Line Losses using Resistance (DC Two-Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Line Losses = 2*(Power Transmitted^2)*Resistance underground DC/((Maximum Voltage^2))
Pline = 2*(P^2)*R1/((Vm^2))
This formula uses 4 Variables
Variables Used
Line Losses - (Measured in Watt) - Line Losses is defined as the losses that are produced in the line.
Power Transmitted - (Measured in Watt) - Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work.
Resistance underground DC - (Measured in Ohm) - Resistance underground DC is defined as the time rate of flow of charge through a cross-sectional area.
Maximum Voltage - (Measured in Volt) - Maximum Voltage the highest voltage rating for electrical devices.
STEP 1: Convert Input(s) to Base Unit
Power Transmitted: 300 Watt --> 300 Watt No Conversion Required
Resistance underground DC: 5 Ohm --> 5 Ohm No Conversion Required
Maximum Voltage: 60 Volt --> 60 Volt No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pline = 2*(P^2)*R1/((Vm^2)) --> 2*(300^2)*5/((60^2))
Evaluating ... ...
Pline = 250
STEP 3: Convert Result to Output's Unit
250 Watt --> No Conversion Required
FINAL ANSWER
250 Watt <-- Line Losses
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Wire Parameters Calculators

Volume of Conductor Material using Resistance (DC Two-Wire US)
​ LaTeX ​ Go Volume Of Conductor = (4*(Power Transmitted^2)*Resistance underground DC*Area of underground dc wire*Length of Wire DC)/(Line Losses*(Maximum Voltage^2))
Volume of Conductor Material (DC Two-Wire US)
​ LaTeX ​ Go Volume Of Conductor = 4*(Power Transmitted^2)*Resistivity*(Length of Wire DC^2)/(Line Losses*(Maximum Voltage^2))
Volume of Conductor Material using Load Current (DC Two-Wire US)
​ LaTeX ​ Go Volume Of Conductor = 4*Resistivity*(Length of Wire DC^2)*(Current underground DC^2)/Line Losses
Volume of Conductor Material using Area and Length(DC Two-Wire US)
​ LaTeX ​ Go Volume Of Conductor = Area of underground dc wire*Length of Wire DC*2

Line Losses using Resistance (DC Two-Wire US) Formula

​LaTeX ​Go
Line Losses = 2*(Power Transmitted^2)*Resistance underground DC/((Maximum Voltage^2))
Pline = 2*(P^2)*R1/((Vm^2))

What is the volume of conductor material in DC Two-Wire underground system?

The volume of conductor material required in this system is 1 times that of a 2-wire d.c.system with the one conductor earthed.

How to Calculate Line Losses using Resistance (DC Two-Wire US)?

Line Losses using Resistance (DC Two-Wire US) calculator uses Line Losses = 2*(Power Transmitted^2)*Resistance underground DC/((Maximum Voltage^2)) to calculate the Line Losses, The Line Losses using Resistance (DC Two-Wire US) formula is defined as the loss of electric energy due to the heating of line wires by the current. Line Losses is denoted by Pline symbol.

How to calculate Line Losses using Resistance (DC Two-Wire US) using this online calculator? To use this online calculator for Line Losses using Resistance (DC Two-Wire US), enter Power Transmitted (P), Resistance underground DC (R1) & Maximum Voltage (Vm) and hit the calculate button. Here is how the Line Losses using Resistance (DC Two-Wire US) calculation can be explained with given input values -> 250 = 2*(300^2)*5/((60^2)).

FAQ

What is Line Losses using Resistance (DC Two-Wire US)?
The Line Losses using Resistance (DC Two-Wire US) formula is defined as the loss of electric energy due to the heating of line wires by the current and is represented as Pline = 2*(P^2)*R1/((Vm^2)) or Line Losses = 2*(Power Transmitted^2)*Resistance underground DC/((Maximum Voltage^2)). Power Transmitted is the amount of power that is transferred from its place of generation to a location where it is applied to perform useful work, Resistance underground DC is defined as the time rate of flow of charge through a cross-sectional area & Maximum Voltage the highest voltage rating for electrical devices.
How to calculate Line Losses using Resistance (DC Two-Wire US)?
The Line Losses using Resistance (DC Two-Wire US) formula is defined as the loss of electric energy due to the heating of line wires by the current is calculated using Line Losses = 2*(Power Transmitted^2)*Resistance underground DC/((Maximum Voltage^2)). To calculate Line Losses using Resistance (DC Two-Wire US), you need Power Transmitted (P), Resistance underground DC (R1) & Maximum Voltage (Vm). With our tool, you need to enter the respective value for Power Transmitted, Resistance underground DC & Maximum Voltage and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Line Losses?
In this formula, Line Losses uses Power Transmitted, Resistance underground DC & Maximum Voltage. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Line Losses = 2*(Power Transmitted^2)*Resistivity*Length of Wire DC/((Maximum Voltage^2)*Area of underground dc wire)
  • Line Losses = 2*(Current underground DC^2)*Resistivity*Length of Wire DC/(Area of underground dc wire)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!