Liquid Flowrate in Rectifying Section for given Quality of Feed Solution

STEP 0: Pre-Calculation Summary
Formula Used
Liquid Flowrate in Rectifying Section = Liquid Flowrate in Stripping Section-Feed Quality*Feed Flowrate
Ln = Lm-q*F
This formula uses 4 Variables
Variables Used
Liquid Flowrate in Rectifying Section - (Measured in Mole per Second) - Liquid Flowrate in Rectifying Section refers to the molar flowrate of the liquid component traveling in the rectifying section of distillation column.
Liquid Flowrate in Stripping Section - (Measured in Mole per Second) - Liquid Flowrate in Stripping Section refers to the molar flowrate of liquid traveling through the stripping section of a distillation column.
Feed Quality - Feed Quality refers to the composition, properties, and condition of the feedstock entering the distillation column.
Feed Flowrate - (Measured in Mole per Second) - Feed Flowrate is defined as the molar flowrate of the feedstock that is sent into a distillation column.
STEP 1: Convert Input(s) to Base Unit
Liquid Flowrate in Stripping Section: 593.357 Mole per Second --> 593.357 Mole per Second No Conversion Required
Feed Quality: 1.345 --> No Conversion Required
Feed Flowrate: 217.0318 Mole per Second --> 217.0318 Mole per Second No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ln = Lm-q*F --> 593.357-1.345*217.0318
Evaluating ... ...
Ln = 301.449229
STEP 3: Convert Result to Output's Unit
301.449229 Mole per Second --> No Conversion Required
FINAL ANSWER
301.449229 301.4492 Mole per Second <-- Liquid Flowrate in Rectifying Section
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Rishi Vadodaria
Malviya National Institute Of Technology (MNIT JAIPUR ), JAIPUR
Rishi Vadodaria has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Vaibhav Mishra
DJ Sanghvi College of Engineering (DJSCE), Mumbai
Vaibhav Mishra has verified this Calculator and 200+ more calculators!

Distillation Tower Design Calculators

Column Diameter given Maximum Vapor Rate and Maximum Vapor Velocity
​ Go Column Diameter = sqrt((4*Vapor Mass Flowrate)/(pi*Vapor Density in Distillation*Maximum Allowable Vapor Velocity))
Column Diameter Based on Vapor Flowrate and Mass Velocity of Vapor
​ Go Column Diameter = ((4*Vapor Mass Flowrate)/(pi*Maximum Allowable Mass Velocity))^(1/2)
Active Area given Gas Volumetric Flow and Flow Velocity
​ Go Active Area = Volumetric Gas Flow/(Fractional Downcomer Area*Flooding Velocity)
Clearance Area under Downcomer given Weir Length and Apron Height
​ Go Clearance Area Under Downcomer = Apron Height*Weir Length

Liquid Flowrate in Rectifying Section for given Quality of Feed Formula

Liquid Flowrate in Rectifying Section = Liquid Flowrate in Stripping Section-Feed Quality*Feed Flowrate
Ln = Lm-q*F

What is Stripping section and Rectifying section in Distillation Column?

In a distillation column, which is a key unit in chemical and petrochemical processes for separating liquid mixtures into their individual components, there are two main sections: the Stripping Section (also known as the Reboiler Section) and the Rectifying Section (also known as the Condenser Section). Location: The Stripping Section is located at the bottom of the distillation column. Function: The primary function of the Stripping Section is to vaporize the components with higher boiling points from the liquid mixture. This is achieved by providing heat, often through a reboiler, which causes the liquid to boil and generate vapor. The vapor rises through the column, carrying with it the less volatile components. Location: The Rectifying Section is situated at the top of the distillation column. Function: The primary function of the Rectifying Section is to condense the vapor rising from the Stripping Section back into liquid.

How to Calculate Liquid Flowrate in Rectifying Section for given Quality of Feed?

Liquid Flowrate in Rectifying Section for given Quality of Feed calculator uses Liquid Flowrate in Rectifying Section = Liquid Flowrate in Stripping Section-Feed Quality*Feed Flowrate to calculate the Liquid Flowrate in Rectifying Section, The Liquid Flowrate in Rectifying Section for given Quality of Feed formula is defined as molar flowrate of the liquid component that travels across the rectifying section of a distillation column. Liquid Flowrate in Rectifying Section is denoted by Ln symbol.

How to calculate Liquid Flowrate in Rectifying Section for given Quality of Feed using this online calculator? To use this online calculator for Liquid Flowrate in Rectifying Section for given Quality of Feed, enter Liquid Flowrate in Stripping Section (Lm), Feed Quality (q) & Feed Flowrate (F) and hit the calculate button. Here is how the Liquid Flowrate in Rectifying Section for given Quality of Feed calculation can be explained with given input values -> 301.4492 = 593.357-1.345*217.0318.

FAQ

What is Liquid Flowrate in Rectifying Section for given Quality of Feed?
The Liquid Flowrate in Rectifying Section for given Quality of Feed formula is defined as molar flowrate of the liquid component that travels across the rectifying section of a distillation column and is represented as Ln = Lm-q*F or Liquid Flowrate in Rectifying Section = Liquid Flowrate in Stripping Section-Feed Quality*Feed Flowrate. Liquid Flowrate in Stripping Section refers to the molar flowrate of liquid traveling through the stripping section of a distillation column, Feed Quality refers to the composition, properties, and condition of the feedstock entering the distillation column & Feed Flowrate is defined as the molar flowrate of the feedstock that is sent into a distillation column.
How to calculate Liquid Flowrate in Rectifying Section for given Quality of Feed?
The Liquid Flowrate in Rectifying Section for given Quality of Feed formula is defined as molar flowrate of the liquid component that travels across the rectifying section of a distillation column is calculated using Liquid Flowrate in Rectifying Section = Liquid Flowrate in Stripping Section-Feed Quality*Feed Flowrate. To calculate Liquid Flowrate in Rectifying Section for given Quality of Feed, you need Liquid Flowrate in Stripping Section (Lm), Feed Quality (q) & Feed Flowrate (F). With our tool, you need to enter the respective value for Liquid Flowrate in Stripping Section, Feed Quality & Feed Flowrate and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Liquid Flowrate in Rectifying Section?
In this formula, Liquid Flowrate in Rectifying Section uses Liquid Flowrate in Stripping Section, Feed Quality & Feed Flowrate. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Liquid Flowrate in Rectifying Section = Liquid Flowrate in Stripping Section-Feed Quality*(Feed Flowrate)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!