Junction Depth after Full Scaling VLSI Solution

STEP 0: Pre-Calculation Summary
Formula Used
Junction Depth after Full Scaling = Junction Depth/Scaling Factor
xj' = xj/Sf
This formula uses 3 Variables
Variables Used
Junction Depth after Full Scaling - (Measured in Meter) - Junction Depth after Full Scaling is defined as the distance from the surface to the point where a change in the concentration of dopant atoms occurs after full scaling.
Junction Depth - (Measured in Meter) - Junction Depth is defined as the distance from the surface of a semiconductor material to the point where a significant change in the concentration of dopant atoms occurs.
Scaling Factor - Scaling factor is defined as the ratio by which the dimensions of the transistor are changed during the design process.
STEP 1: Convert Input(s) to Base Unit
Junction Depth: 2 Micrometer --> 2E-06 Meter (Check conversion ​here)
Scaling Factor: 1.5 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
xj' = xj/Sf --> 2E-06/1.5
Evaluating ... ...
xj' = 1.33333333333333E-06
STEP 3: Convert Result to Output's Unit
1.33333333333333E-06 Meter -->1.33333333333333 Micrometer (Check conversion ​here)
FINAL ANSWER
1.33333333333333 1.333333 Micrometer <-- Junction Depth after Full Scaling
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Priyanka Patel
Lalbhai Dalpatbhai College of engineering (LDCE), Ahmedabad
Priyanka Patel has created this Calculator and 25+ more calculators!
Verifier Image
Verified by Santhosh Yadav
Dayananda Sagar College Of Engineering (DSCE), Banglore
Santhosh Yadav has verified this Calculator and 50+ more calculators!

VLSI Material Optimization Calculators

Body Effect Coefficient
​ LaTeX ​ Go Body Effect Coefficient = modulus((Threshold Voltage-Threshold Voltage DIBL)/(sqrt(Surface Potential+(Source Body Potential Difference))-sqrt(Surface Potential)))
DIBL Coefficient
​ LaTeX ​ Go DIBL Coefficient = (Threshold Voltage DIBL-Threshold Voltage)/Drain to Source Potential
Channel Charge
​ LaTeX ​ Go Channel Charge = Gate Capacitance*(Gate to Channel Voltage-Threshold Voltage)
Critical Voltage
​ LaTeX ​ Go Critical Voltage = Critical Electric Field*Electric Field Across Channel Length

Junction Depth after Full Scaling VLSI Formula

​LaTeX ​Go
Junction Depth after Full Scaling = Junction Depth/Scaling Factor
xj' = xj/Sf

What fabrication techniques are commonly used to control junction depth after full scaling?

Techniques such as ion implantation and other doping methods are employed to control and precisely define junction depth after full scaling in semiconductor manufacturing.

How to Calculate Junction Depth after Full Scaling VLSI?

Junction Depth after Full Scaling VLSI calculator uses Junction Depth after Full Scaling = Junction Depth/Scaling Factor to calculate the Junction Depth after Full Scaling, The Junction Depth after Full Scaling VLSI formula is defined as the distance from the surface to the point where a change in the concentration of dopant atoms occurs after full scaling. Junction Depth after Full Scaling is denoted by xj' symbol.

How to calculate Junction Depth after Full Scaling VLSI using this online calculator? To use this online calculator for Junction Depth after Full Scaling VLSI, enter Junction Depth (xj) & Scaling Factor (Sf) and hit the calculate button. Here is how the Junction Depth after Full Scaling VLSI calculation can be explained with given input values -> 1.3E+6 = 2E-06/1.5.

FAQ

What is Junction Depth after Full Scaling VLSI?
The Junction Depth after Full Scaling VLSI formula is defined as the distance from the surface to the point where a change in the concentration of dopant atoms occurs after full scaling and is represented as xj' = xj/Sf or Junction Depth after Full Scaling = Junction Depth/Scaling Factor. Junction Depth is defined as the distance from the surface of a semiconductor material to the point where a significant change in the concentration of dopant atoms occurs & Scaling factor is defined as the ratio by which the dimensions of the transistor are changed during the design process.
How to calculate Junction Depth after Full Scaling VLSI?
The Junction Depth after Full Scaling VLSI formula is defined as the distance from the surface to the point where a change in the concentration of dopant atoms occurs after full scaling is calculated using Junction Depth after Full Scaling = Junction Depth/Scaling Factor. To calculate Junction Depth after Full Scaling VLSI, you need Junction Depth (xj) & Scaling Factor (Sf). With our tool, you need to enter the respective value for Junction Depth & Scaling Factor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!