Number of turns per unit length of magnetic coil Solution

STEP 0: Pre-Calculation Summary
Formula Used
Number of Turns per Unit Coil Length = Half Length Apparent Magnetic Force/Half Length Coil Current
n = H2/IL/2
This formula uses 3 Variables
Variables Used
Number of Turns per Unit Coil Length - Number of Turns per Unit Coil Length refers to the ratio of the total coil turns to its length, determining the coil's magnetic field strength per unit distance.
Half Length Apparent Magnetic Force - (Measured in Ampere per Meter) - Half Length Apparent Magnetic Force is the product of Number of Turns of a coil and Current in the coil when the length is half of its full length.
Half Length Coil Current - (Measured in Ampere) - Half Length Coil Current is the electric current flowing through a wire coil, generating a magnetic field around it. It is fundamental in electromagnets, transformers, and inductors.
STEP 1: Convert Input(s) to Base Unit
Half Length Apparent Magnetic Force: 16.8 Ampere per Meter --> 16.8 Ampere per Meter No Conversion Required
Half Length Coil Current: 4.2 Ampere --> 4.2 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
n = H2/IL/2 --> 16.8/4.2
Evaluating ... ...
n = 4
STEP 3: Convert Result to Output's Unit
4 --> No Conversion Required
FINAL ANSWER
4 <-- Number of Turns per Unit Coil Length
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Magnetic Instruments Calculators

Number of Turns in Solenoid
​ LaTeX ​ Go Number of Coil Turn = (Solenoid Magnetic Field*Solenoid Length)/(Electric Current*[Permeability-vacuum])
Magnetic Field of Solenoid
​ LaTeX ​ Go Solenoid Magnetic Field = ([Permeability-vacuum]*Number of Coil Turn*Electric Current)/Solenoid Length
Reluctance of Magnetic Circuit
​ LaTeX ​ Go Magnetic Circuit Reluctance = Magnetomotive Force/Magnetic Flux
Magneto Motive Force(MMF)
​ LaTeX ​ Go Magnetomotive Force = Magnetic Flux*Magnetic Circuit Reluctance

Number of turns per unit length of magnetic coil Formula

​LaTeX ​Go
Number of Turns per Unit Coil Length = Half Length Apparent Magnetic Force/Half Length Coil Current
n = H2/IL/2

Why two magnetic field lines never intersect each other?

The magnetic lines of force do not intersect (or cross) one another. If they do so then at the point of intersection, two tangents can be drawn at that point which indicates that there will be two different directions of the same magnetic field, i.e. the compass needle points in two different directions which is not possible.

How to Calculate Number of turns per unit length of magnetic coil?

Number of turns per unit length of magnetic coil calculator uses Number of Turns per Unit Coil Length = Half Length Apparent Magnetic Force/Half Length Coil Current to calculate the Number of Turns per Unit Coil Length, number of turns per unit length of magnetic coil formula is defined as is given for both total numbers of turns and turns per volts. Turns per volts formula is derived as (1/(4.44 x F x M x A)) where F = Operating frequency, M = Magnetic flux and A = Area of core. total number of turns formula is defined as ( Turns per volts x voltage). Number of Turns per Unit Coil Length is denoted by n symbol.

How to calculate Number of turns per unit length of magnetic coil using this online calculator? To use this online calculator for Number of turns per unit length of magnetic coil, enter Half Length Apparent Magnetic Force (H2) & Half Length Coil Current (IL/2) and hit the calculate button. Here is how the Number of turns per unit length of magnetic coil calculation can be explained with given input values -> 1.47619 = 16.8/4.2.

FAQ

What is Number of turns per unit length of magnetic coil?
number of turns per unit length of magnetic coil formula is defined as is given for both total numbers of turns and turns per volts. Turns per volts formula is derived as (1/(4.44 x F x M x A)) where F = Operating frequency, M = Magnetic flux and A = Area of core. total number of turns formula is defined as ( Turns per volts x voltage) and is represented as n = H2/IL/2 or Number of Turns per Unit Coil Length = Half Length Apparent Magnetic Force/Half Length Coil Current. Half Length Apparent Magnetic Force is the product of Number of Turns of a coil and Current in the coil when the length is half of its full length & Half Length Coil Current is the electric current flowing through a wire coil, generating a magnetic field around it. It is fundamental in electromagnets, transformers, and inductors.
How to calculate Number of turns per unit length of magnetic coil?
number of turns per unit length of magnetic coil formula is defined as is given for both total numbers of turns and turns per volts. Turns per volts formula is derived as (1/(4.44 x F x M x A)) where F = Operating frequency, M = Magnetic flux and A = Area of core. total number of turns formula is defined as ( Turns per volts x voltage) is calculated using Number of Turns per Unit Coil Length = Half Length Apparent Magnetic Force/Half Length Coil Current. To calculate Number of turns per unit length of magnetic coil, you need Half Length Apparent Magnetic Force (H2) & Half Length Coil Current (IL/2). With our tool, you need to enter the respective value for Half Length Apparent Magnetic Force & Half Length Coil Current and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!