Maximum Voltage(Single-Phase Three-Wire OS) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximum Voltage Overhead AC = (2)*Voltage Overhead AC
Vm = (2)*Vac
This formula uses 2 Variables
Variables Used
Maximum Voltage Overhead AC - (Measured in Volt) - Maximum Voltage Overhead AC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
Voltage Overhead AC - (Measured in Volt) - Voltage Overhead AC is defined as the amount of work or force required to start the conduction of current within a line.
STEP 1: Convert Input(s) to Base Unit
Voltage Overhead AC: 180 Volt --> 180 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vm = (2)*Vac --> (2)*180
Evaluating ... ...
Vm = 360
STEP 3: Convert Result to Output's Unit
360 Volt --> No Conversion Required
FINAL ANSWER
360 Volt <-- Maximum Voltage Overhead AC
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Current and Voltage Calculators

Maximum Voltage using Area of X-Section(Single-Phase Three-Wire OS)
​ LaTeX ​ Go Maximum Voltage Overhead AC = sqrt((Length of Overhead AC Wire*Resistivity*(Power Transmitted^2))/(Area of Overhead AC Wire*Line Losses*((cos(Phase Difference))^2)))
RMS Voltage using Area of X-Section(Single-Phase Three-Wire OS)
​ LaTeX ​ Go Root Mean Square Voltage = sqrt((2*Length of Overhead AC Wire*Resistivity*(Power Transmitted^2))/(Area of Overhead AC Wire*Line Losses*((cos(Phase Difference))^2)))
Load Current(Single-Phase Three-Wire OS)
​ LaTeX ​ Go Current Overhead AC = Power Transmitted/(Maximum Voltage Overhead AC*cos(Phase Difference)*sqrt(2))
Maximum Voltage(Single-Phase Three-Wire OS)
​ LaTeX ​ Go Maximum Voltage Overhead AC = (2)*Voltage Overhead AC

Maximum Voltage(Single-Phase Three-Wire OS) Formula

​LaTeX ​Go
Maximum Voltage Overhead AC = (2)*Voltage Overhead AC
Vm = (2)*Vac

What is the value of maximum voltage and volume of conductor material in 1-phase 3-wire system?

The volume of conductor material required in this system is (5/8)cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is 2vm so that r.m.s. value of voltage between them is √2vm.

How to Calculate Maximum Voltage(Single-Phase Three-Wire OS)?

Maximum Voltage(Single-Phase Three-Wire OS) calculator uses Maximum Voltage Overhead AC = (2)*Voltage Overhead AC to calculate the Maximum Voltage Overhead AC, The Maximum Voltage(single-Phase three-Wire OS) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition. Maximum Voltage Overhead AC is denoted by Vm symbol.

How to calculate Maximum Voltage(Single-Phase Three-Wire OS) using this online calculator? To use this online calculator for Maximum Voltage(Single-Phase Three-Wire OS), enter Voltage Overhead AC (Vac) and hit the calculate button. Here is how the Maximum Voltage(Single-Phase Three-Wire OS) calculation can be explained with given input values -> 360 = (2)*180.

FAQ

What is Maximum Voltage(Single-Phase Three-Wire OS)?
The Maximum Voltage(single-Phase three-Wire OS) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition and is represented as Vm = (2)*Vac or Maximum Voltage Overhead AC = (2)*Voltage Overhead AC. Voltage Overhead AC is defined as the amount of work or force required to start the conduction of current within a line.
How to calculate Maximum Voltage(Single-Phase Three-Wire OS)?
The Maximum Voltage(single-Phase three-Wire OS) formula is defined as the highest voltage rating for electrical devices and equipment that can be used with the voltage definition is calculated using Maximum Voltage Overhead AC = (2)*Voltage Overhead AC. To calculate Maximum Voltage(Single-Phase Three-Wire OS), you need Voltage Overhead AC (Vac). With our tool, you need to enter the respective value for Voltage Overhead AC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Maximum Voltage Overhead AC?
In this formula, Maximum Voltage Overhead AC uses Voltage Overhead AC. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Maximum Voltage Overhead AC = sqrt((Length of Overhead AC Wire*Resistivity*(Power Transmitted^2))/(Area of Overhead AC Wire*Line Losses*((cos(Phase Difference))^2)))
  • Maximum Voltage Overhead AC = Power Transmitted/(sqrt(2)*cos(Phase Difference))
  • Maximum Voltage Overhead AC = (Power Transmitted/cos(Phase Difference))*sqrt(Resistivity*Length of Overhead AC Wire/(Area of Overhead AC Wire*Line Losses))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!