Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximum Voltage = sqrt(6*Resistivity*(Power Transmitted*Length of Wire DC)^2/(Line Losses*Volume Of Conductor*(cos(Theta))^2))
Vm = sqrt(6*ρ*(P*l)^2/(Pline*V*(cos(θ))^2))
This formula uses 2 Functions, 7 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Maximum Voltage - (Measured in Volt) - Maximum Voltage the highest voltage rating for electrical devices.
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Power Transmitted - (Measured in Watt) - Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Length of Wire DC - (Measured in Meter) - Length of Wire DC is the measurement or extent of something from end to end.
Line Losses - (Measured in Watt) - Line Losses is defined as the losses that are produced in the line.
Volume Of Conductor - (Measured in Cubic Meter) - Volume Of Conductor the 3-dimensional space enclosed by a conductor material.
Theta - (Measured in Radian) - Theta is an angle that can be defined as the figure formed by two rays meeting at a common endpoint.
STEP 1: Convert Input(s) to Base Unit
Resistivity: 1.7E-05 Ohm Meter --> 1.7E-05 Ohm Meter No Conversion Required
Power Transmitted: 300 Watt --> 300 Watt No Conversion Required
Length of Wire DC: 3.2 Meter --> 3.2 Meter No Conversion Required
Line Losses: 0.6 Watt --> 0.6 Watt No Conversion Required
Volume Of Conductor: 35 Cubic Meter --> 35 Cubic Meter No Conversion Required
Theta: 30 Degree --> 0.5235987755982 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vm = sqrt(6*ρ*(P*l)^2/(Pline*V*(cos(θ))^2)) --> sqrt(6*1.7E-05*(300*3.2)^2/(0.6*35*(cos(0.5235987755982))^2))
Evaluating ... ...
Vm = 2.44304259947655
STEP 3: Convert Result to Output's Unit
2.44304259947655 Volt --> No Conversion Required
FINAL ANSWER
2.44304259947655 2.443043 Volt <-- Maximum Voltage
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Current and Voltage Calculators

Maximum Voltage using Area of X-Section (DC Three-Wire US)
​ LaTeX ​ Go Maximum Voltage = sqrt(2*(Power Transmitted^2)*Resistivity*Length of Wire DC/(Line Losses*Area of underground dc wire))
Maximum Voltage using Volume of Conductor Material(DC Three-Wire US)
​ LaTeX ​ Go Maximum Voltage = sqrt(5*Resistivity*(Power Transmitted*Length of Wire DC)^2/(Line Losses*Volume Of Conductor))
Maximum Voltage using Line Losses (DC Three-Wire US)
​ LaTeX ​ Go Maximum Voltage = sqrt(2*(Power Transmitted^2)*Resistance underground DC/(Line Losses))
Load Current using Line Losses (DC Three-Wire US)
​ LaTeX ​ Go Current underground DC = sqrt(Line Losses/(2*Resistance underground DC))

Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US) Formula

​LaTeX ​Go
Maximum Voltage = sqrt(6*Resistivity*(Power Transmitted*Length of Wire DC)^2/(Line Losses*Volume Of Conductor*(cos(Theta))^2))
Vm = sqrt(6*ρ*(P*l)^2/(Pline*V*(cos(θ))^2))

What is the value of maximum voltage and volume of conductor material in 3-phase 3-wire system?

The volume of conductor material required in this system is 1.5/cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is vm/√3 so that r.m.s. value of voltage between them is vm/√6.

How to Calculate Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US)?

Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US) calculator uses Maximum Voltage = sqrt(6*Resistivity*(Power Transmitted*Length of Wire DC)^2/(Line Losses*Volume Of Conductor*(cos(Theta))^2)) to calculate the Maximum Voltage, The Maximum Voltage using Volume of Conductor Material (3-phase 3-wire US) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition. Maximum Voltage is denoted by Vm symbol.

How to calculate Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US) using this online calculator? To use this online calculator for Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US), enter Resistivity (ρ), Power Transmitted (P), Length of Wire DC (l), Line Losses (Pline), Volume Of Conductor (V) & Theta (θ) and hit the calculate button. Here is how the Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US) calculation can be explained with given input values -> 2.443043 = sqrt(6*1.7E-05*(300*3.2)^2/(0.6*35*(cos(0.5235987755982))^2)).

FAQ

What is Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US)?
The Maximum Voltage using Volume of Conductor Material (3-phase 3-wire US) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition and is represented as Vm = sqrt(6*ρ*(P*l)^2/(Pline*V*(cos(θ))^2)) or Maximum Voltage = sqrt(6*Resistivity*(Power Transmitted*Length of Wire DC)^2/(Line Losses*Volume Of Conductor*(cos(Theta))^2)). Resistivity is the measure of how strongly a material opposes the flow of current through them, Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work, Length of Wire DC is the measurement or extent of something from end to end, Line Losses is defined as the losses that are produced in the line, Volume Of Conductor the 3-dimensional space enclosed by a conductor material & Theta is an angle that can be defined as the figure formed by two rays meeting at a common endpoint.
How to calculate Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US)?
The Maximum Voltage using Volume of Conductor Material (3-phase 3-wire US) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition is calculated using Maximum Voltage = sqrt(6*Resistivity*(Power Transmitted*Length of Wire DC)^2/(Line Losses*Volume Of Conductor*(cos(Theta))^2)). To calculate Maximum Voltage using Volume of Conductor Material (3-Phase 3-Wire US), you need Resistivity (ρ), Power Transmitted (P), Length of Wire DC (l), Line Losses (Pline), Volume Of Conductor (V) & Theta (θ). With our tool, you need to enter the respective value for Resistivity, Power Transmitted, Length of Wire DC, Line Losses, Volume Of Conductor & Theta and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Maximum Voltage?
In this formula, Maximum Voltage uses Resistivity, Power Transmitted, Length of Wire DC, Line Losses, Volume Of Conductor & Theta. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Maximum Voltage = sqrt(5*Resistivity*(Power Transmitted*Length of Wire DC)^2/(Line Losses*Volume Of Conductor))
  • Maximum Voltage = sqrt(2*(Power Transmitted^2)*Resistivity*Length of Wire DC/(Line Losses*Area of underground dc wire))
  • Maximum Voltage = sqrt(2*(Power Transmitted^2)*Resistance underground DC/(Line Losses))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!