Load using Area of Lowest Column of Structure Solution

STEP 0: Pre-Calculation Summary
Formula Used
Columns Axial Load = Allowable Bearing Pressure*Area of Foundation
P = Fp*A
This formula uses 3 Variables
Variables Used
Columns Axial Load - (Measured in Newton) - Columns Axial Load is defined as the applying a force on a column structure directly along an axis.
Allowable Bearing Pressure - (Measured in Megapascal) - Allowable Bearing Pressure is defined as the maximum soil pressure without any shear failure or settlement failure.
Area of Foundation - (Measured in Square Meter) - Area of Foundation is the horizontal surface on which a building or structure rests to distribute its weight evenly.
STEP 1: Convert Input(s) to Base Unit
Allowable Bearing Pressure: 17 Megapascal --> 17 Megapascal No Conversion Required
Area of Foundation: 3.5 Square Meter --> 3.5 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
P = Fp*A --> 17*3.5
Evaluating ... ...
P = 59.5
STEP 3: Convert Result to Output's Unit
59.5 Newton --> No Conversion Required
FINAL ANSWER
59.5 Newton <-- Columns Axial Load
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has created this Calculator and 1000+ more calculators!
Verifier Image
Verified by Alithea Fernandes
Don Bosco College of Engineering (DBCE), Goa
Alithea Fernandes has verified this Calculator and 100+ more calculators!

Allowable Stress Design Approach (AISC) Calculators

Allowable Bearing Pressure given Area of Lowest Column of Structure
​ LaTeX ​ Go Allowable Bearing Pressure = Columns Axial Load/Area of Foundation
Area of Foundation of Lowest Column of Structure
​ LaTeX ​ Go Area of Foundation = Columns Axial Load/Allowable Bearing Pressure
Load using Area of Lowest Column of Structure
​ LaTeX ​ Go Columns Axial Load = Allowable Bearing Pressure*Area of Foundation
Allowable Bearing Pressure when Full Area of Support is Occupied by Base Plate
​ LaTeX ​ Go Allowable Bearing Pressure = 0.35*28-Day Compressive Strength of Concrete

Load using Area of Lowest Column of Structure Formula

​LaTeX ​Go
Columns Axial Load = Allowable Bearing Pressure*Area of Foundation
P = Fp*A

What is the significance of Base Plate in Foundation?

The eccentricity of loading or the presence of bending moment at the column base increases the pressure on some parts of the base plate and decreases it on other parts. To compute these effects, the base plate may be assumed completely rigid so that the pressure variation on the concrete is linear.

Define a Column.

A column or pillar in architecture and structural engineering is a structural element that transmits, through compression, the weight of the structure above to other structural elements below. In other words, a column is a compression member.

How to Calculate Load using Area of Lowest Column of Structure?

Load using Area of Lowest Column of Structure calculator uses Columns Axial Load = Allowable Bearing Pressure*Area of Foundation to calculate the Columns Axial Load, The Load using Area of Lowest Column of Structure formula is defined as the heavy or bulky object that requires effort to move or lift the load. The effort is an applied force to bring the desired change to the position (push or lift) of the load. Columns Axial Load is denoted by P symbol.

How to calculate Load using Area of Lowest Column of Structure using this online calculator? To use this online calculator for Load using Area of Lowest Column of Structure, enter Allowable Bearing Pressure (Fp) & Area of Foundation (A) and hit the calculate button. Here is how the Load using Area of Lowest Column of Structure calculation can be explained with given input values -> 59.5 = 17000000*3.5.

FAQ

What is Load using Area of Lowest Column of Structure?
The Load using Area of Lowest Column of Structure formula is defined as the heavy or bulky object that requires effort to move or lift the load. The effort is an applied force to bring the desired change to the position (push or lift) of the load and is represented as P = Fp*A or Columns Axial Load = Allowable Bearing Pressure*Area of Foundation. Allowable Bearing Pressure is defined as the maximum soil pressure without any shear failure or settlement failure & Area of Foundation is the horizontal surface on which a building or structure rests to distribute its weight evenly.
How to calculate Load using Area of Lowest Column of Structure?
The Load using Area of Lowest Column of Structure formula is defined as the heavy or bulky object that requires effort to move or lift the load. The effort is an applied force to bring the desired change to the position (push or lift) of the load is calculated using Columns Axial Load = Allowable Bearing Pressure*Area of Foundation. To calculate Load using Area of Lowest Column of Structure, you need Allowable Bearing Pressure (Fp) & Area of Foundation (A). With our tool, you need to enter the respective value for Allowable Bearing Pressure & Area of Foundation and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!