Magnetic Flux of DC Machine given Torque Solution

STEP 0: Pre-Calculation Summary
Formula Used
Magnetic Flux = Torque/(Machine Constant*Armature Current)
Φ = τ/(Kf*Ia)
This formula uses 4 Variables
Variables Used
Magnetic Flux - (Measured in Weber) - Magnetic Flux refers to the lines of magnetic force that pass through the magnetic circuit of the machine. The magnetic flux is created by field winding that is wound around pole shoes.
Torque - (Measured in Newton Meter) - Torque is the measure of the turning force produced by the armature. It is produced by the interaction between the magnetic field of the stator and the current flowing through armature.
Machine Constant - Machine Constant refers to the parameter which usually has a constant value for a particular type of dc machine.
Armature Current - (Measured in Ampere) - Armature Current is defined as the current developed in the armature of an electrical DC generator due to movement of rotor.
STEP 1: Convert Input(s) to Base Unit
Torque: 0.62 Newton Meter --> 0.62 Newton Meter No Conversion Required
Machine Constant: 2.864 --> No Conversion Required
Armature Current: 0.75 Ampere --> 0.75 Ampere No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Φ = τ/(Kf*Ia) --> 0.62/(2.864*0.75)
Evaluating ... ...
Φ = 0.288640595903166
STEP 3: Convert Result to Output's Unit
0.288640595903166 Weber --> No Conversion Required
FINAL ANSWER
0.288640595903166 0.288641 Weber <-- Magnetic Flux
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

DC Machine Characterstics Calculators

Design Constant of DC Machine
​ LaTeX ​ Go Machine Constant = (Number of Conductors*Number of Poles)/(2*pi*Number of Parallel Paths)
Angular Speed of DC Machine using Kf
​ LaTeX ​ Go Angular Speed = Armature Voltage/(Machine Constant*Magnetic Flux*Armature Current)
Front Pitch for DC Machine
​ LaTeX ​ Go Front Pitch = ((2*Number of Slots)/Number of Poles)-1
Back Pitch for DC Machine
​ LaTeX ​ Go Back Pitch = ((2*Number of Slots)/Number of Poles)+1

Magnetic Flux of DC Machine given Torque Formula

​LaTeX ​Go
Magnetic Flux = Torque/(Machine Constant*Armature Current)
Φ = τ/(Kf*Ia)

What are the features of DC series motor?

In a DC series motor, the field winding is connected in series with the armature and hence carries the full armature current. When the load on shaft of the motor is increased, the armature current also increases. Hence, the flux in a series motor increases with the increase in the armature current and vice-versa.

How to Calculate Magnetic Flux of DC Machine given Torque?

Magnetic Flux of DC Machine given Torque calculator uses Magnetic Flux = Torque/(Machine Constant*Armature Current) to calculate the Magnetic Flux, The Magnetic Flux of DC Machine given Torque formula is defined as the number of magnetic field lines (also called "magnetic flux density") passing through a surface (such as a loop of wire). Magnetic Flux is denoted by Φ symbol.

How to calculate Magnetic Flux of DC Machine given Torque using this online calculator? To use this online calculator for Magnetic Flux of DC Machine given Torque, enter Torque (τ), Machine Constant (Kf) & Armature Current (Ia) and hit the calculate button. Here is how the Magnetic Flux of DC Machine given Torque calculation can be explained with given input values -> 0.288641 = 0.62/(2.864*0.75).

FAQ

What is Magnetic Flux of DC Machine given Torque?
The Magnetic Flux of DC Machine given Torque formula is defined as the number of magnetic field lines (also called "magnetic flux density") passing through a surface (such as a loop of wire) and is represented as Φ = τ/(Kf*Ia) or Magnetic Flux = Torque/(Machine Constant*Armature Current). Torque is the measure of the turning force produced by the armature. It is produced by the interaction between the magnetic field of the stator and the current flowing through armature, Machine Constant refers to the parameter which usually has a constant value for a particular type of dc machine & Armature Current is defined as the current developed in the armature of an electrical DC generator due to movement of rotor.
How to calculate Magnetic Flux of DC Machine given Torque?
The Magnetic Flux of DC Machine given Torque formula is defined as the number of magnetic field lines (also called "magnetic flux density") passing through a surface (such as a loop of wire) is calculated using Magnetic Flux = Torque/(Machine Constant*Armature Current). To calculate Magnetic Flux of DC Machine given Torque, you need Torque (τ), Machine Constant (Kf) & Armature Current (Ia). With our tool, you need to enter the respective value for Torque, Machine Constant & Armature Current and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!