Normalized Average Output Voltage in Three-Phase Full-Converter Solution

STEP 0: Pre-Calculation Summary
Formula Used
Normalized Output Voltage 3 Phase Full Converter = (cos(Delay Angle of 3 Phase Full Converter))
Vn(3Φ-full) = (cos(αd(3Φ-full)))
This formula uses 1 Functions, 2 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
Variables Used
Normalized Output Voltage 3 Phase Full Converter - Normalized Output Voltage 3 Phase Full Converter is found be normalizing the average output voltage with maximum voltage in a full converter based circuit.
Delay Angle of 3 Phase Full Converter - (Measured in Radian) - Delay Angle of 3 Phase Full Converter refers to the angle at which the thyristor is triggered to start conducting current in a 3 phase AC (alternating current) circuit.
STEP 1: Convert Input(s) to Base Unit
Delay Angle of 3 Phase Full Converter: 70 Degree --> 1.2217304763958 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vn(3Φ-full) = (cos(αd(3Φ-full))) --> (cos(1.2217304763958))
Evaluating ... ...
Vn(3Φ-full) = 0.342020143325886
STEP 3: Convert Result to Output's Unit
0.342020143325886 --> No Conversion Required
FINAL ANSWER
0.342020143325886 0.34202 <-- Normalized Output Voltage 3 Phase Full Converter
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Devyaani Garg
Shiv Nadar University (SNU), Greater Noida
Devyaani Garg has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Three Phase Full Converter Calculators

RMS Output Voltage of Three-Phase Full Converter
​ LaTeX ​ Go RMS Output Voltage 3 Phase Full Converter = ((6)^0.5)*Peak Input Voltage 3 Phase Full Converter*((0.25+0.65*(cos(2*Delay Angle of 3 Phase Full Converter))/pi)^0.5)
Average Output Voltage for Three-Phase Converter
​ LaTeX ​ Go Average Voltage 3 Phase Full Converter = (2*Peak Phase Voltage Full Converter*cos(Delay Angle of 3 Phase Full Converter/2))/pi
Peak Average Output Voltage of Three-Phase Full Converters
​ LaTeX ​ Go Peak Output Voltage 3 Phase Full Converter = (5.2*Peak Input Voltage 3 Phase Full Converter)/pi
Normalized Average Output Voltage in Three-Phase Full-Converter
​ LaTeX ​ Go Normalized Output Voltage 3 Phase Full Converter = (cos(Delay Angle of 3 Phase Full Converter))

Normalized Average Output Voltage in Three-Phase Full-Converter Formula

​LaTeX ​Go
Normalized Output Voltage 3 Phase Full Converter = (cos(Delay Angle of 3 Phase Full Converter))
Vn(3Φ-full) = (cos(αd(3Φ-full)))

What is normalization of voltage?

Normalized quantities are always the ratio of one quantity to other quantity. In the above formula, normalizing the average output voltage with respect to maximum load means finding the ratio of average output voltage to maximum voltage, i.e., Vdc/Vdm.

How to Calculate Normalized Average Output Voltage in Three-Phase Full-Converter?

Normalized Average Output Voltage in Three-Phase Full-Converter calculator uses Normalized Output Voltage 3 Phase Full Converter = (cos(Delay Angle of 3 Phase Full Converter)) to calculate the Normalized Output Voltage 3 Phase Full Converter, The Normalized average output voltage in three-phase full-converter formula is found by normalizing average output voltage to maximum voltage. Normalized Output Voltage 3 Phase Full Converter is denoted by Vn(3Φ-full) symbol.

How to calculate Normalized Average Output Voltage in Three-Phase Full-Converter using this online calculator? To use this online calculator for Normalized Average Output Voltage in Three-Phase Full-Converter, enter Delay Angle of 3 Phase Full Converter d(3Φ-full)) and hit the calculate button. Here is how the Normalized Average Output Voltage in Three-Phase Full-Converter calculation can be explained with given input values -> 0.34202 = (cos(1.2217304763958)).

FAQ

What is Normalized Average Output Voltage in Three-Phase Full-Converter?
The Normalized average output voltage in three-phase full-converter formula is found by normalizing average output voltage to maximum voltage and is represented as Vn(3Φ-full) = (cos(αd(3Φ-full))) or Normalized Output Voltage 3 Phase Full Converter = (cos(Delay Angle of 3 Phase Full Converter)). Delay Angle of 3 Phase Full Converter refers to the angle at which the thyristor is triggered to start conducting current in a 3 phase AC (alternating current) circuit.
How to calculate Normalized Average Output Voltage in Three-Phase Full-Converter?
The Normalized average output voltage in three-phase full-converter formula is found by normalizing average output voltage to maximum voltage is calculated using Normalized Output Voltage 3 Phase Full Converter = (cos(Delay Angle of 3 Phase Full Converter)). To calculate Normalized Average Output Voltage in Three-Phase Full-Converter, you need Delay Angle of 3 Phase Full Converter d(3Φ-full)). With our tool, you need to enter the respective value for Delay Angle of 3 Phase Full Converter and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!