Mean Temperature in Entire Catchment given Run-off in cm Solution

STEP 0: Pre-Calculation Summary
Formula Used
Temperature = ((Rainfall Depth-Runoff Depth in CM for Khosla's Formula)*3.74)+32
Tf = ((Pcm-RKC)*3.74)+32
This formula uses 3 Variables
Variables Used
Temperature - (Measured in Fahrenheit) - Temperature is the degree or intensity of heat present in a substance or object.
Rainfall Depth - (Measured in Centimeter) - Rainfall Depth refers to the vertical height of rainwater accumulated over a surface during a specific period, typically measured in millimeters (mm) or inches.
Runoff Depth in CM for Khosla's Formula - (Measured in Centimeter) - Runoff Depth in CM for Khosla's Formula refers to the portion of precipitation or irrigation that flows over the land surface into streams, rivers, or other water bodies.
STEP 1: Convert Input(s) to Base Unit
Rainfall Depth: 12 Centimeter --> 12 Centimeter No Conversion Required
Runoff Depth in CM for Khosla's Formula: 10.39 Centimeter --> 10.39 Centimeter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Tf = ((Pcm-RKC)*3.74)+32 --> ((12-10.39)*3.74)+32
Evaluating ... ...
Tf = 38.0214
STEP 3: Convert Result to Output's Unit
276.495216278219 Kelvin -->38.0214001276101 Fahrenheit (Check conversion ​here)
FINAL ANSWER
38.0214001276101 38.0214 Fahrenheit <-- Temperature
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Khosla's Formula Calculators

Mean Temperature in Entire Catchment given Run-off
​ LaTeX ​ Go Temperature = ((Rainfall Depth in Inches-Runoff Depth in Inches for Khosla's Formula)*9.5)+32
Rainfall in Inches by Khosla's Formula
​ LaTeX ​ Go Rainfall Depth in Inches = Runoff Depth in Inches for Khosla's Formula+((Temperature-32)/9.5)
Run-off in Inches by Khosla's Formula
​ LaTeX ​ Go Runoff Depth in Inches for Khosla's Formula = Rainfall Depth in Inches-((Temperature-32)/9.5)
Run-off in cm by Khosla's Formula
​ LaTeX ​ Go Runoff Depth in CM for Khosla's Formula = Rainfall Depth-((Temperature-32)/3.74)

Mean Temperature in Entire Catchment given Run-off in cm Formula

​LaTeX ​Go
Temperature = ((Rainfall Depth-Runoff Depth in CM for Khosla's Formula)*3.74)+32
Tf = ((Pcm-RKC)*3.74)+32

What is Catchment Area ?

A catchment is an area of land where water collects when it rains, often bounded by hills. As the water flows over the landscape it finds its way into streams and down into the soil, eventually feeding the river.

How to Calculate Mean Temperature in Entire Catchment given Run-off in cm?

Mean Temperature in Entire Catchment given Run-off in cm calculator uses Temperature = ((Rainfall Depth-Runoff Depth in CM for Khosla's Formula)*3.74)+32 to calculate the Temperature, The Mean Temperature in Entire Catchment given Run-off in cm is defined as the degree or intensity of heat present in a substance or object. Temperature is denoted by Tf symbol.

How to calculate Mean Temperature in Entire Catchment given Run-off in cm using this online calculator? To use this online calculator for Mean Temperature in Entire Catchment given Run-off in cm, enter Rainfall Depth (Pcm) & Runoff Depth in CM for Khosla's Formula (RKC) and hit the calculate button. Here is how the Mean Temperature in Entire Catchment given Run-off in cm calculation can be explained with given input values -> -1163.886581 = ((0.12-0.1039)*3.74)+32.

FAQ

What is Mean Temperature in Entire Catchment given Run-off in cm?
The Mean Temperature in Entire Catchment given Run-off in cm is defined as the degree or intensity of heat present in a substance or object and is represented as Tf = ((Pcm-RKC)*3.74)+32 or Temperature = ((Rainfall Depth-Runoff Depth in CM for Khosla's Formula)*3.74)+32. Rainfall Depth refers to the vertical height of rainwater accumulated over a surface during a specific period, typically measured in millimeters (mm) or inches & Runoff Depth in CM for Khosla's Formula refers to the portion of precipitation or irrigation that flows over the land surface into streams, rivers, or other water bodies.
How to calculate Mean Temperature in Entire Catchment given Run-off in cm?
The Mean Temperature in Entire Catchment given Run-off in cm is defined as the degree or intensity of heat present in a substance or object is calculated using Temperature = ((Rainfall Depth-Runoff Depth in CM for Khosla's Formula)*3.74)+32. To calculate Mean Temperature in Entire Catchment given Run-off in cm, you need Rainfall Depth (Pcm) & Runoff Depth in CM for Khosla's Formula (RKC). With our tool, you need to enter the respective value for Rainfall Depth & Runoff Depth in CM for Khosla's Formula and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Temperature?
In this formula, Temperature uses Rainfall Depth & Runoff Depth in CM for Khosla's Formula. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Temperature = ((Rainfall Depth in Inches-Runoff Depth in Inches for Khosla's Formula)*9.5)+32
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!