Length of Spillway given Discharge over Ogee Spillway Solution

STEP 0: Pre-Calculation Summary
Formula Used
Spillways Length = Discharge over Ogee Spillway/(Coefficient of Spillway*Head of Water^(3/2))
LSpillways = Q/(Cs*HWater^(3/2))
This formula uses 4 Variables
Variables Used
Spillways Length - (Measured in Meter) - Spillways Length refers to the distance over which water is channeled or released to prevent overflow or flooding.
Discharge over Ogee Spillway - (Measured in Cubic Meter per Second) - Discharge over Ogee Spillway is the fluid flowing per second through a channel or section of a pipe.
Coefficient of Spillway - Coefficient of spillway can be described as the coefficient factor of a spillway obtained from caliberation.
Head of Water - (Measured in Meter) - Head of Water is defined as the height of water columns.
STEP 1: Convert Input(s) to Base Unit
Discharge over Ogee Spillway: 4 Cubic Meter per Second --> 4 Cubic Meter per Second No Conversion Required
Coefficient of Spillway: 0.5 --> No Conversion Required
Head of Water: 2.3 Meter --> 2.3 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
LSpillways = Q/(Cs*HWater^(3/2)) --> 4/(0.5*2.3^(3/2))
Evaluating ... ...
LSpillways = 2.29349729876796
STEP 3: Convert Result to Output's Unit
2.29349729876796 Meter --> No Conversion Required
FINAL ANSWER
2.29349729876796 2.293497 Meter <-- Spillways Length
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by M Naveen
National Institute of Technology (NIT), Warangal
M Naveen has created this Calculator and 500+ more calculators!
Verifier Image
Verified by Rithik Agrawal
National Institute of Technology Karnataka (NITK), Surathkal
Rithik Agrawal has verified this Calculator and 400+ more calculators!

Ogee Spillway Calculators

Head above Crest given Discharge over Ogee Spillway
​ LaTeX ​ Go Head of Water = (Discharge over Ogee Spillway/(Coefficient of Spillway*Spillways Length))^(2/3)
Coefficient of Spillway given Discharge over Ogee Spillway
​ LaTeX ​ Go Coefficient of Spillway = Discharge over Ogee Spillway/(Spillways Length*Head of Water^(3/2))
Length of Spillway given Discharge over Ogee Spillway
​ LaTeX ​ Go Spillways Length = Discharge over Ogee Spillway/(Coefficient of Spillway*Head of Water^(3/2))
Discharge over Ogee Spillway
​ LaTeX ​ Go Discharge over Ogee Spillway = Coefficient of Spillway*Spillways Length*Head of Water^(3/2)

Length of Spillway given Discharge over Ogee Spillway Formula

​LaTeX ​Go
Spillways Length = Discharge over Ogee Spillway/(Coefficient of Spillway*Head of Water^(3/2))
LSpillways = Q/(Cs*HWater^(3/2))

What is meant by Coefficient of Spillway?

Coefficient of Spillway can be stated as the ratio between the actual flow discharge and theoretical flow discharge.

How to Calculate Length of Spillway given Discharge over Ogee Spillway?

Length of Spillway given Discharge over Ogee Spillway calculator uses Spillways Length = Discharge over Ogee Spillway/(Coefficient of Spillway*Head of Water^(3/2)) to calculate the Spillways Length, The Length of Spillway given Discharge over Ogee Spillway is defined as it applies to the area of reclamation and can be defined as ' distance, measured along an axis. Spillways Length is denoted by LSpillways symbol.

How to calculate Length of Spillway given Discharge over Ogee Spillway using this online calculator? To use this online calculator for Length of Spillway given Discharge over Ogee Spillway, enter Discharge over Ogee Spillway (Q), Coefficient of Spillway (Cs) & Head of Water (HWater) and hit the calculate button. Here is how the Length of Spillway given Discharge over Ogee Spillway calculation can be explained with given input values -> 3.952847 = 4/(0.5*2.3^(3/2)).

FAQ

What is Length of Spillway given Discharge over Ogee Spillway?
The Length of Spillway given Discharge over Ogee Spillway is defined as it applies to the area of reclamation and can be defined as ' distance, measured along an axis and is represented as LSpillways = Q/(Cs*HWater^(3/2)) or Spillways Length = Discharge over Ogee Spillway/(Coefficient of Spillway*Head of Water^(3/2)). Discharge over Ogee Spillway is the fluid flowing per second through a channel or section of a pipe, Coefficient of spillway can be described as the coefficient factor of a spillway obtained from caliberation & Head of Water is defined as the height of water columns.
How to calculate Length of Spillway given Discharge over Ogee Spillway?
The Length of Spillway given Discharge over Ogee Spillway is defined as it applies to the area of reclamation and can be defined as ' distance, measured along an axis is calculated using Spillways Length = Discharge over Ogee Spillway/(Coefficient of Spillway*Head of Water^(3/2)). To calculate Length of Spillway given Discharge over Ogee Spillway, you need Discharge over Ogee Spillway (Q), Coefficient of Spillway (Cs) & Head of Water (HWater). With our tool, you need to enter the respective value for Discharge over Ogee Spillway, Coefficient of Spillway & Head of Water and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!