Membrane Flux Based on Resistance Solution

STEP 0: Pre-Calculation Summary
Formula Used
Flux through Membrane = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity)
JwM = ΔPm/(Rm*μ)
This formula uses 4 Variables
Variables Used
Flux through Membrane - (Measured in Cubic Meter per Square Meter per Second) - Flux through membrane is defined as the rate of movement or transfer of a substance per unit area across a porous barrier known as a membrane.
Applied Pressure Driving Force - (Measured in Pascal) - Applied Pressure Driving Force is defined as the force or pressure that is intentionally exerted or applied to induce or facilitate process.
Membrane Flow Resistance of Unit Area - (Measured in 1 per Meter) - Membrane flow resistance of unit area is defined as the measure of the resistance that a membrane presents to the flow of a substance through it, normalized by the area of the membrane.
Liquid Viscosity - (Measured in Pascal Second) - Liquid viscosity is defined as the measure of a fluid's resistance to flow or its internal friction when subjected to an external force.
STEP 1: Convert Input(s) to Base Unit
Applied Pressure Driving Force: 300000 Pascal --> 300000 Pascal No Conversion Required
Membrane Flow Resistance of Unit Area: 48003072200 1 per Meter --> 48003072200 1 per Meter No Conversion Required
Liquid Viscosity: 0.0009 Kilogram per Meter per Second --> 0.0009 Pascal Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
JwM = ΔPm/(Rm*μ) --> 300000/(48003072200*0.0009)
Evaluating ... ...
JwM = 0.00694399999951114
STEP 3: Convert Result to Output's Unit
0.00694399999951114 Cubic Meter per Square Meter per Second --> No Conversion Required
FINAL ANSWER
0.00694399999951114 0.006944 Cubic Meter per Square Meter per Second <-- Flux through Membrane
(Calculation completed in 00.008 seconds)

Credits

Creator Image
Created by Harsh Kadam
Shri Guru Gobind Singhji Institute of Engineering and Technology (SGGS), Nanded
Harsh Kadam has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has verified this Calculator and 200+ more calculators!

Basics of Membrane Separation Processes Calculators

Hagen Poiseuille Based Flux for Membrane Separation
​ LaTeX ​ Go Flux through Membrane = (Membrane Porosity*Pore Diameter^2*Applied Pressure Driving Force)/(32*Liquid Viscosity*Tortuosity*Membrane Thickness)
Liquid Viscosity based on Membrane Resistance
​ LaTeX ​ Go Liquid Viscosity = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Flux through Membrane)
Membrane Flux Based on Resistance
​ LaTeX ​ Go Flux through Membrane = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity)
Resistance to flow in Membranes
​ LaTeX ​ Go Membrane Flow Resistance of Unit Area = Applied Pressure Driving Force/(Liquid Viscosity*Flux through Membrane)

Membrane Flux Based on Resistance Formula

​LaTeX ​Go
Flux through Membrane = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity)
JwM = ΔPm/(Rm*μ)

What is Membrane Flux?

"Membrane flux" refers to the rate of movement of substances, such as liquids or particles, across a membrane per unit area. It quantifies how quickly materials pass through a membrane and is influenced by factors like concentration gradients, membrane properties, and applied pressure.

How to Calculate Membrane Flux Based on Resistance?

Membrane Flux Based on Resistance calculator uses Flux through Membrane = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity) to calculate the Flux through Membrane, The Membrane Flux Based on Resistance formula is defined as is the rate of substance flow through a membrane, determined by the resistance the substance encounters while crossing the membrane. Flux through Membrane is denoted by JwM symbol.

How to calculate Membrane Flux Based on Resistance using this online calculator? To use this online calculator for Membrane Flux Based on Resistance, enter Applied Pressure Driving Force (ΔPm), Membrane Flow Resistance of Unit Area (Rm) & Liquid Viscosity (μ) and hit the calculate button. Here is how the Membrane Flux Based on Resistance calculation can be explained with given input values -> 0.017361 = 300000/(48003072200*0.0009).

FAQ

What is Membrane Flux Based on Resistance?
The Membrane Flux Based on Resistance formula is defined as is the rate of substance flow through a membrane, determined by the resistance the substance encounters while crossing the membrane and is represented as JwM = ΔPm/(Rm*μ) or Flux through Membrane = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity). Applied Pressure Driving Force is defined as the force or pressure that is intentionally exerted or applied to induce or facilitate process, Membrane flow resistance of unit area is defined as the measure of the resistance that a membrane presents to the flow of a substance through it, normalized by the area of the membrane & Liquid viscosity is defined as the measure of a fluid's resistance to flow or its internal friction when subjected to an external force.
How to calculate Membrane Flux Based on Resistance?
The Membrane Flux Based on Resistance formula is defined as is the rate of substance flow through a membrane, determined by the resistance the substance encounters while crossing the membrane is calculated using Flux through Membrane = Applied Pressure Driving Force/(Membrane Flow Resistance of Unit Area*Liquid Viscosity). To calculate Membrane Flux Based on Resistance, you need Applied Pressure Driving Force (ΔPm), Membrane Flow Resistance of Unit Area (Rm) & Liquid Viscosity (μ). With our tool, you need to enter the respective value for Applied Pressure Driving Force, Membrane Flow Resistance of Unit Area & Liquid Viscosity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Flux through Membrane?
In this formula, Flux through Membrane uses Applied Pressure Driving Force, Membrane Flow Resistance of Unit Area & Liquid Viscosity. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Flux through Membrane = (Membrane Porosity*Pore Diameter^2*Applied Pressure Driving Force)/(32*Liquid Viscosity*Tortuosity*Membrane Thickness)
  • Flux through Membrane = Water Permeability Through Membrane*Applied Pressure
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!