Modified Heat Transfer Coefficient under Influence of Pressure Solution

STEP 0: Pre-Calculation Summary
Formula Used
Heat Transfer Coefficient at Some Pressure P = (Heat Transfer Coefficient at Atmospheric Pressure)*((System Pressure/Standard Atmospheric Pressure)^(0.4))
hp = (h1)*((ps/p1)^(0.4))
This formula uses 4 Variables
Variables Used
Heat Transfer Coefficient at Some Pressure P - (Measured in Watt per Square Meter per Kelvin) - Heat Transfer Coefficient at Some Pressure P is the heat transferred per unit area per kelvin.
Heat Transfer Coefficient at Atmospheric Pressure - (Measured in Watt per Square Meter per Kelvin) - Heat Transfer Coefficient at Atmospheric Pressure is the heat transferred per unit area per kelvin.
System Pressure - (Measured in Pascal) - System Pressure is the pressure that is being exerted on the system.
Standard Atmospheric Pressure - (Measured in Pascal) - Standard Atmospheric Pressure is the pressure that is being exerted on the system by the atmosphere.
STEP 1: Convert Input(s) to Base Unit
Heat Transfer Coefficient at Atmospheric Pressure: 10.9 Watt per Square Meter per Kelvin --> 10.9 Watt per Square Meter per Kelvin No Conversion Required
System Pressure: 3.5 Pascal --> 3.5 Pascal No Conversion Required
Standard Atmospheric Pressure: 0.101325 Pascal --> 0.101325 Pascal No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
hp = (h1)*((ps/p1)^(0.4)) --> (10.9)*((3.5/0.101325)^(0.4))
Evaluating ... ...
hp = 44.9538684871627
STEP 3: Convert Result to Output's Unit
44.9538684871627 Watt per Square Meter per Kelvin --> No Conversion Required
FINAL ANSWER
44.9538684871627 44.95387 Watt per Square Meter per Kelvin <-- Heat Transfer Coefficient at Some Pressure P
(Calculation completed in 00.006 seconds)

Credits

Creator Image
Created by Ayush gupta
University School of Chemical Technology-USCT (GGSIPU), New Delhi
Ayush gupta has created this Calculator and 300+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

Boiling Calculators

Critical Heat Flux by Zuber
​ LaTeX ​ Go Critical Heat Flux = ((0.149*Enthalpy of Vaporization of Liquid*Density of Vapor)*(((Surface Tension*[g])*(Density of Liquid-Density of Vapor))/(Density of Vapor^2))^(1/4))
Correlation for Heat Flux proposed by Mostinski
​ LaTeX ​ Go Heat Transfer Coefficient For Nucleate Boiling = 0.00341*(Critical Pressure^2.3)*(Excess Temperature in Nucleate Boiling^2.33)*(Reduced Pressure^0.566)
Heat Transfer Coefficient for Forced Convection Local Boiling Inside Vertical Tubes
​ LaTeX ​ Go Heat Transfer Coefficient for Forced Convection = (2.54*((Excess Temperature)^3)*exp((System Pressure in Vertical Tubes)/1.551))
Excess Temperature in Boiling
​ LaTeX ​ Go Excess Temperature in Heat Transfer = Surface Temperature-Saturation Temperature

Modified Heat Transfer Coefficient under Influence of Pressure Formula

​LaTeX ​Go
Heat Transfer Coefficient at Some Pressure P = (Heat Transfer Coefficient at Atmospheric Pressure)*((System Pressure/Standard Atmospheric Pressure)^(0.4))
hp = (h1)*((ps/p1)^(0.4))

What is Heat Transfer?

Heat transfer is a discipline of thermal engineering that concerns the generation, use, conversion, and exchange of thermal energy between physical systems. Heat transfer is classified into various mechanisms, such as thermal conduction, thermal convection, thermal radiation, and transfer of energy by phase changes.

Define Thermal Conductivity & Factors affecting it?

Thermal conductivity is defined as the ability of a substance to conduct heat. Factors Affecting The Thermal Conductivity are: Moisture, Density of material, Pressure, Temperature & Structure of material.

How to Calculate Modified Heat Transfer Coefficient under Influence of Pressure?

Modified Heat Transfer Coefficient under Influence of Pressure calculator uses Heat Transfer Coefficient at Some Pressure P = (Heat Transfer Coefficient at Atmospheric Pressure)*((System Pressure/Standard Atmospheric Pressure)^(0.4)) to calculate the Heat Transfer Coefficient at Some Pressure P, The Modified Heat Transfer Coefficient under Influence of Pressure formula is a function of Heat Transfer Coefficient at Atmospheric Pressure, System Pressure & Standard Atmospheric Pressure. The modified heat transfer coefficient is affected by a number of factors, including the fluid flow velocity, the fluid properties, the surface roughness, and the presence of any fouling. In general, the modified heat transfer coefficient increases with increasing fluid flow velocity and decreasing surface roughness. Heat Transfer Coefficient at Some Pressure P is denoted by hp symbol.

How to calculate Modified Heat Transfer Coefficient under Influence of Pressure using this online calculator? To use this online calculator for Modified Heat Transfer Coefficient under Influence of Pressure, enter Heat Transfer Coefficient at Atmospheric Pressure (h1), System Pressure (ps) & Standard Atmospheric Pressure (p1) and hit the calculate button. Here is how the Modified Heat Transfer Coefficient under Influence of Pressure calculation can be explained with given input values -> 44.95387 = (10.9)*((3.5/0.101325)^(0.4)).

FAQ

What is Modified Heat Transfer Coefficient under Influence of Pressure?
The Modified Heat Transfer Coefficient under Influence of Pressure formula is a function of Heat Transfer Coefficient at Atmospheric Pressure, System Pressure & Standard Atmospheric Pressure. The modified heat transfer coefficient is affected by a number of factors, including the fluid flow velocity, the fluid properties, the surface roughness, and the presence of any fouling. In general, the modified heat transfer coefficient increases with increasing fluid flow velocity and decreasing surface roughness and is represented as hp = (h1)*((ps/p1)^(0.4)) or Heat Transfer Coefficient at Some Pressure P = (Heat Transfer Coefficient at Atmospheric Pressure)*((System Pressure/Standard Atmospheric Pressure)^(0.4)). Heat Transfer Coefficient at Atmospheric Pressure is the heat transferred per unit area per kelvin, System Pressure is the pressure that is being exerted on the system & Standard Atmospheric Pressure is the pressure that is being exerted on the system by the atmosphere.
How to calculate Modified Heat Transfer Coefficient under Influence of Pressure?
The Modified Heat Transfer Coefficient under Influence of Pressure formula is a function of Heat Transfer Coefficient at Atmospheric Pressure, System Pressure & Standard Atmospheric Pressure. The modified heat transfer coefficient is affected by a number of factors, including the fluid flow velocity, the fluid properties, the surface roughness, and the presence of any fouling. In general, the modified heat transfer coefficient increases with increasing fluid flow velocity and decreasing surface roughness is calculated using Heat Transfer Coefficient at Some Pressure P = (Heat Transfer Coefficient at Atmospheric Pressure)*((System Pressure/Standard Atmospheric Pressure)^(0.4)). To calculate Modified Heat Transfer Coefficient under Influence of Pressure, you need Heat Transfer Coefficient at Atmospheric Pressure (h1), System Pressure (ps) & Standard Atmospheric Pressure (p1). With our tool, you need to enter the respective value for Heat Transfer Coefficient at Atmospheric Pressure, System Pressure & Standard Atmospheric Pressure and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!