Maximum Voltage using Load Current (2 Phase 4 Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximum Voltage Underground AC = sqrt(2)*Power Transmitted/(Current Underground AC*cos(Phase Difference))
Vm = sqrt(2)*P/(I*cos(Φ))
This formula uses 2 Functions, 4 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Maximum Voltage Underground AC - (Measured in Volt) - Maximum Voltage Underground AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Power Transmitted - (Measured in Watt) - Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Current Underground AC - (Measured in Ampere) - Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Phase Difference - (Measured in Radian) - Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
STEP 1: Convert Input(s) to Base Unit
Power Transmitted: 300 Watt --> 300 Watt No Conversion Required
Current Underground AC: 9 Ampere --> 9 Ampere No Conversion Required
Phase Difference: 30 Degree --> 0.5235987755982 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vm = sqrt(2)*P/(I*cos(Φ)) --> sqrt(2)*300/(9*cos(0.5235987755982))
Evaluating ... ...
Vm = 54.4331053951817
STEP 3: Convert Result to Output's Unit
54.4331053951817 Volt --> No Conversion Required
FINAL ANSWER
54.4331053951817 54.43311 Volt <-- Maximum Voltage Underground AC
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Current and Voltage Calculators

Maximum Voltage using Area of X-Section (2 Phase 4 Wire US)
​ LaTeX ​ Go Maximum Voltage Underground AC = (2*Power Transmitted/cos(Phase Difference))*sqrt(Resistivity*Length of Underground AC Wire/(Line Losses*Area of Underground AC Wire))
RMS Voltage using Area of X-Section (2 Phase 4 Wire US)
​ LaTeX ​ Go Root Mean Square Voltage = (Power Transmitted/cos(Phase Difference))*sqrt(Resistivity*Length of Underground AC Wire/(Line Losses*Area of Underground AC Wire))
Load Current using Area of X-Section (2 Phase 4 Wire US)
​ LaTeX ​ Go Current Underground AC = sqrt(Line Losses*Area of Underground AC Wire/(2*Resistivity*Length of Underground AC Wire))
Load Current using Line Losses (2 Phase 4 Wire US)
​ LaTeX ​ Go Current Underground AC = sqrt(Line Losses/2*Resistance Underground AC)

Maximum Voltage using Load Current (2 Phase 4 Wire US) Formula

​LaTeX ​Go
Maximum Voltage Underground AC = sqrt(2)*Power Transmitted/(Current Underground AC*cos(Phase Difference))
Vm = sqrt(2)*P/(I*cos(Φ))

What is the value of maximum voltage in 2-phase 4-wire underground system?

The maximum voltage between conductors is vm so that r.m.s. value of voltage between them is vm/√2.

How to Calculate Maximum Voltage using Load Current (2 Phase 4 Wire US)?

Maximum Voltage using Load Current (2 Phase 4 Wire US) calculator uses Maximum Voltage Underground AC = sqrt(2)*Power Transmitted/(Current Underground AC*cos(Phase Difference)) to calculate the Maximum Voltage Underground AC, The Maximum Voltage using Load Current (2 phase 4 wire US) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition. Maximum Voltage Underground AC is denoted by Vm symbol.

How to calculate Maximum Voltage using Load Current (2 Phase 4 Wire US) using this online calculator? To use this online calculator for Maximum Voltage using Load Current (2 Phase 4 Wire US), enter Power Transmitted (P), Current Underground AC (I) & Phase Difference (Φ) and hit the calculate button. Here is how the Maximum Voltage using Load Current (2 Phase 4 Wire US) calculation can be explained with given input values -> 54.43311 = sqrt(2)*300/(9*cos(0.5235987755982)).

FAQ

What is Maximum Voltage using Load Current (2 Phase 4 Wire US)?
The Maximum Voltage using Load Current (2 phase 4 wire US) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition and is represented as Vm = sqrt(2)*P/(I*cos(Φ)) or Maximum Voltage Underground AC = sqrt(2)*Power Transmitted/(Current Underground AC*cos(Phase Difference)). Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work, Current Underground AC is defined as the current flowing through the overhead ac supply wire & Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
How to calculate Maximum Voltage using Load Current (2 Phase 4 Wire US)?
The Maximum Voltage using Load Current (2 phase 4 wire US) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition is calculated using Maximum Voltage Underground AC = sqrt(2)*Power Transmitted/(Current Underground AC*cos(Phase Difference)). To calculate Maximum Voltage using Load Current (2 Phase 4 Wire US), you need Power Transmitted (P), Current Underground AC (I) & Phase Difference (Φ). With our tool, you need to enter the respective value for Power Transmitted, Current Underground AC & Phase Difference and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Maximum Voltage Underground AC?
In this formula, Maximum Voltage Underground AC uses Power Transmitted, Current Underground AC & Phase Difference. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Maximum Voltage Underground AC = (2*Power Transmitted/cos(Phase Difference))*sqrt(Resistivity*Length of Underground AC Wire/(Line Losses*Area of Underground AC Wire))
  • Maximum Voltage Underground AC = (2*Power Transmitted/cos(Phase Difference))*sqrt(Resistance Underground AC/(Line Losses))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!