Negative Moment at Exterior Face of First Interior Support for Two Spans Solution

STEP 0: Pre-Calculation Summary
Formula Used
Moment in Structures = (Vertical Load*Length of Span^2)/9
Mt = (Wload*In^2)/9
This formula uses 3 Variables
Variables Used
Moment in Structures - (Measured in Joule) - The Moment in Structures is an overturning effect (tends to bend or turn the member) created by the force(load) acting on a structural member.
Vertical Load - (Measured in Kilonewton) - Vertical Load are applied perpendicular to the surface.
Length of Span - (Measured in Meter) - Length of Span refers to the length of the opening above which the beam is spanning.
STEP 1: Convert Input(s) to Base Unit
Vertical Load: 3.6 Kilonewton --> 3.6 Kilonewton No Conversion Required
Length of Span: 10.01 Meter --> 10.01 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Mt = (Wload*In^2)/9 --> (3.6*10.01^2)/9
Evaluating ... ...
Mt = 40.08004
STEP 3: Convert Result to Output's Unit
40.08004 Joule -->40.08004 Newton Meter (Check conversion ​here)
FINAL ANSWER
40.08004 Newton Meter <-- Moment in Structures
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has created this Calculator and 1000+ more calculators!
Verifier Image
Verified by Rudrani Tidke
Cummins College of Engineering for Women (CCEW), Pune
Rudrani Tidke has verified this Calculator and 50+ more calculators!

Use of Moment Coefficients Calculators

Positive Moment for End Spans if Discontinuous End is Integral with Support
​ LaTeX ​ Go Moment in Structures = (Vertical Load*Length of Span^2)/14
Positive Moment for End Spans if Discontinuous End is Unrestrained
​ LaTeX ​ Go Moment in Structures = (Vertical Load*Length of Span^2)/11
Positive Moment for Interior Spans
​ LaTeX ​ Go Moment in Structures = (Vertical Load*Length of Span^2)/16
Negative Moment at Exterior Face of First Interior Support for Two Spans
​ LaTeX ​ Go Moment in Structures = (Vertical Load*Length of Span^2)/9

Negative Moment at Exterior Face of First Interior Support for Two Spans Formula

​LaTeX ​Go
Moment in Structures = (Vertical Load*Length of Span^2)/9
Mt = (Wload*In^2)/9

Define Moment

The Moment of a force is a measure of its tendency to cause a body to rotate about a specific point or axis. This is different from the tendency for a body to move, or translate, in the direction of the force.

How to Calculate Negative Moment at Exterior Face of First Interior Support for Two Spans?

Negative Moment at Exterior Face of First Interior Support for Two Spans calculator uses Moment in Structures = (Vertical Load*Length of Span^2)/9 to calculate the Moment in Structures, The Negative Moment at Exterior Face of First Interior Support for Two Spans is defined as the beam is forced to curve up (forming a frown) above supports. Moment in Structures is denoted by Mt symbol.

How to calculate Negative Moment at Exterior Face of First Interior Support for Two Spans using this online calculator? To use this online calculator for Negative Moment at Exterior Face of First Interior Support for Two Spans, enter Vertical Load (Wload) & Length of Span (In) and hit the calculate button. Here is how the Negative Moment at Exterior Face of First Interior Support for Two Spans calculation can be explained with given input values -> 0.04 = (3600*0.01001^2)/9.

FAQ

What is Negative Moment at Exterior Face of First Interior Support for Two Spans?
The Negative Moment at Exterior Face of First Interior Support for Two Spans is defined as the beam is forced to curve up (forming a frown) above supports and is represented as Mt = (Wload*In^2)/9 or Moment in Structures = (Vertical Load*Length of Span^2)/9. Vertical Load are applied perpendicular to the surface & Length of Span refers to the length of the opening above which the beam is spanning.
How to calculate Negative Moment at Exterior Face of First Interior Support for Two Spans?
The Negative Moment at Exterior Face of First Interior Support for Two Spans is defined as the beam is forced to curve up (forming a frown) above supports is calculated using Moment in Structures = (Vertical Load*Length of Span^2)/9. To calculate Negative Moment at Exterior Face of First Interior Support for Two Spans, you need Vertical Load (Wload) & Length of Span (In). With our tool, you need to enter the respective value for Vertical Load & Length of Span and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Moment in Structures?
In this formula, Moment in Structures uses Vertical Load & Length of Span. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Moment in Structures = (Vertical Load*Length of Span^2)/11
  • Moment in Structures = (Vertical Load*Length of Span^2)/14
  • Moment in Structures = (Vertical Load*Length of Span^2)/16
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!