Nominal Strength using Allowable Design Strength Solution

STEP 0: Pre-Calculation Summary
Formula Used
Nominal Strength = Safety Factor for Design Strength*Allowable Design Strength
Rn = fs*Ra
This formula uses 3 Variables
Variables Used
Nominal Strength - (Measured in Pascal) - Nominal Strength is defined as the capacity of the member or structure to resist the effect of loads.
Safety Factor for Design Strength - The Safety Factor for Design Strength expresses how much stronger a system is than it needs to be for an intended load.
Allowable Design Strength - (Measured in Pascal) - Allowable Design Strength is the maximum strength for designing a member.
STEP 1: Convert Input(s) to Base Unit
Safety Factor for Design Strength: 1.8 --> No Conversion Required
Allowable Design Strength: 833.33 Megapascal --> 833330000 Pascal (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Rn = fs*Ra --> 1.8*833330000
Evaluating ... ...
Rn = 1499994000
STEP 3: Convert Result to Output's Unit
1499994000 Pascal -->1499.994 Megapascal (Check conversion ​here)
FINAL ANSWER
1499.994 Megapascal <-- Nominal Strength
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Chandana P Dev
NSS College of Engineering (NSSCE), Palakkad
Chandana P Dev has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Cold Formed or Light Weighted Steel Structures Calculators

Flat Width Ratio of Stiffened Element using Moment of Inertia
​ LaTeX ​ Go Flat Width Ratio = sqrt((Minimum Area Moment of Inertia/(1.83*Thickness of Steel Compression Element^4))^2+144)
Minimum Allowable Moment of Inertia
​ LaTeX ​ Go Minimum Area Moment of Inertia = 1.83*(Thickness of Steel Compression Element^4)*sqrt((Flat Width Ratio^2)-144)
Nominal Strength using Allowable Design Strength
​ LaTeX ​ Go Nominal Strength = Safety Factor for Design Strength*Allowable Design Strength
Allowable Design Strength
​ LaTeX ​ Go Allowable Design Strength = Nominal Strength/Safety Factor for Design Strength

Nominal Strength using Allowable Design Strength Formula

​LaTeX ​Go
Nominal Strength = Safety Factor for Design Strength*Allowable Design Strength
Rn = fs*Ra

What is Nominal Strength?

The Nominal strength is defined as the capacity of a structure or component to resist the effects of loads, as determined by computations using specified material strengths (such as yield strength, Fy, or ultimate. strength, Fu), etc.

How to Calculate Nominal Strength using Allowable Design Strength?

Nominal Strength using Allowable Design Strength calculator uses Nominal Strength = Safety Factor for Design Strength*Allowable Design Strength to calculate the Nominal Strength, The Nominal Strength using Allowable Design Strength can be used to calculate the design strength of a structure as this is the maximum load that is divided by a factor of safety to determine the load that a structure will be designed for. Nominal Strength is denoted by Rn symbol.

How to calculate Nominal Strength using Allowable Design Strength using this online calculator? To use this online calculator for Nominal Strength using Allowable Design Strength, enter Safety Factor for Design Strength (fs) & Allowable Design Strength (Ra) and hit the calculate button. Here is how the Nominal Strength using Allowable Design Strength calculation can be explained with given input values -> 0.0009 = 1.8*833330000.

FAQ

What is Nominal Strength using Allowable Design Strength?
The Nominal Strength using Allowable Design Strength can be used to calculate the design strength of a structure as this is the maximum load that is divided by a factor of safety to determine the load that a structure will be designed for and is represented as Rn = fs*Ra or Nominal Strength = Safety Factor for Design Strength*Allowable Design Strength. The Safety Factor for Design Strength expresses how much stronger a system is than it needs to be for an intended load & Allowable Design Strength is the maximum strength for designing a member.
How to calculate Nominal Strength using Allowable Design Strength?
The Nominal Strength using Allowable Design Strength can be used to calculate the design strength of a structure as this is the maximum load that is divided by a factor of safety to determine the load that a structure will be designed for is calculated using Nominal Strength = Safety Factor for Design Strength*Allowable Design Strength. To calculate Nominal Strength using Allowable Design Strength, you need Safety Factor for Design Strength (fs) & Allowable Design Strength (Ra). With our tool, you need to enter the respective value for Safety Factor for Design Strength & Allowable Design Strength and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!