Line Losses (3 Phase 3 Wire US) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Line Losses = 3*(Current Underground AC^2)*Resistance Underground AC
Ploss = 3*(I^2)*R
This formula uses 3 Variables
Variables Used
Line Losses - (Measured in Watt) - Line Losses is defined as the total losses occurring in an Underground AC line when in use.
Current Underground AC - (Measured in Ampere) - Current Underground AC is defined as the current flowing through the overhead ac supply wire.
Resistance Underground AC - (Measured in Ohm) - Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
STEP 1: Convert Input(s) to Base Unit
Current Underground AC: 9 Ampere --> 9 Ampere No Conversion Required
Resistance Underground AC: 5 Ohm --> 5 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ploss = 3*(I^2)*R --> 3*(9^2)*5
Evaluating ... ...
Ploss = 1215
STEP 3: Convert Result to Output's Unit
1215 Watt --> No Conversion Required
FINAL ANSWER
1215 Watt <-- Line Losses
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Wire Parameters Calculators

Volume of Conductor Material (3 Phase 3 Wire US)
​ LaTeX ​ Go Volume Of Conductor = 6*Resistivity*(Power Transmitted^2)*(Length of Underground AC Wire^2)/(Line Losses*(Maximum Voltage Underground AC^2)*(cos(Phase Difference)^2))
Constant using Volume of Conductor Material (3 Phase 3 Wire US)
​ LaTeX ​ Go Constant Underground AC = Volume Of Conductor*(cos(Phase Difference))^2/(1.5)
Area of X Section using Volume of Conductor Material (3 Phase 3 Wire US)
​ LaTeX ​ Go Area of Underground AC Wire = Volume Of Conductor/((3)*Length of Underground AC Wire)
Volume of Conductor Material when Area and Length is Given(3 Phase 3 Wire US)
​ LaTeX ​ Go Volume Of Conductor = 3*Area of Underground AC Wire*Length of Underground AC Wire

Line Losses (3 Phase 3 Wire US) Formula

​LaTeX ​Go
Line Losses = 3*(Current Underground AC^2)*Resistance Underground AC
Ploss = 3*(I^2)*R

What is the average line loss?

System average line losses are in the range of six to ten percent on most. Power Plant Step Up Transformer Step DownDistribution Lines Transmission Lines Residence. 1 “Distribution” is, regrettably, an ambiguous term when discussing electric power.

How to Calculate Line Losses (3 Phase 3 Wire US)?

Line Losses (3 Phase 3 Wire US) calculator uses Line Losses = 3*(Current Underground AC^2)*Resistance Underground AC to calculate the Line Losses, The Line Losses (3 phase 3 wire US) formula is defined as the loss of electric energy due to the heating of line wires by the current. Line Losses is denoted by Ploss symbol.

How to calculate Line Losses (3 Phase 3 Wire US) using this online calculator? To use this online calculator for Line Losses (3 Phase 3 Wire US), enter Current Underground AC (I) & Resistance Underground AC (R) and hit the calculate button. Here is how the Line Losses (3 Phase 3 Wire US) calculation can be explained with given input values -> 1215 = 3*(9^2)*5.

FAQ

What is Line Losses (3 Phase 3 Wire US)?
The Line Losses (3 phase 3 wire US) formula is defined as the loss of electric energy due to the heating of line wires by the current and is represented as Ploss = 3*(I^2)*R or Line Losses = 3*(Current Underground AC^2)*Resistance Underground AC. Current Underground AC is defined as the current flowing through the overhead ac supply wire & Resistance Underground AC is defined as the property of the wire or line that opposes the flow of current through it.
How to calculate Line Losses (3 Phase 3 Wire US)?
The Line Losses (3 phase 3 wire US) formula is defined as the loss of electric energy due to the heating of line wires by the current is calculated using Line Losses = 3*(Current Underground AC^2)*Resistance Underground AC. To calculate Line Losses (3 Phase 3 Wire US), you need Current Underground AC (I) & Resistance Underground AC (R). With our tool, you need to enter the respective value for Current Underground AC & Resistance Underground AC and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Line Losses?
In this formula, Line Losses uses Current Underground AC & Resistance Underground AC. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Line Losses = 6*(Power Transmitted)^2*Resistivity*(Length of Underground AC Wire)^2/((Maximum Voltage Underground AC*cos(Phase Difference))^2*Volume Of Conductor)