Maximum Permissible Eccentricity for Tied Columns Solution

STEP 0: Pre-Calculation Summary
Formula Used
Maximum Permissible Eccentricity = (0.67*Area Ratio of Cross Sectional Area to Gross Area*Force Ratio of Strengths of Reinforcements*Column Diameter+0.17)*Distance from Compression to Tensile Reinforcement
eb = (0.67*pg*m*D+0.17)*d
This formula uses 5 Variables
Variables Used
Maximum Permissible Eccentricity - (Measured in Centimeter) - Maximum Permissible Eccentricity is the maximum permissible amount by which elliptical orbit deviates from a circle.
Area Ratio of Cross Sectional Area to Gross Area - Area Ratio of Cross Sectional Area to Gross Area is the ratio of cross-sectional area of vertical reinforcing steel to gross area of column.
Force Ratio of Strengths of Reinforcements - Force Ratio of Strengths of Reinforcements is the ratio of yield strength of reinforcing steel to 0.85 times 28 day compressive strength of concrete.
Column Diameter - (Measured in Centimeter) - Column Diameter is minimum size of column used in construction irrespective of small building is 9″ X 12″ (225mm X300mm).
Distance from Compression to Tensile Reinforcement - (Measured in Centimeter) - Distance from Compression to Tensile Reinforcement is defined as the distance from extreme compression surface to the centroid of tensile reinforcement, in (mm).
STEP 1: Convert Input(s) to Base Unit
Area Ratio of Cross Sectional Area to Gross Area: 8.01 --> No Conversion Required
Force Ratio of Strengths of Reinforcements: 0.41 --> No Conversion Required
Column Diameter: 10.01 Meter --> 1001 Centimeter (Check conversion ​here)
Distance from Compression to Tensile Reinforcement: 20.001 Millimeter --> 2.0001 Centimeter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
eb = (0.67*pg*m*D+0.17)*d --> (0.67*8.01*0.41*1001+0.17)*2.0001
Evaluating ... ...
eb = 4405.6549657347
STEP 3: Convert Result to Output's Unit
44.056549657347 Meter --> No Conversion Required
FINAL ANSWER
44.056549657347 44.05655 Meter <-- Maximum Permissible Eccentricity
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Rudrani Tidke
Cummins College of Engineering for Women (CCEW), Pune
Rudrani Tidke has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Design Under Axial Compression with Biaxial Bending Calculators

Maximum Permissible Eccentricity for Tied Columns
​ LaTeX ​ Go Maximum Permissible Eccentricity = (0.67*Area Ratio of Cross Sectional Area to Gross Area*Force Ratio of Strengths of Reinforcements*Column Diameter+0.17)*Distance from Compression to Tensile Reinforcement
Circle Diameter given Maximum Permissible Eccentricity for Spiral Columns
​ LaTeX ​ Go Column Diameter = (Maximum Permissible Eccentricity-0.14*Overall Depth of Column)/(0.43*Area Ratio of Cross Sectional Area to Gross Area*Force Ratio of Strengths of Reinforcements)
Column Diameter given Maximum Permissible Eccentricity for Spiral Columns
​ LaTeX ​ Go Overall Depth of Column = (Maximum Permissible Eccentricity-0.43*Area Ratio of Cross Sectional Area to Gross Area*Force Ratio of Strengths of Reinforcements*Column Diameter)/0.14
Maximum Permissible Eccentricity for Spiral Columns
​ LaTeX ​ Go Maximum Permissible Eccentricity = 0.43*Area Ratio of Cross Sectional Area to Gross Area*Force Ratio of Strengths of Reinforcements*Column Diameter+0.14*Overall Depth of Column

Maximum Permissible Eccentricity for Tied Columns Formula

​LaTeX ​Go
Maximum Permissible Eccentricity = (0.67*Area Ratio of Cross Sectional Area to Gross Area*Force Ratio of Strengths of Reinforcements*Column Diameter+0.17)*Distance from Compression to Tensile Reinforcement
eb = (0.67*pg*m*D+0.17)*d

What is Limit of Eccentricity?

Some structures like concrete column, dams, etc. are weak in tensions. Due to eccentric loading they are subjected to bending stress and its results in occurrence of tension condition. This maximum eccentricity up to which section is losses its compression is called as 'Limit of Eccentricity'

How to Calculate Maximum Permissible Eccentricity for Tied Columns?

Maximum Permissible Eccentricity for Tied Columns calculator uses Maximum Permissible Eccentricity = (0.67*Area Ratio of Cross Sectional Area to Gross Area*Force Ratio of Strengths of Reinforcements*Column Diameter+0.17)*Distance from Compression to Tensile Reinforcement to calculate the Maximum Permissible Eccentricity, The Maximum Permissible Eccentricity for Tied Columns formula is defined as a measure of the maximum permissible amount by which elliptical orbit deviates from a circle. Maximum Permissible Eccentricity is denoted by eb symbol.

How to calculate Maximum Permissible Eccentricity for Tied Columns using this online calculator? To use this online calculator for Maximum Permissible Eccentricity for Tied Columns, enter Area Ratio of Cross Sectional Area to Gross Area (pg), Force Ratio of Strengths of Reinforcements (m), Column Diameter (D) & Distance from Compression to Tensile Reinforcement (d) and hit the calculate button. Here is how the Maximum Permissible Eccentricity for Tied Columns calculation can be explained with given input values -> 0.433187 = (0.67*8.01*0.41*10.01+0.17)*0.020001.

FAQ

What is Maximum Permissible Eccentricity for Tied Columns?
The Maximum Permissible Eccentricity for Tied Columns formula is defined as a measure of the maximum permissible amount by which elliptical orbit deviates from a circle and is represented as eb = (0.67*pg*m*D+0.17)*d or Maximum Permissible Eccentricity = (0.67*Area Ratio of Cross Sectional Area to Gross Area*Force Ratio of Strengths of Reinforcements*Column Diameter+0.17)*Distance from Compression to Tensile Reinforcement. Area Ratio of Cross Sectional Area to Gross Area is the ratio of cross-sectional area of vertical reinforcing steel to gross area of column, Force Ratio of Strengths of Reinforcements is the ratio of yield strength of reinforcing steel to 0.85 times 28 day compressive strength of concrete, Column Diameter is minimum size of column used in construction irrespective of small building is 9″ X 12″ (225mm X300mm) & Distance from Compression to Tensile Reinforcement is defined as the distance from extreme compression surface to the centroid of tensile reinforcement, in (mm).
How to calculate Maximum Permissible Eccentricity for Tied Columns?
The Maximum Permissible Eccentricity for Tied Columns formula is defined as a measure of the maximum permissible amount by which elliptical orbit deviates from a circle is calculated using Maximum Permissible Eccentricity = (0.67*Area Ratio of Cross Sectional Area to Gross Area*Force Ratio of Strengths of Reinforcements*Column Diameter+0.17)*Distance from Compression to Tensile Reinforcement. To calculate Maximum Permissible Eccentricity for Tied Columns, you need Area Ratio of Cross Sectional Area to Gross Area (pg), Force Ratio of Strengths of Reinforcements (m), Column Diameter (D) & Distance from Compression to Tensile Reinforcement (d). With our tool, you need to enter the respective value for Area Ratio of Cross Sectional Area to Gross Area, Force Ratio of Strengths of Reinforcements, Column Diameter & Distance from Compression to Tensile Reinforcement and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Maximum Permissible Eccentricity?
In this formula, Maximum Permissible Eccentricity uses Area Ratio of Cross Sectional Area to Gross Area, Force Ratio of Strengths of Reinforcements, Column Diameter & Distance from Compression to Tensile Reinforcement. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Maximum Permissible Eccentricity = 0.43*Area Ratio of Cross Sectional Area to Gross Area*Force Ratio of Strengths of Reinforcements*Column Diameter+0.14*Overall Depth of Column
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!