Formula Used
Limiting Value of Core Length = (7.5)/(Specific Magnetic Loading*Peripheral Speed of Armature*Turns per Coil*Number of Coils between Adjacent Segments)
Llimit = (7.5)/(Bav*Va*Tc*nc)
This formula uses 5 Variables
Variables Used
Limiting Value of Core Length - (Measured in Meter) - Limiting value of Core length is the emf induced in a conductor should exceed 7.5/TcNc in order that the maximum value at load between adjacent segments limited to 30 V.
Specific Magnetic Loading - (Measured in Tesla) - Specific Magnetic loading is defined as the total flux per unit area over the surface of the armature periphery and is denoted by Bav for any electrical machine.
Peripheral Speed of Armature - (Measured in Meter per Second) - Peripheral speed of armature is the distance travel by the armature per unit time is called as peripheral speed. n = speed in r.p.s.
Turns per Coil - Turns per coil refers to the number of turns or windings of wire in each coil of the machine's winding system.
Number of Coils between Adjacent Segments - Number of coils between adjacent segments ,1 for simplex lap winding and P/2 for a simplex wave winding.
STEP 1: Convert Input(s) to Base Unit
Specific Magnetic Loading: 0.458 Weber per Square Meter --> 0.458 Tesla (Check conversion ​here)
Peripheral Speed of Armature: 0.0445 Meter per Second --> 0.0445 Meter per Second No Conversion Required
Turns per Coil: 204 --> No Conversion Required
Number of Coils between Adjacent Segments: 6 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Llimit = (7.5)/(Bav*Va*Tc*nc) --> (7.5)/(0.458*0.0445*204*6)
Evaluating ... ...
Llimit = 0.300645256876118
STEP 3: Convert Result to Output's Unit
0.300645256876118 Meter --> No Conversion Required
FINAL ANSWER
0.300645256876118 0.300645 Meter <-- Limiting Value of Core Length
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by swapanshil kumar
ramgarh engineering college (REC), ramgarh
swapanshil kumar has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has verified this Calculator and 500+ more calculators!

DC Machines Calculators

Peripheral Speed of Armature using Limiting Value of Core Length
​ LaTeX ​ Go Peripheral Speed of Armature = (7.5)/(Specific Magnetic Loading*Limiting Value of Core Length*Turns per Coil*Number of Coils between Adjacent Segments)
Average Gap Density using Limiting Value of Core Length
​ LaTeX ​ Go Specific Magnetic Loading = (7.5)/(Limiting Value of Core Length*Peripheral Speed of Armature*Turns per Coil*Number of Coils between Adjacent Segments)
Limiting Value of Core Length
​ LaTeX ​ Go Limiting Value of Core Length = (7.5)/(Specific Magnetic Loading*Peripheral Speed of Armature*Turns per Coil*Number of Coils between Adjacent Segments)
Number of Poles using Magnetic Loading
​ LaTeX ​ Go Number of Poles = Magnetic Loading/Flux per Pole

Limiting Value of Core Length Formula

​LaTeX ​Go
Limiting Value of Core Length = (7.5)/(Specific Magnetic Loading*Peripheral Speed of Armature*Turns per Coil*Number of Coils between Adjacent Segments)
Llimit = (7.5)/(Bav*Va*Tc*nc)

What are the factors the value of core length?

The value of core length to pole pitch varies from 0.6 to 2. It depends on the cost, efficiency, power factor, overall design.

What is limiting value of armature diameter?

The diameter of the commutator is chosen as 60 to 80% of armature diameter. The limiting factor is the peripheral speed.

How to Calculate Limiting Value of Core Length?

Limiting Value of Core Length calculator uses Limiting Value of Core Length = (7.5)/(Specific Magnetic Loading*Peripheral Speed of Armature*Turns per Coil*Number of Coils between Adjacent Segments) to calculate the Limiting Value of Core Length, The Limiting value of core length is the approaching or closest value of core length of the machine. It depends on the cost, efficiency, power factor, overall design. Limiting Value of Core Length is denoted by Llimit symbol.

How to calculate Limiting Value of Core Length using this online calculator? To use this online calculator for Limiting Value of Core Length, enter Specific Magnetic Loading (Bav), Peripheral Speed of Armature (Va), Turns per Coil (Tc) & Number of Coils between Adjacent Segments (nc) and hit the calculate button. Here is how the Limiting Value of Core Length calculation can be explained with given input values -> 0.300645 = (7.5)/(0.458*0.0445*204*6).

FAQ

What is Limiting Value of Core Length?
The Limiting value of core length is the approaching or closest value of core length of the machine. It depends on the cost, efficiency, power factor, overall design and is represented as Llimit = (7.5)/(Bav*Va*Tc*nc) or Limiting Value of Core Length = (7.5)/(Specific Magnetic Loading*Peripheral Speed of Armature*Turns per Coil*Number of Coils between Adjacent Segments). Specific Magnetic loading is defined as the total flux per unit area over the surface of the armature periphery and is denoted by Bav for any electrical machine, Peripheral speed of armature is the distance travel by the armature per unit time is called as peripheral speed. n = speed in r.p.s, Turns per coil refers to the number of turns or windings of wire in each coil of the machine's winding system & Number of coils between adjacent segments ,1 for simplex lap winding and P/2 for a simplex wave winding.
How to calculate Limiting Value of Core Length?
The Limiting value of core length is the approaching or closest value of core length of the machine. It depends on the cost, efficiency, power factor, overall design is calculated using Limiting Value of Core Length = (7.5)/(Specific Magnetic Loading*Peripheral Speed of Armature*Turns per Coil*Number of Coils between Adjacent Segments). To calculate Limiting Value of Core Length, you need Specific Magnetic Loading (Bav), Peripheral Speed of Armature (Va), Turns per Coil (Tc) & Number of Coils between Adjacent Segments (nc). With our tool, you need to enter the respective value for Specific Magnetic Loading, Peripheral Speed of Armature, Turns per Coil & Number of Coils between Adjacent Segments and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!