Line Losses using Load Current (2 Phase 4 Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Line Losses = Current Underground AC^2*2*Resistivity*Length of Underground AC Wire/Area of Underground AC Wire
Ploss = I^2*2*ρ*L/A
This formula uses 5 Variables
Variables Used
Line Losses - (Measured in Watt) - Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Current Underground AC - (Measured in Ampere) - Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Resistivity - (Measured in Ohm Meter) - Resistivity is the measure of how strongly a material opposes the flow of current through them.
Length of Underground AC Wire - (Measured in Meter) - Length of Underground AC Wire is the total length of the wire from one end to other end.
Area of Underground AC Wire - (Measured in Square Meter) - Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
STEP 1: Convert Input(s) to Base Unit
Current Underground AC: 9 Ampere --> 9 Ampere No Conversion Required
Resistivity: 1.7E-05 Ohm Meter --> 1.7E-05 Ohm Meter No Conversion Required
Length of Underground AC Wire: 24 Meter --> 24 Meter No Conversion Required
Area of Underground AC Wire: 1.28 Square Meter --> 1.28 Square Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ploss = I^2*2*ρ*L/A --> 9^2*2*1.7E-05*24/1.28
Evaluating ... ...
Ploss = 0.0516375
STEP 3: Convert Result to Output's Unit
0.0516375 Watt --> No Conversion Required
FINAL ANSWER
0.0516375 0.051638 Watt <-- Line Losses
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Wire Parameters Calculators

Length using Area of X-Section (2 Phase 4 Wire US)
​ LaTeX ​ Go Length of Underground AC Wire = (Area of Underground AC Wire*Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference))^2)/(4*Resistivity*(Power Transmitted^2))
Line Losses using Area of X-Section (2 Phase 4 Wire US)
​ LaTeX ​ Go Line Losses = 4*Resistivity*Length of Underground AC Wire*(Power Transmitted^2)/(Area of Underground AC Wire*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2))
Length using Line Losses (2 Phase 4 Wire US)
​ LaTeX ​ Go Length of Underground AC Wire = Line Losses*Area of Underground AC Wire/(2*(Current Underground AC^2)*Resistivity)
Line Losses (2 Phase 4 Wire US)
​ LaTeX ​ Go Line Losses = 2*(Current Underground AC^2)*Resistance Underground AC

Line Losses using Load Current (2 Phase 4 Wire US) Formula

​LaTeX ​Go
Line Losses = Current Underground AC^2*2*Resistivity*Length of Underground AC Wire/Area of Underground AC Wire
Ploss = I^2*2*ρ*L/A

What is the value of maximum voltage in 2-phase 4-wire underground system?

The maximum voltage between conductors is vm so that r.m.s. value of voltage between them is vm/√2.

How to Calculate Line Losses using Load Current (2 Phase 4 Wire US)?

Line Losses using Load Current (2 Phase 4 Wire US) calculator uses Line Losses = Current Underground AC^2*2*Resistivity*Length of Underground AC Wire/Area of Underground AC Wire to calculate the Line Losses, The Line Losses using Load Current (2 phase 4 wire US) formula is defined as the loss of electric energy due to the heating of line wires by the current. Line Losses is denoted by Ploss symbol.

How to calculate Line Losses using Load Current (2 Phase 4 Wire US) using this online calculator? To use this online calculator for Line Losses using Load Current (2 Phase 4 Wire US), enter Current Underground AC (I), Resistivity (ρ), Length of Underground AC Wire (L) & Area of Underground AC Wire (A) and hit the calculate button. Here is how the Line Losses using Load Current (2 Phase 4 Wire US) calculation can be explained with given input values -> 0.051638 = 9^2*2*1.7E-05*24/1.28.

FAQ

What is Line Losses using Load Current (2 Phase 4 Wire US)?
The Line Losses using Load Current (2 phase 4 wire US) formula is defined as the loss of electric energy due to the heating of line wires by the current and is represented as Ploss = I^2*2*ρ*L/A or Line Losses = Current Underground AC^2*2*Resistivity*Length of Underground AC Wire/Area of Underground AC Wire. Current Underground AC is defined as the current flowing through the overhead ac supply wire, Resistivity is the measure of how strongly a material opposes the flow of current through them, Length of Underground AC Wire is the total length of the wire from one end to other end & Area of Underground AC Wire is defined as the cross-sectional area of the wire of an AC supply system.
How to calculate Line Losses using Load Current (2 Phase 4 Wire US)?
The Line Losses using Load Current (2 phase 4 wire US) formula is defined as the loss of electric energy due to the heating of line wires by the current is calculated using Line Losses = Current Underground AC^2*2*Resistivity*Length of Underground AC Wire/Area of Underground AC Wire. To calculate Line Losses using Load Current (2 Phase 4 Wire US), you need Current Underground AC (I), Resistivity (ρ), Length of Underground AC Wire (L) & Area of Underground AC Wire (A). With our tool, you need to enter the respective value for Current Underground AC, Resistivity, Length of Underground AC Wire & Area of Underground AC Wire and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Line Losses?
In this formula, Line Losses uses Current Underground AC, Resistivity, Length of Underground AC Wire & Area of Underground AC Wire. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Line Losses = 4*Resistivity*Length of Underground AC Wire*(Power Transmitted^2)/(Area of Underground AC Wire*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2))
  • Line Losses = 2*(Current Underground AC^2)*Resistance Underground AC
  • Line Losses = (Current Underground AC*Length of Underground AC Wire)^2*4*Resistivity/Volume Of Conductor