Line Losses using Volume of Conductor Material (DC 3-Wire) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Line Losses = (((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Volume of Conductor*(Maximum Voltage Overhead DC)^2))
Ploss = (((P^2)*ρ*(L^2))/(V*(Vm)^2))
This formula uses 6 Variables
Variables Used
Line Losses - (Measured in Watt) - Line Losses is defined as the total losses occurring in an Overhead DC line when in use.
Power Transmitted - (Measured in Watt) - Power Transmitted is defined as the product of current and voltage phasor in a overhead dc line at the receiving end.
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Length of Wire DC - (Measured in Meter) - Length of Wire DC is the total length of the wire from one end to other end.
Volume of Conductor - (Measured in Cubic Meter) - Volume of Conductor is the total volume of the material used to make the conductor of an overhead dc line.
Maximum Voltage Overhead DC - (Measured in Volt) - Maximum Voltage Overhead DC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
STEP 1: Convert Input(s) to Base Unit
Power Transmitted: 920 Watt --> 920 Watt No Conversion Required
Resistivity: 1.7E-05 Ohm Meter --> 1.7E-05 Ohm Meter No Conversion Required
Length of Wire DC: 12.7 Meter --> 12.7 Meter No Conversion Required
Volume of Conductor: 26 Cubic Meter --> 26 Cubic Meter No Conversion Required
Maximum Voltage Overhead DC: 60.26 Volt --> 60.26 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ploss = (((P^2)*ρ*(L^2))/(V*(Vm)^2)) --> (((920^2)*1.7E-05*(12.7^2))/(26*(60.26)^2))
Evaluating ... ...
Ploss = 0.024581049158871
STEP 3: Convert Result to Output's Unit
0.024581049158871 Watt --> No Conversion Required
FINAL ANSWER
0.024581049158871 0.024581 Watt <-- Line Losses
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Wire Parameters Calculators

Volume of Conductor Material (DC 3-Wire)
​ LaTeX ​ Go Volume of Conductor = ((2.5)*2)*(Current Overhead DC^2)*Resistivity*(Length of Wire DC^2)/Line Losses
Length using Line Losses(DC 3-Wire)
​ LaTeX ​ Go Length of Wire DC = Line Losses*Area of Overhead DC Wire/(2*(Current Overhead DC^2)*Resistivity)
Area of X-Section using Line Losses(DC 3-Wire)
​ LaTeX ​ Go Area of Overhead DC Wire = ((Current Overhead DC^2)*Resistivity)*Length of Wire DC/Line Losses
Area of X-Section using Volume of Conductor Material (DC 3-Wire)
​ LaTeX ​ Go Area of Overhead DC Wire = Volume of Conductor/((2.5)*Length of Wire DC)

Line Losses using Volume of Conductor Material (DC 3-Wire) Formula

​LaTeX ​Go
Line Losses = (((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Volume of Conductor*(Maximum Voltage Overhead DC)^2))
Ploss = (((P^2)*ρ*(L^2))/(V*(Vm)^2))

What is a 3 wire dc system?

This is basically a combination of two series-connected unipolar DC systems. It consists of three conductors, two outer conductors (one is positive and the other is negative), and one middle conductor which acts as neutral.

How to Calculate Line Losses using Volume of Conductor Material (DC 3-Wire)?

Line Losses using Volume of Conductor Material (DC 3-Wire) calculator uses Line Losses = (((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Volume of Conductor*(Maximum Voltage Overhead DC)^2)) to calculate the Line Losses, The Line Losses using Volume of Conductor Material (DC 3-wire) formula is defined as a loss of electric energy due to the heating of line wires by the current. Line Losses is denoted by Ploss symbol.

How to calculate Line Losses using Volume of Conductor Material (DC 3-Wire) using this online calculator? To use this online calculator for Line Losses using Volume of Conductor Material (DC 3-Wire), enter Power Transmitted (P), Resistivity (ρ), Length of Wire DC (L), Volume of Conductor (V) & Maximum Voltage Overhead DC (Vm) and hit the calculate button. Here is how the Line Losses using Volume of Conductor Material (DC 3-Wire) calculation can be explained with given input values -> 0.024581 = (((920^2)*1.7E-05*(12.7^2))/(26*(60.26)^2)).

FAQ

What is Line Losses using Volume of Conductor Material (DC 3-Wire)?
The Line Losses using Volume of Conductor Material (DC 3-wire) formula is defined as a loss of electric energy due to the heating of line wires by the current and is represented as Ploss = (((P^2)*ρ*(L^2))/(V*(Vm)^2)) or Line Losses = (((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Volume of Conductor*(Maximum Voltage Overhead DC)^2)). Power Transmitted is defined as the product of current and voltage phasor in a overhead dc line at the receiving end, Resistivity is the measure of how strongly a material opposes the flow of current through them, Length of Wire DC is the total length of the wire from one end to other end, Volume of Conductor is the total volume of the material used to make the conductor of an overhead dc line & Maximum Voltage Overhead DC is defined as the peak amplitude of the AC voltage supplied to the line or wire.
How to calculate Line Losses using Volume of Conductor Material (DC 3-Wire)?
The Line Losses using Volume of Conductor Material (DC 3-wire) formula is defined as a loss of electric energy due to the heating of line wires by the current is calculated using Line Losses = (((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Volume of Conductor*(Maximum Voltage Overhead DC)^2)). To calculate Line Losses using Volume of Conductor Material (DC 3-Wire), you need Power Transmitted (P), Resistivity (ρ), Length of Wire DC (L), Volume of Conductor (V) & Maximum Voltage Overhead DC (Vm). With our tool, you need to enter the respective value for Power Transmitted, Resistivity, Length of Wire DC, Volume of Conductor & Maximum Voltage Overhead DC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Line Losses?
In this formula, Line Losses uses Power Transmitted, Resistivity, Length of Wire DC, Volume of Conductor & Maximum Voltage Overhead DC. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Line Losses = (((Power Transmitted^2)*Resistivity*(Length of Wire DC^2))/(Constant Overhead DC*(Maximum Voltage Overhead DC)^2))
  • Line Losses = ((Power Transmitted^2)*Resistivity*Length of Wire DC/(Area of Overhead DC Wire*(Maximum Voltage Overhead DC^2)))
  • Line Losses = 2*(Current Overhead DC^2)*Resistance Overhead DC