Maximum Vapour Pressure given Evaporation Loss Per Month Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximum Vapour Pressure = Actual Vapour Pressure+(Evaporation Loss per Month/(Meyer's Constant*(1+(Mean Wind Velocity/16))))
V = v+(Em/(C*(1+(u/16))))
This formula uses 5 Variables
Variables Used
Maximum Vapour Pressure - (Measured in Centimeter Mercury (0 °C)) - The Maximum Vapour Pressure refers to the highest pressure exerted by a vapour in equilibrium with its liquid at a given temperature, often measured in cm Hg or kPa.
Actual Vapour Pressure - (Measured in Centimeter Mercury (0 °C)) - The Actual vapour pressure refers to the pressure exerted by the water vapour present in the air, reflecting the current humidity and temperature, typically measured in cm Hg or kPa.
Evaporation Loss per Month - (Measured in Meter) - Evaporation Loss per Month refer to the amount of water that transitions from liquid to vapor and escapes into the atmosphere over a specific time period, typically measured on a monthly basis.
Meyer's Constant - The Meyer's Constant refers to an empirical coefficient in the Meyer evaporation formula, 1.1 for deep water and 1.5 for shallow water.
Mean Wind Velocity - (Measured in Meter per Second) - Mean Wind Velocity refers to the wind in kilometers per hour at a height of about 9 meters above the ground.
STEP 1: Convert Input(s) to Base Unit
Actual Vapour Pressure: 0.4 Centimeter Mercury (0 °C) --> 0.4 Centimeter Mercury (0 °C) No Conversion Required
Evaporation Loss per Month: 8.2 Centimeter --> 0.082 Meter (Check conversion ​here)
Meyer's Constant: 0.36 --> No Conversion Required
Mean Wind Velocity: 8 Kilometer per Hour --> 2.22222222222222 Meter per Second (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
V = v+(Em/(C*(1+(u/16)))) --> 0.4+(0.082/(0.36*(1+(2.22222222222222/16))))
Evaluating ... ...
V = 0.6
STEP 3: Convert Result to Output's Unit
799.932 Pascal -->0.6 Centimeter Mercury (0 °C) (Check conversion ​here)
FINAL ANSWER
0.6 Centimeter Mercury (0 °C) <-- Maximum Vapour Pressure
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Evaporation and Transpiration Calculators

Monthly Mean Wind Velocity given Evaporation Loss Per Month
​ LaTeX ​ Go Mean Wind Velocity = ((Evaporation Loss per Month/(Meyer's Constant*(Maximum Vapour Pressure-Actual Vapour Pressure)))-1)*16
Maximum Vapour Pressure given Evaporation Loss Per Month
​ LaTeX ​ Go Maximum Vapour Pressure = Actual Vapour Pressure+(Evaporation Loss per Month/(Meyer's Constant*(1+(Mean Wind Velocity/16))))
Actual Vapour Pressure given Evaporation Loss Per Month
​ LaTeX ​ Go Actual Vapour Pressure = Maximum Vapour Pressure-(Evaporation Loss per Month/(Meyer's Constant*(1+(Mean Wind Velocity/16))))
Evaporation Loss Per Month
​ LaTeX ​ Go Evaporation Loss per Month = Meyer's Constant*(Maximum Vapour Pressure-Actual Vapour Pressure)*(1+(Mean Wind Velocity/16))

Maximum Vapour Pressure given Evaporation Loss Per Month Formula

​LaTeX ​Go
Maximum Vapour Pressure = Actual Vapour Pressure+(Evaporation Loss per Month/(Meyer's Constant*(1+(Mean Wind Velocity/16))))
V = v+(Em/(C*(1+(u/16))))

What is Vapour Pressure ?

Vapour pressure is a measure of the tendency of a material to change into the gaseous or vapour state, and it increases with temperature. The temperature at which the vapour pressure at the surface of a liquid becomes equal to the pressure exerted by the surroundings is called the boiling point of the liquid.

How to Calculate Maximum Vapour Pressure given Evaporation Loss Per Month?

Maximum Vapour Pressure given Evaporation Loss Per Month calculator uses Maximum Vapour Pressure = Actual Vapour Pressure+(Evaporation Loss per Month/(Meyer's Constant*(1+(Mean Wind Velocity/16)))) to calculate the Maximum Vapour Pressure, The Maximum Vapour Pressure given Evaporation Loss Per Month is defined as the highest pressure exerted by a vapor in equilibrium with its liquid at a given temperature, often measured in cm Hg or kPa. Maximum Vapour Pressure is denoted by V symbol.

How to calculate Maximum Vapour Pressure given Evaporation Loss Per Month using this online calculator? To use this online calculator for Maximum Vapour Pressure given Evaporation Loss Per Month, enter Actual Vapour Pressure (v), Evaporation Loss per Month (Em), Meyer's Constant (C) & Mean Wind Velocity (u) and hit the calculate button. Here is how the Maximum Vapour Pressure given Evaporation Loss Per Month calculation can be explained with given input values -> 0.0003 = 533.288+(0.082/(0.36*(1+(2.22222222222222/16)))).

FAQ

What is Maximum Vapour Pressure given Evaporation Loss Per Month?
The Maximum Vapour Pressure given Evaporation Loss Per Month is defined as the highest pressure exerted by a vapor in equilibrium with its liquid at a given temperature, often measured in cm Hg or kPa and is represented as V = v+(Em/(C*(1+(u/16)))) or Maximum Vapour Pressure = Actual Vapour Pressure+(Evaporation Loss per Month/(Meyer's Constant*(1+(Mean Wind Velocity/16)))). The Actual vapour pressure refers to the pressure exerted by the water vapour present in the air, reflecting the current humidity and temperature, typically measured in cm Hg or kPa, Evaporation Loss per Month refer to the amount of water that transitions from liquid to vapor and escapes into the atmosphere over a specific time period, typically measured on a monthly basis, The Meyer's Constant refers to an empirical coefficient in the Meyer evaporation formula, 1.1 for deep water and 1.5 for shallow water & Mean Wind Velocity refers to the wind in kilometers per hour at a height of about 9 meters above the ground.
How to calculate Maximum Vapour Pressure given Evaporation Loss Per Month?
The Maximum Vapour Pressure given Evaporation Loss Per Month is defined as the highest pressure exerted by a vapor in equilibrium with its liquid at a given temperature, often measured in cm Hg or kPa is calculated using Maximum Vapour Pressure = Actual Vapour Pressure+(Evaporation Loss per Month/(Meyer's Constant*(1+(Mean Wind Velocity/16)))). To calculate Maximum Vapour Pressure given Evaporation Loss Per Month, you need Actual Vapour Pressure (v), Evaporation Loss per Month (Em), Meyer's Constant (C) & Mean Wind Velocity (u). With our tool, you need to enter the respective value for Actual Vapour Pressure, Evaporation Loss per Month, Meyer's Constant & Mean Wind Velocity and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Maximum Vapour Pressure?
In this formula, Maximum Vapour Pressure uses Actual Vapour Pressure, Evaporation Loss per Month, Meyer's Constant & Mean Wind Velocity. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Maximum Vapour Pressure = Actual Vapour Pressure+(Evaporation Loss per Day/(Rohwer's Formula Constant*(1.465-(0.00732*Atmospheric Pressure))*(0.44+(0.0732*Mean Wind Velocity))))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!