Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube Solution

STEP 0: Pre-Calculation Summary
Formula Used
Surface Area = (Heat Transfer*Tube Thickness)/(Thermal Conductivity*(Outside Surface Temperature-Inside Surface temperature))
SA = (q*x)/(k*(T2-T3))
This formula uses 6 Variables
Variables Used
Surface Area - (Measured in Square Meter) - The Surface Area of a three-dimensional shape is the sum of all of the surface areas of each of the sides.
Heat Transfer - (Measured in Watt) - Heat Transfer is the amount of heat that is transferred per unit of time in some material, usually measured in watts (joules per second).
Tube Thickness - (Measured in Meter) - Tube Thickness is the thickness of the tube defined by a gauge number.
Thermal Conductivity - (Measured in Watt per Meter per K) - Thermal Conductivity is rate of heat passes through specified material, expressed as amount of heat flows per unit time through a unit area with a temperature gradient of one degree per unit distance.
Outside Surface Temperature - (Measured in Kelvin) - Outside Surface Temperature is the Temperature at the outside surface of the tube.
Inside Surface temperature - (Measured in Kelvin) - Inside Surface Temperature is the temperature at the inside surface of the tube.
STEP 1: Convert Input(s) to Base Unit
Heat Transfer: 7.54 Watt --> 7.54 Watt No Conversion Required
Tube Thickness: 11233 Millimeter --> 11.233 Meter (Check conversion ​here)
Thermal Conductivity: 10.18 Watt per Meter per K --> 10.18 Watt per Meter per K No Conversion Required
Outside Surface Temperature: 310 Kelvin --> 310 Kelvin No Conversion Required
Inside Surface temperature: 302 Kelvin --> 302 Kelvin No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
SA = (q*x)/(k*(T2-T3)) --> (7.54*11.233)/(10.18*(310-302))
Evaluating ... ...
SA = 1.03999042239686
STEP 3: Convert Result to Output's Unit
1.03999042239686 Square Meter --> No Conversion Required
FINAL ANSWER
1.03999042239686 1.03999 Square Meter <-- Surface Area
(Calculation completed in 00.007 seconds)

Credits

Creator Image
Vishwakarma Institute of Information Technology, Pune (VIIT Pune), Pune
Abhishek Dharmendra Bansile has created this Calculator and 100+ more calculators!
Verifier Image
Verified by sanjay shiva
national institute of technology hamirpur (NITH ), hamirpur , himachal pradesh
sanjay shiva has verified this Calculator and 100+ more calculators!

Heat Transfer Calculators

Heat Rejection Factor
​ LaTeX ​ Go Heat Rejection Factor = (Refrigeration Capacity+Compressor Work Done)/Refrigeration Capacity
Refrigeration Capacity given Load on Condenser
​ LaTeX ​ Go Refrigeration Capacity = Load on Condenser-Compressor Work Done
Load on Condenser
​ LaTeX ​ Go Load on Condenser = Refrigeration Capacity+Compressor Work Done
Heat Rejection Factor given COP
​ LaTeX ​ Go Heat Rejection Factor = 1+(1/Coefficient of Performance of Refrigerator)

Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube Formula

​LaTeX ​Go
Surface Area = (Heat Transfer*Tube Thickness)/(Thermal Conductivity*(Outside Surface Temperature-Inside Surface temperature))
SA = (q*x)/(k*(T2-T3))

Natural convection air-cooled condensers

In natural convection air-cooled condenser, the heat transfer from the condenser coils to the air is by natural convection. As the air comes in contact with the warm condenser tubes, it absorbs heat from the refrigerant, and thus the temperature of the air increases. The warm air, being lighter, rises up and the cold air from below rises to take away the heat from the condenser.

Forced convection air-cooled condensers

In forced convection air-cooled condensers, the fan (either propeller or centrifugal) is used to force the air over the condenser coils to increase its heat transfer capacity. The forced convection condensers may be divided into the following two groups: (a) Base mounted air-cooled condensers, and (b) Remote air-cooled condensers.

How to Calculate Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube?

Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube calculator uses Surface Area = (Heat Transfer*Tube Thickness)/(Thermal Conductivity*(Outside Surface Temperature-Inside Surface temperature)) to calculate the Surface Area, Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube formula is defined as the total area of the tube where heat transfer occurs from the outer surface to the inner surface, playing a crucial role in heat exchanger design and performance analysis. Surface Area is denoted by SA symbol.

How to calculate Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube using this online calculator? To use this online calculator for Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube, enter Heat Transfer (q), Tube Thickness (x), Thermal Conductivity (k), Outside Surface Temperature (T2) & Inside Surface temperature (T3) and hit the calculate button. Here is how the Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube calculation can be explained with given input values -> 0.060179 = (7.54*11.233)/(10.18*(310-302)).

FAQ

What is Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube?
Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube formula is defined as the total area of the tube where heat transfer occurs from the outer surface to the inner surface, playing a crucial role in heat exchanger design and performance analysis and is represented as SA = (q*x)/(k*(T2-T3)) or Surface Area = (Heat Transfer*Tube Thickness)/(Thermal Conductivity*(Outside Surface Temperature-Inside Surface temperature)). Heat Transfer is the amount of heat that is transferred per unit of time in some material, usually measured in watts (joules per second), Tube Thickness is the thickness of the tube defined by a gauge number, Thermal Conductivity is rate of heat passes through specified material, expressed as amount of heat flows per unit time through a unit area with a temperature gradient of one degree per unit distance, Outside Surface Temperature is the Temperature at the outside surface of the tube & Inside Surface Temperature is the temperature at the inside surface of the tube.
How to calculate Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube?
Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube formula is defined as the total area of the tube where heat transfer occurs from the outer surface to the inner surface, playing a crucial role in heat exchanger design and performance analysis is calculated using Surface Area = (Heat Transfer*Tube Thickness)/(Thermal Conductivity*(Outside Surface Temperature-Inside Surface temperature)). To calculate Mean Surface area of Tube when Heat transfer takes place from outside to inside surface of tube, you need Heat Transfer (q), Tube Thickness (x), Thermal Conductivity (k), Outside Surface Temperature (T2) & Inside Surface temperature (T3). With our tool, you need to enter the respective value for Heat Transfer, Tube Thickness, Thermal Conductivity, Outside Surface Temperature & Inside Surface temperature and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!