How to Calculate Load Reduction Factor for Member Bent in Single Curvature?
Load Reduction Factor for Member Bent in Single Curvature calculator uses Long Column Load Reduction Factor = 1.07-(0.008*Length of Column/Radius of Gyration of Gross Concrete Area) to calculate the Long Column Load Reduction Factor, The Load Reduction Factor for Member Bent in Single Curvature formula is defined as the design of such columns considering the factor of buckling, lower value of working stresses in steel and concrete is adopted, by multiplying the general working stresses by the reduction coefficient. Long Column Load Reduction Factor is denoted by R symbol.
How to calculate Load Reduction Factor for Member Bent in Single Curvature using this online calculator? To use this online calculator for Load Reduction Factor for Member Bent in Single Curvature, enter Length of Column (l) & Radius of Gyration of Gross Concrete Area (r) and hit the calculate button. Here is how the Load Reduction Factor for Member Bent in Single Curvature calculation can be explained with given input values -> 1.033636 = 1.07-(0.008*5/1.1).