Line Losses using Load Current (Single Phase Two Wire Mid-Point OS) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Line Losses = 2*Current Overhead AC^2*Resistance Overhead AC
Ploss = 2*I^2*R
This formula uses 3 Variables
Variables Used
Line Losses - (Measured in Watt) - Line Losses is defined as the total losses occurring in an Overhead AC line when in use.
Current Overhead AC - (Measured in Ampere) - Current Overhead AC is defined as the current flowing through the overhead ac supply wire.
Resistance Overhead AC - (Measured in Ohm) - Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it.
STEP 1: Convert Input(s) to Base Unit
Current Overhead AC: 6.9 Ampere --> 6.9 Ampere No Conversion Required
Resistance Overhead AC: 0.0028 Ohm --> 0.0028 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ploss = 2*I^2*R --> 2*6.9^2*0.0028
Evaluating ... ...
Ploss = 0.266616
STEP 3: Convert Result to Output's Unit
0.266616 Watt --> No Conversion Required
FINAL ANSWER
0.266616 Watt <-- Line Losses
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Wire Parameters Calculators

Length of Wire using Area of X-Section(Single Phase Two Wire Mid-Point Earthed OS)
​ LaTeX ​ Go Length of Overhead AC Wire = (Area of Overhead AC Wire*Maximum Voltage Overhead AC^2*Line Losses*cos(Phase Difference)^2)/(Resistivity*Power Transmitted^2)
Line Losses using Area of X-Section(Single Phase Two Wire Mid-Point Earthed OS)
​ LaTeX ​ Go Line Losses = (Length of Overhead AC Wire*Resistivity*Power Transmitted^2)/(Area of Overhead AC Wire*Maximum Voltage Overhead AC^2*cos(Phase Difference)^2)
Area of X-Section(Single Phase Two Wire Mid-Point Earthed)
​ LaTeX ​ Go Area of Overhead AC Wire = (Power Transmitted^2*Resistivity*Length of Overhead AC Wire)/(((cos(Phase Difference))^2)*Line Losses*Voltage Overhead AC^2)
Constant (Single Phase Two Wire Mid-Point Earthed)
​ LaTeX ​ Go Constant Overhead AC = (4*Power Transmitted^2*Resistivity*Length of Overhead AC Wire)/(Line Losses*Voltage Overhead AC^2)

Line Losses using Load Current (Single Phase Two Wire Mid-Point OS) Formula

​LaTeX ​Go
Line Losses = 2*Current Overhead AC^2*Resistance Overhead AC
Ploss = 2*I^2*R

What is the value of maximum voltage and volume of conductor material in this system?

The volume of conductor material required in this system is 1/2cos2θ times that of 2-wire d.c.system with the one conductor earthed. The maximum voltage between conductors is 2vm so that r.m.s. value of voltage between them is √2vm.

How to Calculate Line Losses using Load Current (Single Phase Two Wire Mid-Point OS)?

Line Losses using Load Current (Single Phase Two Wire Mid-Point OS) calculator uses Line Losses = 2*Current Overhead AC^2*Resistance Overhead AC to calculate the Line Losses, The Line Losses using Load Current (single Phase two Wire Mid-Point OS) formula is defined as the loss of electric energy due to the heating of line wires by the current. Line Losses is denoted by Ploss symbol.

How to calculate Line Losses using Load Current (Single Phase Two Wire Mid-Point OS) using this online calculator? To use this online calculator for Line Losses using Load Current (Single Phase Two Wire Mid-Point OS), enter Current Overhead AC (I) & Resistance Overhead AC (R) and hit the calculate button. Here is how the Line Losses using Load Current (Single Phase Two Wire Mid-Point OS) calculation can be explained with given input values -> 0.266616 = 2*6.9^2*0.0028.

FAQ

What is Line Losses using Load Current (Single Phase Two Wire Mid-Point OS)?
The Line Losses using Load Current (single Phase two Wire Mid-Point OS) formula is defined as the loss of electric energy due to the heating of line wires by the current and is represented as Ploss = 2*I^2*R or Line Losses = 2*Current Overhead AC^2*Resistance Overhead AC. Current Overhead AC is defined as the current flowing through the overhead ac supply wire & Resistance Overhead AC is defined as the property of the wire or line that opposes the flow of current through it.
How to calculate Line Losses using Load Current (Single Phase Two Wire Mid-Point OS)?
The Line Losses using Load Current (single Phase two Wire Mid-Point OS) formula is defined as the loss of electric energy due to the heating of line wires by the current is calculated using Line Losses = 2*Current Overhead AC^2*Resistance Overhead AC. To calculate Line Losses using Load Current (Single Phase Two Wire Mid-Point OS), you need Current Overhead AC (I) & Resistance Overhead AC (R). With our tool, you need to enter the respective value for Current Overhead AC & Resistance Overhead AC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Line Losses?
In this formula, Line Losses uses Current Overhead AC & Resistance Overhead AC. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Line Losses = (Length of Overhead AC Wire*Resistivity*Power Transmitted^2)/(Area of Overhead AC Wire*Maximum Voltage Overhead AC^2*cos(Phase Difference)^2)
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!