How to Calculate Length using Line Losses (2-Phase 3-Wire US)?
Length using Line Losses (2-Phase 3-Wire US) calculator uses Length of Underground AC Wire = Line Losses*Area of Underground AC Wire*(Maximum Voltage Underground AC*cos(Phase Difference))^2/((2+sqrt(2))*(Power Transmitted^2)*Resistivity) to calculate the Length of Underground AC Wire, The Length using Line Losses (2-Phase 3-Wire US) formula is defined as the total length of the wire that used in the two-phase three-wire system. Length of Underground AC Wire is denoted by L symbol.
How to calculate Length using Line Losses (2-Phase 3-Wire US) using this online calculator? To use this online calculator for Length using Line Losses (2-Phase 3-Wire US), enter Line Losses (Ploss), Area of Underground AC Wire (A), Maximum Voltage Underground AC (Vm), Phase Difference (Φ), Power Transmitted (P) & Resistivity (ρ) and hit the calculate button. Here is how the Length using Line Losses (2-Phase 3-Wire US) calculation can be explained with given input values -> 25957.09 = 2.67*1.28*(230*cos(0.5235987755982))^2/((2+sqrt(2))*(300^2)*1.7E-05).