Line to Neutral Current using Real Power Solution

STEP 0: Pre-Calculation Summary
Formula Used
Line to Neutral Current = Real Power/(3*cos(Phase Difference)*Line to Neutral Voltage)
Iln = P/(3*cos(Φ)*Vln)
This formula uses 1 Functions, 4 Variables
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
Variables Used
Line to Neutral Current - (Measured in Ampere) - The Line to Neutral Current is a current flow between the line to neutral.
Real Power - (Measured in Watt) - The Real Power P is the average power in watts delivered to a load. It is the only useful power. It is the actual power dissipated by the load.
Phase Difference - (Measured in Radian) - Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit.
Line to Neutral Voltage - (Measured in Volt) - The Line to Neutral Voltage (usually referred to as phase voltage) is the voltage between any of the 3 phases and the central star point which is connected to the earth.
STEP 1: Convert Input(s) to Base Unit
Real Power: 235 Watt --> 235 Watt No Conversion Required
Phase Difference: 30 Degree --> 0.5235987755982 Radian (Check conversion ​here)
Line to Neutral Voltage: 68.9 Volt --> 68.9 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Iln = P/(3*cos(Φ)*Vln) --> 235/(3*cos(0.5235987755982)*68.9)
Evaluating ... ...
Iln = 1.31279451629958
STEP 3: Convert Result to Output's Unit
1.31279451629958 Ampere --> No Conversion Required
FINAL ANSWER
1.31279451629958 1.312795 Ampere <-- Line to Neutral Current
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Team Softusvista
Softusvista Office (Pune), India
Team Softusvista has verified this Calculator and 1100+ more calculators!

AC Circuit Design Calculators

Capacitance for Parallel RLC Circuit using Q Factor
​ LaTeX ​ Go Capacitance = (Inductance*Parallel RLC Quality Factor^2)/Resistance^2
Capacitance for Series RLC Circuit given Q Factor
​ LaTeX ​ Go Capacitance = Inductance/(Series RLC Quality Factor^2*Resistance^2)
Capacitance given Cut off Frequency
​ LaTeX ​ Go Capacitance = 1/(2*Resistance*pi*Cut-off Frequency)
Capacitance using Time Constant
​ LaTeX ​ Go Capacitance = Time Constant/Resistance

Line to Neutral Current using Real Power Formula

​LaTeX ​Go
Line to Neutral Current = Real Power/(3*cos(Phase Difference)*Line to Neutral Voltage)
Iln = P/(3*cos(Φ)*Vln)

What is the difference between real power and reactive power?

Real Power is equal to the Reactive Power i.e. there is no VAr in DC Circuits. Only Real Power exists. There is no Reactive Power in DC circuits due to the zero phase angle (Φ) between current and voltage. Real power is important to produce heat and utilize the electric and magnetic field generated by Reactive Power.

How to Calculate Line to Neutral Current using Real Power?

Line to Neutral Current using Real Power calculator uses Line to Neutral Current = Real Power/(3*cos(Phase Difference)*Line to Neutral Voltage) to calculate the Line to Neutral Current, Line to Neutral Current using Real Power is a current flow between the line to neutral and the real power is the average power in watts delivered to a load. It is the only useful power. It is the actual power dissipated by the load. Line to Neutral Current is denoted by Iln symbol.

How to calculate Line to Neutral Current using Real Power using this online calculator? To use this online calculator for Line to Neutral Current using Real Power, enter Real Power (P), Phase Difference (Φ) & Line to Neutral Voltage (Vln) and hit the calculate button. Here is how the Line to Neutral Current using Real Power calculation can be explained with given input values -> 1.312795 = 235/(3*cos(0.5235987755982)*68.9).

FAQ

What is Line to Neutral Current using Real Power?
Line to Neutral Current using Real Power is a current flow between the line to neutral and the real power is the average power in watts delivered to a load. It is the only useful power. It is the actual power dissipated by the load and is represented as Iln = P/(3*cos(Φ)*Vln) or Line to Neutral Current = Real Power/(3*cos(Phase Difference)*Line to Neutral Voltage). The Real Power P is the average power in watts delivered to a load. It is the only useful power. It is the actual power dissipated by the load, Phase Difference is defined as the difference between the phasor of apparent and real power (in degrees) or between voltage and current in an ac circuit & The Line to Neutral Voltage (usually referred to as phase voltage) is the voltage between any of the 3 phases and the central star point which is connected to the earth.
How to calculate Line to Neutral Current using Real Power?
Line to Neutral Current using Real Power is a current flow between the line to neutral and the real power is the average power in watts delivered to a load. It is the only useful power. It is the actual power dissipated by the load is calculated using Line to Neutral Current = Real Power/(3*cos(Phase Difference)*Line to Neutral Voltage). To calculate Line to Neutral Current using Real Power, you need Real Power (P), Phase Difference (Φ) & Line to Neutral Voltage (Vln). With our tool, you need to enter the respective value for Real Power, Phase Difference & Line to Neutral Voltage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Line to Neutral Current?
In this formula, Line to Neutral Current uses Real Power, Phase Difference & Line to Neutral Voltage. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Line to Neutral Current = Reactive Power/(3*Line to Neutral Voltage*sin(Phase Difference))