Length of displacer submerged in liquid Solution

STEP 0: Pre-Calculation Summary
Formula Used
Displacer Length = (4*Buoyancy Force)/(Fluid Specific Weight*pi*Pipe Diameter Level^2)
L = (4*Fb)/(γ*pi*D^2)
This formula uses 1 Constants, 4 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Variables Used
Displacer Length - (Measured in Meter) - Displacer Length is the distance from one end to the other, typically measured in units such as meters or inches, indicating its size or extent.
Buoyancy Force - (Measured in Newton) - Buoyancy Force is an upward force exerted by a fluid that opposes the weight of a partially or fully immersed object.
Fluid Specific Weight - (Measured in Newton per Cubic Meter) - Fluid Specific Weight is the ratio of a body’s weight to its volume.
Pipe Diameter Level - (Measured in Meter) - Pipe Diameter Level is the length of the longest chord of the pipe in which the liquid is flowing.
STEP 1: Convert Input(s) to Base Unit
Buoyancy Force: 10.75 Newton --> 10.75 Newton No Conversion Required
Fluid Specific Weight: 800 Newton per Cubic Meter --> 800 Newton per Cubic Meter No Conversion Required
Pipe Diameter Level: 0.07 Meter --> 0.07 Meter No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
L = (4*Fb)/(γ*pi*D^2) --> (4*10.75)/(800*pi*0.07^2)
Evaluating ... ...
L = 3.4916645678324
STEP 3: Convert Result to Output's Unit
3.4916645678324 Meter --> No Conversion Required
FINAL ANSWER
3.4916645678324 3.491665 Meter <-- Displacer Length
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Shobhit Dimri
Bipin Tripathi Kumaon Institute of Technology (BTKIT), Dwarahat
Shobhit Dimri has created this Calculator and 900+ more calculators!
Verifier Image
Verified by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has verified this Calculator and 1900+ more calculators!

Level Measurement Calculators

Cross-Sectional Area of Object
​ LaTeX ​ Go Cross Section Area Level = Buoyancy Force/(Immersed Depth*Fluid Specific Weight)
Immersed Depth
​ LaTeX ​ Go Immersed Depth = Buoyancy Force/(Cross Section Area Level*Fluid Specific Weight)
Buoyancy
​ LaTeX ​ Go Buoyancy Force = Immersed Depth*Cross Section Area Level*Fluid Specific Weight
Depth of Fluid
​ LaTeX ​ Go Depth = Pressure Change/Fluid Specific Weight

Length of displacer submerged in liquid Formula

​LaTeX ​Go
Displacer Length = (4*Buoyancy Force)/(Fluid Specific Weight*pi*Pipe Diameter Level^2)
L = (4*Fb)/(γ*pi*D^2)

What is DP type level transmitter?

Differential Pressure (DP) Level Measurement uses pressure readings and specific gravity to output level. DP Level is a common measurement technique that is used in a wide variety of applications.

How to Calculate Length of displacer submerged in liquid?

Length of displacer submerged in liquid calculator uses Displacer Length = (4*Buoyancy Force)/(Fluid Specific Weight*pi*Pipe Diameter Level^2) to calculate the Displacer Length, The Length of displacer submerged in liquid formula is defined as Displacer level switches are sensors with electrical contact output at specific liquid level. Displacer Length is denoted by L symbol.

How to calculate Length of displacer submerged in liquid using this online calculator? To use this online calculator for Length of displacer submerged in liquid, enter Buoyancy Force (Fb), Fluid Specific Weight (γ) & Pipe Diameter Level (D) and hit the calculate button. Here is how the Length of displacer submerged in liquid calculation can be explained with given input values -> 3.491665 = (4*10.75)/(800*pi*0.07^2).

FAQ

What is Length of displacer submerged in liquid?
The Length of displacer submerged in liquid formula is defined as Displacer level switches are sensors with electrical contact output at specific liquid level and is represented as L = (4*Fb)/(γ*pi*D^2) or Displacer Length = (4*Buoyancy Force)/(Fluid Specific Weight*pi*Pipe Diameter Level^2). Buoyancy Force is an upward force exerted by a fluid that opposes the weight of a partially or fully immersed object, Fluid Specific Weight is the ratio of a body’s weight to its volume & Pipe Diameter Level is the length of the longest chord of the pipe in which the liquid is flowing.
How to calculate Length of displacer submerged in liquid?
The Length of displacer submerged in liquid formula is defined as Displacer level switches are sensors with electrical contact output at specific liquid level is calculated using Displacer Length = (4*Buoyancy Force)/(Fluid Specific Weight*pi*Pipe Diameter Level^2). To calculate Length of displacer submerged in liquid, you need Buoyancy Force (Fb), Fluid Specific Weight (γ) & Pipe Diameter Level (D). With our tool, you need to enter the respective value for Buoyancy Force, Fluid Specific Weight & Pipe Diameter Level and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know