Maximum Input Common-Mode Range of MOS Differential Amplifier Solution

STEP 0: Pre-Calculation Summary
Formula Used
Common-Mode Range = Threshold Voltage+Load Voltage-(1/2*Load Resistance)
Vcmr = Vt+VL-(1/2*RL)
This formula uses 4 Variables
Variables Used
Common-Mode Range - (Measured in Volt) - The common-mode range is for signal processing devices with differential inputs, such as an op-amp.
Threshold Voltage - (Measured in Volt) - Threshold voltage of transistor is the minimum gate to source voltage that is needed to create a conducting path between the source and drain terminals.
Load Voltage - (Measured in Volt) - The Load Voltage is defined as the voltage between two terminals of load.
Load Resistance - (Measured in Ohm) - Load resistance of MOSFET is the effective resistance of all of the circuit elements excluding the emf source.
STEP 1: Convert Input(s) to Base Unit
Threshold Voltage: 19.5 Volt --> 19.5 Volt No Conversion Required
Load Voltage: 22.64 Volt --> 22.64 Volt No Conversion Required
Load Resistance: 0.0776 Kilohm --> 77.6 Ohm (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vcmr = Vt+VL-(1/2*RL) --> 19.5+22.64-(1/2*77.6)
Evaluating ... ...
Vcmr = 3.34
STEP 3: Convert Result to Output's Unit
3.34 Volt --> No Conversion Required
FINAL ANSWER
3.34 Volt <-- Common-Mode Range
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has created this Calculator and 600+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Differential Configuration Calculators

Minimum Input Common-Mode Range of MOS Differential Amplifier
​ LaTeX ​ Go Common-Mode Range = Threshold Voltage+Effective Voltage+Voltage between Gate and Source-Load Voltage
Maximum Input Common-Mode Range of MOS Differential Amplifier
​ LaTeX ​ Go Common-Mode Range = Threshold Voltage+Load Voltage-(1/2*Load Resistance)
Input Voltage of MOS Differential Amplifier on Small-Signal Operation
​ LaTeX ​ Go Input Voltage = Common-Mode DC Voltage+(1/2*Differential Input Signal)
Input Offset Voltage of MOS Differential Amplifier
​ LaTeX ​ Go Input Offset Voltage = Output DC Offset Voltage/Differential Gain

Maximum Input Common-Mode Range of MOS Differential Amplifier Formula

​LaTeX ​Go
Common-Mode Range = Threshold Voltage+Load Voltage-(1/2*Load Resistance)
Vcmr = Vt+VL-(1/2*RL)

Why differential amplifiers dominate modern analog ICs?

Differential amplifiers apply gain not to one input signal but to the difference between two input signals. This means that a differential amplifier naturally eliminates noise or interference that is present in both input signals. Differential amplification also suppresses common-mode signals—in other words, a DC offset that is present in both input signals will be removed, and the gain will be applied only to the signal of interest (assuming, of course, that the signal of interest is not present in both inputs). This is particularly advantageous in the context of IC design because it eliminates the need for bulky DC-blocking capacitors. The subtraction that occurs in a differential pair makes it easy to incorporate the circuit into a negative-feedback amplifier, and if you’ve read the Negative Feedback series, you know that negative feedback is about the best thing that could ever happen to an amplifier circuit.

How to Calculate Maximum Input Common-Mode Range of MOS Differential Amplifier?

Maximum Input Common-Mode Range of MOS Differential Amplifier calculator uses Common-Mode Range = Threshold Voltage+Load Voltage-(1/2*Load Resistance) to calculate the Common-Mode Range, maximum input common-mode range of MOS differential amplifier formula is for signal processing devices with differential inputs, such as op-amp, CMVR is range of common-mode signal for which amplifier's operation remains linear. Common-Mode Range is denoted by Vcmr symbol.

How to calculate Maximum Input Common-Mode Range of MOS Differential Amplifier using this online calculator? To use this online calculator for Maximum Input Common-Mode Range of MOS Differential Amplifier, enter Threshold Voltage (Vt), Load Voltage (VL) & Load Resistance (RL) and hit the calculate button. Here is how the Maximum Input Common-Mode Range of MOS Differential Amplifier calculation can be explained with given input values -> 13.34 = 19.5+22.64-(1/2*77.6).

FAQ

What is Maximum Input Common-Mode Range of MOS Differential Amplifier?
maximum input common-mode range of MOS differential amplifier formula is for signal processing devices with differential inputs, such as op-amp, CMVR is range of common-mode signal for which amplifier's operation remains linear and is represented as Vcmr = Vt+VL-(1/2*RL) or Common-Mode Range = Threshold Voltage+Load Voltage-(1/2*Load Resistance). Threshold voltage of transistor is the minimum gate to source voltage that is needed to create a conducting path between the source and drain terminals, The Load Voltage is defined as the voltage between two terminals of load & Load resistance of MOSFET is the effective resistance of all of the circuit elements excluding the emf source.
How to calculate Maximum Input Common-Mode Range of MOS Differential Amplifier?
maximum input common-mode range of MOS differential amplifier formula is for signal processing devices with differential inputs, such as op-amp, CMVR is range of common-mode signal for which amplifier's operation remains linear is calculated using Common-Mode Range = Threshold Voltage+Load Voltage-(1/2*Load Resistance). To calculate Maximum Input Common-Mode Range of MOS Differential Amplifier, you need Threshold Voltage (Vt), Load Voltage (VL) & Load Resistance (RL). With our tool, you need to enter the respective value for Threshold Voltage, Load Voltage & Load Resistance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Common-Mode Range?
In this formula, Common-Mode Range uses Threshold Voltage, Load Voltage & Load Resistance. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Common-Mode Range = Threshold Voltage+Effective Voltage+Voltage between Gate and Source-Load Voltage