No Load Speed of Shunt DC Motor Solution

STEP 0: Pre-Calculation Summary
Formula Used
No Load Speed = (Speed Regulation*Full Load Speed)/(100+Full Load Speed)
Nnl = (Nreg*Nfl)/(100+Nfl)
This formula uses 3 Variables
Variables Used
No Load Speed - (Measured in Radian per Second) - No Load Speed is defined as a reference to how fast the shaft of a motor will turn before weight is added to it.
Speed Regulation - (Measured in Radian per Second) - Speed Regulation is the change in speed from no load to full load, expressed as a fraction or percentage of full load speed.
Full Load Speed - (Measured in Radian per Second) - Full Load Speed is defined as the speed of the motor at which the motor is fully loaded to provide its maximum torque to drive the load.
STEP 1: Convert Input(s) to Base Unit
Speed Regulation: 12012 Revolution per Minute --> 1257.8936984333 Radian per Second (Check conversion ​here)
Full Load Speed: 0.19 Revolution per Minute --> 0.0198967534717222 Radian per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Nnl = (Nreg*Nfl)/(100+Nfl) --> (1257.8936984333*0.0198967534717222)/(100+0.0198967534717222)
Evaluating ... ...
Nnl = 0.250230220423533
STEP 3: Convert Result to Output's Unit
0.250230220423533 Radian per Second -->2.38952258960447 Revolution per Minute (Check conversion ​here)
FINAL ANSWER
2.38952258960447 2.389523 Revolution per Minute <-- No Load Speed
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Speed Calculators

Angular Speed of DC Shunt Motor given Kf
​ LaTeX ​ Go Angular Speed = Back EMF/(Constant of Machine Construction*Magnetic Flux)
Speed Regulation of Shunt DC Motor
​ LaTeX ​ Go Speed Regulation = ((No Load Speed-Full Load Speed)/Full Load Speed)*100
No Load Speed of Shunt DC Motor
​ LaTeX ​ Go No Load Speed = (Speed Regulation*Full Load Speed)/(100+Full Load Speed)
Angular Speed of DC Shunt Motor given Output Power
​ LaTeX ​ Go Angular Speed = Output Power/Torque

No Load Speed of Shunt DC Motor Formula

​LaTeX ​Go
No Load Speed = (Speed Regulation*Full Load Speed)/(100+Full Load Speed)
Nnl = (Nreg*Nfl)/(100+Nfl)

Is the speed of DC shunt motor variable?

By varying flux, we can increase the speed more than its base speed. This method is constant power and variable torque drive. Explanation: For a DC shunt motor, speed cannot be varied by the method of starting.

How to Calculate No Load Speed of Shunt DC Motor?

No Load Speed of Shunt DC Motor calculator uses No Load Speed = (Speed Regulation*Full Load Speed)/(100+Full Load Speed) to calculate the No Load Speed, The No Load Speed of Shunt DC Motor formula is defined as a reference to how fast the shaft of a motor will turn before weight is added to it. No Load Speed is denoted by Nnl symbol.

How to calculate No Load Speed of Shunt DC Motor using this online calculator? To use this online calculator for No Load Speed of Shunt DC Motor, enter Speed Regulation (Nreg) & Full Load Speed (Nfl) and hit the calculate button. Here is how the No Load Speed of Shunt DC Motor calculation can be explained with given input values -> 24.72738 = (1257.8936984333*0.0198967534717222)/(100+0.0198967534717222).

FAQ

What is No Load Speed of Shunt DC Motor?
The No Load Speed of Shunt DC Motor formula is defined as a reference to how fast the shaft of a motor will turn before weight is added to it and is represented as Nnl = (Nreg*Nfl)/(100+Nfl) or No Load Speed = (Speed Regulation*Full Load Speed)/(100+Full Load Speed). Speed Regulation is the change in speed from no load to full load, expressed as a fraction or percentage of full load speed & Full Load Speed is defined as the speed of the motor at which the motor is fully loaded to provide its maximum torque to drive the load.
How to calculate No Load Speed of Shunt DC Motor?
The No Load Speed of Shunt DC Motor formula is defined as a reference to how fast the shaft of a motor will turn before weight is added to it is calculated using No Load Speed = (Speed Regulation*Full Load Speed)/(100+Full Load Speed). To calculate No Load Speed of Shunt DC Motor, you need Speed Regulation (Nreg) & Full Load Speed (Nfl). With our tool, you need to enter the respective value for Speed Regulation & Full Load Speed and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!