Magnetic Field of Solenoid Solution

STEP 0: Pre-Calculation Summary
Formula Used
Solenoid Magnetic Field = ([Permeability-vacuum]*Number of Coil Turn*Electric Current)/Solenoid Length
Hs = ([Permeability-vacuum]*N*I)/L
This formula uses 1 Constants, 4 Variables
Constants Used
[Permeability-vacuum] - Permeability of vacuum Value Taken As 1.2566E-6
Variables Used
Solenoid Magnetic Field - (Measured in Tesla) - Solenoid Magnetic Field is the magnetic field generated inside a coil of wire when an electric current passes through it, characterized by uniformity and directed along the coil's axis.
Number of Coil Turn - Number of Coil Turn refers to the count of loops or windings in an electrical coil. It directly impacts the strength of the magnetic field and the induced voltage.
Electric Current - (Measured in Ampere) - Electric Current is defined as the rate at which electric charge flows through a conductor or a circuit, typically measured in amperes (A).
Solenoid Length - (Measured in Meter) - Solenoid Length refers to the physical extent of a cylindrical coil of wire used to generate a magnetic field when an electric current passes through it.
STEP 1: Convert Input(s) to Base Unit
Number of Coil Turn: 23 --> No Conversion Required
Electric Current: 2.1 Ampere --> 2.1 Ampere No Conversion Required
Solenoid Length: 11.55 Meter --> 11.55 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Hs = ([Permeability-vacuum]*N*I)/L --> ([Permeability-vacuum]*23*2.1)/11.55
Evaluating ... ...
Hs = 5.25502771145929E-06
STEP 3: Convert Result to Output's Unit
5.25502771145929E-06 Tesla --> No Conversion Required
FINAL ANSWER
5.25502771145929E-06 5.3E-6 Tesla <-- Solenoid Magnetic Field
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Magnetic Instruments Calculators

Number of Turns in Solenoid
​ LaTeX ​ Go Number of Coil Turn = (Solenoid Magnetic Field*Solenoid Length)/(Electric Current*[Permeability-vacuum])
Magnetic Field of Solenoid
​ LaTeX ​ Go Solenoid Magnetic Field = ([Permeability-vacuum]*Number of Coil Turn*Electric Current)/Solenoid Length
Reluctance of Magnetic Circuit
​ LaTeX ​ Go Magnetic Circuit Reluctance = Magnetomotive Force/Magnetic Flux
Magneto Motive Force(MMF)
​ LaTeX ​ Go Magnetomotive Force = Magnetic Flux*Magnetic Circuit Reluctance

Magnetic Field of Solenoid Formula

​LaTeX ​Go
Solenoid Magnetic Field = ([Permeability-vacuum]*Number of Coil Turn*Electric Current)/Solenoid Length
Hs = ([Permeability-vacuum]*N*I)/L

What is Ampere’s Law ?

Ampere’s Law states that:
“The integration of a magnetic field around a loop is directly proportional to the current enclosed in the loop.”

How to Calculate Magnetic Field of Solenoid?

Magnetic Field of Solenoid calculator uses Solenoid Magnetic Field = ([Permeability-vacuum]*Number of Coil Turn*Electric Current)/Solenoid Length to calculate the Solenoid Magnetic Field, Magnetic Field of Solenoid is generated when an electric current flows through a device that consists of a tightly wound coil of wire in the form of a cylindrical shape. It is calculated as per Ampere’s Law. Solenoid Magnetic Field is denoted by Hs symbol.

How to calculate Magnetic Field of Solenoid using this online calculator? To use this online calculator for Magnetic Field of Solenoid, enter Number of Coil Turn (N), Electric Current (I) & Solenoid Length (L) and hit the calculate button. Here is how the Magnetic Field of Solenoid calculation can be explained with given input values -> 5.3E-6 = ([Permeability-vacuum]*23*2.1)/11.55.

FAQ

What is Magnetic Field of Solenoid?
Magnetic Field of Solenoid is generated when an electric current flows through a device that consists of a tightly wound coil of wire in the form of a cylindrical shape. It is calculated as per Ampere’s Law and is represented as Hs = ([Permeability-vacuum]*N*I)/L or Solenoid Magnetic Field = ([Permeability-vacuum]*Number of Coil Turn*Electric Current)/Solenoid Length. Number of Coil Turn refers to the count of loops or windings in an electrical coil. It directly impacts the strength of the magnetic field and the induced voltage, Electric Current is defined as the rate at which electric charge flows through a conductor or a circuit, typically measured in amperes (A) & Solenoid Length refers to the physical extent of a cylindrical coil of wire used to generate a magnetic field when an electric current passes through it.
How to calculate Magnetic Field of Solenoid?
Magnetic Field of Solenoid is generated when an electric current flows through a device that consists of a tightly wound coil of wire in the form of a cylindrical shape. It is calculated as per Ampere’s Law is calculated using Solenoid Magnetic Field = ([Permeability-vacuum]*Number of Coil Turn*Electric Current)/Solenoid Length. To calculate Magnetic Field of Solenoid, you need Number of Coil Turn (N), Electric Current (I) & Solenoid Length (L). With our tool, you need to enter the respective value for Number of Coil Turn, Electric Current & Solenoid Length and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!