How to Calculate LLC Series Frequency of Resonant Converter?
LLC Series Frequency of Resonant Converter calculator uses Series Resonant Frequency = 1/((2*pi)*sqrt((Inductance+Parallel Resonant Inductance)*Resonant Capacitor)) to calculate the Series Resonant Frequency, LLC Series Frequency of Resonant Converter is the frequency at which the resonant tank in the converter oscillates. The LLC series frequency is an important parameter in the design and operation of LLC resonant converters, as it affects the efficiency, power handling capability, and EMI performance of the converter. LLC resonant converters are a versatile and efficient type of resonant converter that can be used in a wide range of applications. Series Resonant Frequency is denoted by Fseries symbol.
How to calculate LLC Series Frequency of Resonant Converter using this online calculator? To use this online calculator for LLC Series Frequency of Resonant Converter, enter Inductance (L), Parallel Resonant Inductance (Lr(||)) & Resonant Capacitor (Cr) and hit the calculate button. Here is how the LLC Series Frequency of Resonant Converter calculation can be explained with given input values -> 0.009202 = 1/((2*pi)*sqrt((9.56+14.66)*12.35)).