K-Value of Component using Modified Raoult's Law Solution

STEP 0: Pre-Calculation Summary
Formula Used
K value = (Activity Coefficient in Raoults Law*Saturated Pressure in Raoults Law)/Total Pressure of Gas
K = (γRaoults*PSaturated)/PT
This formula uses 4 Variables
Variables Used
K value - K value is defined as the ratio of vapor-phase mole fraction to the liquid phase mole fraction.
Activity Coefficient in Raoults Law - Activity Coefficient in Raoults Law is a factor used in thermodynamics to account for deviations from ideal behaviour in a mixture of chemical substances.
Saturated Pressure in Raoults Law - (Measured in Pascal) - Saturated Pressure in Raoults Law is the pressure at which a given liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given temperature.
Total Pressure of Gas - (Measured in Pascal) - Total pressure of Gas is the sum of all the forces that the gas molecules exert on the walls of their container.
STEP 1: Convert Input(s) to Base Unit
Activity Coefficient in Raoults Law: 0.9 --> No Conversion Required
Saturated Pressure in Raoults Law: 200 Pascal --> 200 Pascal No Conversion Required
Total Pressure of Gas: 102100 Pascal --> 102100 Pascal No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
K = (γRaoults*PSaturated)/PT --> (0.9*200)/102100
Evaluating ... ...
K = 0.00176297747306562
STEP 3: Convert Result to Output's Unit
0.00176297747306562 --> No Conversion Required
FINAL ANSWER
0.00176297747306562 0.001763 <-- K value
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Shivam Sinha
National Institute Of Technology (NIT), Surathkal
Shivam Sinha has created this Calculator and 300+ more calculators!
Verifier Image
Verified by Pragati Jaju
College Of Engineering (COEP), Pune
Pragati Jaju has verified this Calculator and 300+ more calculators!

K values for Gamma Phi formulation, Raoult’s Law, Modified Raoult’s Law, and Henry’s Law Calculators

Fugacity Coefficient of Component using K-Value Expression for Gamma-Phi Formulation
​ LaTeX ​ Go Fugacity Coefficient in Raoults Law = (Activity Coefficient in Raoults Law*Saturated Pressure in Gamma-Phi Formulation)/(K value*Total Pressure of Gas)
K-Value of Component using Gamma-Phi Formulation
​ LaTeX ​ Go K value = (Activity Coefficient in Raoults Law*Saturated Pressure in Gamma-Phi Formulation)/(Fugacity Coefficient in Raoults Law*Total Pressure of Gas)
Activity Coefficient of Component using K-Value Expression for Gamma-Phi Formulation
​ LaTeX ​ Go Activity Coefficient in Raoults Law = (K value*Fugacity Coefficient in Raoults Law*Total Pressure of Gas)/Saturated Pressure in Gamma-Phi Formulation
K-Value or Vapour-Liquid Distribution Ratio of Component
​ LaTeX ​ Go K value = Mole Fraction of Component in Vapor Phase/Mole Fraction of Component in Liquid Phase

K-Value of Component using Modified Raoult's Law Formula

​LaTeX ​Go
K value = (Activity Coefficient in Raoults Law*Saturated Pressure in Raoults Law)/Total Pressure of Gas
K = (γRaoults*PSaturated)/PT

Define K-Value and it's Relation with Relative Volatility (α).

The K value or vapour-liquid distribution ratio of a component is the ratio of vapour mole fraction of that component to the liquid mole fraction of that component. A K value for a more volatile component is larger than a K value for a less volatile component. That means that α (relative volatility) ≥ 1 since the larger K value of the more volatile component is in the numerator and the smaller K of the less volatile component is in the denominator.

What are the Limitations of Henry Law?

Henry law is only applicable when the molecules of the system are in a state of equilibrium. The second limitation is that it does not hold true when gases are placed under extremely high pressure. The third limitation that it is not applicable when the gas and the solution participate in chemical reactions with each other.

How to Calculate K-Value of Component using Modified Raoult's Law?

K-Value of Component using Modified Raoult's Law calculator uses K value = (Activity Coefficient in Raoults Law*Saturated Pressure in Raoults Law)/Total Pressure of Gas to calculate the K value, The K-Value of Component using Modified Raoult's Law formula is defined as the ratio of the product of activity coefficient of that component and saturated pressure of that component to the pressure. K value is denoted by K symbol.

How to calculate K-Value of Component using Modified Raoult's Law using this online calculator? To use this online calculator for K-Value of Component using Modified Raoult's Law, enter Activity Coefficient in Raoults Law Raoults), Saturated Pressure in Raoults Law (PSaturated) & Total Pressure of Gas (PT) and hit the calculate button. Here is how the K-Value of Component using Modified Raoult's Law calculation can be explained with given input values -> 0.000597 = (0.9*200)/102100.

FAQ

What is K-Value of Component using Modified Raoult's Law?
The K-Value of Component using Modified Raoult's Law formula is defined as the ratio of the product of activity coefficient of that component and saturated pressure of that component to the pressure and is represented as K = (γRaoults*PSaturated)/PT or K value = (Activity Coefficient in Raoults Law*Saturated Pressure in Raoults Law)/Total Pressure of Gas. Activity Coefficient in Raoults Law is a factor used in thermodynamics to account for deviations from ideal behaviour in a mixture of chemical substances, Saturated Pressure in Raoults Law is the pressure at which a given liquid and its vapour or a given solid and its vapour can co-exist in equilibrium, at a given temperature & Total pressure of Gas is the sum of all the forces that the gas molecules exert on the walls of their container.
How to calculate K-Value of Component using Modified Raoult's Law?
The K-Value of Component using Modified Raoult's Law formula is defined as the ratio of the product of activity coefficient of that component and saturated pressure of that component to the pressure is calculated using K value = (Activity Coefficient in Raoults Law*Saturated Pressure in Raoults Law)/Total Pressure of Gas. To calculate K-Value of Component using Modified Raoult's Law, you need Activity Coefficient in Raoults Law Raoults), Saturated Pressure in Raoults Law (PSaturated) & Total Pressure of Gas (PT). With our tool, you need to enter the respective value for Activity Coefficient in Raoults Law, Saturated Pressure in Raoults Law & Total Pressure of Gas and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate K value?
In this formula, K value uses Activity Coefficient in Raoults Law, Saturated Pressure in Raoults Law & Total Pressure of Gas. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • K value = Mole Fraction of Component in Vapor Phase/Mole Fraction of Component in Liquid Phase
  • K value = (Activity Coefficient in Raoults Law*Saturated Pressure in Gamma-Phi Formulation)/(Fugacity Coefficient in Raoults Law*Total Pressure of Gas)
  • K value = Saturated Pressure in Raoults Law/Total Pressure of Gas
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!