Mass of Solids Removed with Effluent Per Day Solution

STEP 0: Pre-Calculation Summary
Formula Used
Mass of Solids = (Sewage Discharge-Volume of Wasted Sludge per day)*Concentration of Solids in Effluent
Ms = (Qs-Qw)*XE
This formula uses 4 Variables
Variables Used
Mass of Solids - (Measured in Kilogram) - Mass of Solids means the actual weight of the solid particle present in the sewage.
Sewage Discharge - (Measured in Cubic Meter per Second) - Sewage Discharge is the flow rate of sewage when it is being discharged in the river.
Volume of Wasted Sludge per day - (Measured in Cubic Meter per Second) - Volume of Wasted Sludge per day is the amount of sludge that is removed from a wastewater treatment process within a 24-hour period.
Concentration of Solids in Effluent - (Measured in Kilogram per Cubic Meter) - Concentration of Solids in Effluent is the amount of solid particles, both suspended and dissolved, present in a liquid effluent (wastewater or other discharged liquid).
STEP 1: Convert Input(s) to Base Unit
Sewage Discharge: 10 Cubic Meter per Second --> 10 Cubic Meter per Second No Conversion Required
Volume of Wasted Sludge per day: 9.5 Cubic Meter per Second --> 9.5 Cubic Meter per Second No Conversion Required
Concentration of Solids in Effluent: 10 Milligram per Liter --> 0.01 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ms = (Qs-Qw)*XE --> (10-9.5)*0.01
Evaluating ... ...
Ms = 0.005
STEP 3: Convert Result to Output's Unit
0.005 Kilogram -->5000 Milligram (Check conversion ​here)
FINAL ANSWER
5000 Milligram <-- Mass of Solids
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Mass of Solid in Reactor Calculators

Mass of Solids Removed with Wasted Sludge Per Day
​ LaTeX ​ Go Mass of Solids = Volume of Wasted Sludge per day*Concentration of Solids in Returned Sludge
Mass of Solids Leaving System Per Day
​ LaTeX ​ Go Mass of Solids Leaving the System = Mass of Suspended Solids/Sludge Age
Mass of Suspended Solids in System
​ LaTeX ​ Go Mass of Suspended Solids = Mass of Solids Leaving the System*Sludge Age
Mass of Solids in Reactor
​ LaTeX ​ Go Mass of Solids = Volume of Reactor Tank*Mixed Liquor Suspended Solids

Mass of Solids Removed with Effluent Per Day Formula

​LaTeX ​Go
Mass of Solids = (Sewage Discharge-Volume of Wasted Sludge per day)*Concentration of Solids in Effluent
Ms = (Qs-Qw)*XE

What is Sewage?

Sewage, or domestic/municipal wastewater, is a type of wastewater that is produced by a community of people. ... Sewage usually travels from a building's plumbing either into a sewer, which will carry it elsewhere, or into an onsite sewage facility (of which there are many kinds).

How to Calculate Mass of Solids Removed with Effluent Per Day?

Mass of Solids Removed with Effluent Per Day calculator uses Mass of Solids = (Sewage Discharge-Volume of Wasted Sludge per day)*Concentration of Solids in Effluent to calculate the Mass of Solids, The Mass of Solids Removed with Effluent Per Day formula is defined as the calculation of mass of solids removed with effluent per day when we have prior information of other parameters used. Mass of Solids is denoted by Ms symbol.

How to calculate Mass of Solids Removed with Effluent Per Day using this online calculator? To use this online calculator for Mass of Solids Removed with Effluent Per Day, enter Sewage Discharge (Qs), Volume of Wasted Sludge per day (Qw) & Concentration of Solids in Effluent (XE) and hit the calculate button. Here is how the Mass of Solids Removed with Effluent Per Day calculation can be explained with given input values -> 1.5E+9 = (10-9.5)*0.01.

FAQ

What is Mass of Solids Removed with Effluent Per Day?
The Mass of Solids Removed with Effluent Per Day formula is defined as the calculation of mass of solids removed with effluent per day when we have prior information of other parameters used and is represented as Ms = (Qs-Qw)*XE or Mass of Solids = (Sewage Discharge-Volume of Wasted Sludge per day)*Concentration of Solids in Effluent. Sewage Discharge is the flow rate of sewage when it is being discharged in the river, Volume of Wasted Sludge per day is the amount of sludge that is removed from a wastewater treatment process within a 24-hour period & Concentration of Solids in Effluent is the amount of solid particles, both suspended and dissolved, present in a liquid effluent (wastewater or other discharged liquid).
How to calculate Mass of Solids Removed with Effluent Per Day?
The Mass of Solids Removed with Effluent Per Day formula is defined as the calculation of mass of solids removed with effluent per day when we have prior information of other parameters used is calculated using Mass of Solids = (Sewage Discharge-Volume of Wasted Sludge per day)*Concentration of Solids in Effluent. To calculate Mass of Solids Removed with Effluent Per Day, you need Sewage Discharge (Qs), Volume of Wasted Sludge per day (Qw) & Concentration of Solids in Effluent (XE). With our tool, you need to enter the respective value for Sewage Discharge, Volume of Wasted Sludge per day & Concentration of Solids in Effluent and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Mass of Solids?
In this formula, Mass of Solids uses Sewage Discharge, Volume of Wasted Sludge per day & Concentration of Solids in Effluent. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Mass of Solids = Volume of Reactor Tank*Mixed Liquor Suspended Solids
  • Mass of Solids = Volume of Wasted Sludge per day*Concentration of Solids in Returned Sludge
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!