Optical Power/Output Optical Power)

Optical Attenuation Formula

Attenuation Per Unit Length = 10/(Length Of Cable-Cut Length)*log10(Photoreceiver Voltage At Cut Length/Photoreceiver Voltage At Full Length)
αdB = 10/(L1-L2)*log10(V2/V1)

Why is Attenuation important?

Attenuation per unit length is important in optics because it helps us understand how light weakens as it travels through different materials. This knowledge is vital for designing optical systems, such as fiber optics for data transmission and medical imaging devices, where maintaining light intensity is crucial.

How to Calculate Optical Attenuation?

Optical Attenuation calculator uses Attenuation Per Unit Length = 10/(Length Of Cable-Cut Length)*log10(Photoreceiver Voltage At Cut Length/Photoreceiver Voltage At Full Length) to calculate the Attenuation Per Unit Length, Optical Attenuation per unit length is the rate at which light intensity decreases as it propagates through a medium. This attenuation can occur due to various factors, including absorption, scattering, and other interactions with the medium. Attenuation Per Unit Length is denoted by αdB symbol.

How to calculate Optical Attenuation using this online calculator? To use this online calculator for Optical Attenuation, enter Length Of Cable (L1), Cut Length (L2), Photoreceiver Voltage At Cut Length (V2) & Photoreceiver Voltage At Full Length (V1) and hit the calculate button. Here is how the Optical Attenuation calculation can be explained with given input values -> 20.20339 = 10/(2.01-2)*log10(2.2/2.1).

FAQ

What is Optical Attenuation?
Optical Attenuation per unit length is the rate at which light intensity decreases as it propagates through a medium. This attenuation can occur due to various factors, including absorption, scattering, and other interactions with the medium and is represented as αdB = 10/(L1-L2)*log10(V2/V1) or Attenuation Per Unit Length = 10/(Length Of Cable-Cut Length)*log10(Photoreceiver Voltage At Cut Length/Photoreceiver Voltage At Full Length). Length Of Cable is the usually the measurement used to measure how long the cable is, Cut Length is the measurement of fiber length which is cut, Photoreceiver Voltage At Cut Length is the voltage measured at receiver side when the fiber length is cut & Photoreceiver Voltage At Full Length is the voltage at the receiver side when the length of the fiber is maximum.
How to calculate Optical Attenuation?
Optical Attenuation per unit length is the rate at which light intensity decreases as it propagates through a medium. This attenuation can occur due to various factors, including absorption, scattering, and other interactions with the medium is calculated using Attenuation Per Unit Length = 10/(Length Of Cable-Cut Length)*log10(Photoreceiver Voltage At Cut Length/Photoreceiver Voltage At Full Length). To calculate Optical Attenuation, you need Length Of Cable (L1), Cut Length (L2), Photoreceiver Voltage At Cut Length (V2) & Photoreceiver Voltage At Full Length (V1). With our tool, you need to enter the respective value for Length Of Cable, Cut Length, Photoreceiver Voltage At Cut Length & Photoreceiver Voltage At Full Length and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!