Intensity of Fluorescence given Degree of Exciplex Formation Solution

STEP 0: Pre-Calculation Summary
Formula Used
Fluorosence Intensity given Degree of Exciplex = Rate Constant of Fluoroscence*Equilibrium Constant for Coordinate Complexes*(1-Degree of Exciplex Formation)/(Rate Constant of Fluoroscence+Rate Constant of Non Radiative Reaction)
Ifgiven_α = Kf*Keq*(1-α)/(Kf+KNR)
This formula uses 5 Variables
Variables Used
Fluorosence Intensity given Degree of Exciplex - (Measured in Watt per Square Meter) - Fluorosence Intensity given Degree of Exciplex is the power transferred per unit area, where the area is measured on the plane perpendicular to the direction of propagation of the energy.
Rate Constant of Fluoroscence - (Measured in Hertz) - Rate Constant of Fluoroscence is the rate at which spontaneous emission occurs.
Equilibrium Constant for Coordinate Complexes - (Measured in Mole per Cubic Meter Second) - Equilibrium Constant for Coordinate Complexes is a stability constant (also called formation constant or binding constant) for the formation of a complex in solution.
Degree of Exciplex Formation - Degree of Exciplex Formation is the fraction of intermediates in photoreactions that lead to unique products.
Rate Constant of Non Radiative Reaction - (Measured in Hertz) - Rate Constant of Non Radiative Reaction is defined as the rate at which deactivation occurs in the form of heat energy.
STEP 1: Convert Input(s) to Base Unit
Rate Constant of Fluoroscence: 750 Revolution per Second --> 750 Hertz (Check conversion ​here)
Equilibrium Constant for Coordinate Complexes: 0.009 Mole per Liter Second --> 9 Mole per Cubic Meter Second (Check conversion ​here)
Degree of Exciplex Formation: 0.9 --> No Conversion Required
Rate Constant of Non Radiative Reaction: 35 Revolution per Second --> 35 Hertz (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Ifgiven_α = Kf*Keq*(1-α)/(Kf+KNR) --> 750*9*(1-0.9)/(750+35)
Evaluating ... ...
Ifgiven_α = 0.859872611464968
STEP 3: Convert Result to Output's Unit
0.859872611464968 Watt per Square Meter --> No Conversion Required
FINAL ANSWER
0.859872611464968 0.859873 Watt per Square Meter <-- Fluorosence Intensity given Degree of Exciplex
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Torsha_Paul
University of Calcutta (CU), Kolkata
Torsha_Paul has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Soupayan banerjee
National University of Judicial Science (NUJS), Kolkata
Soupayan banerjee has verified this Calculator and 900+ more calculators!

Emission Spectroscopy Calculators

Degree of Exciplex Formation
​ LaTeX ​ Go Degree of Exciplex Formation = (Equilibrium Constant for Coordinate Complexes*Quencher Concentration given Degree of Exciplex)/(1+(Equilibrium Constant for Coordinate Complexes*Quencher Concentration given Degree of Exciplex))
Collisional Energy Transfer
​ LaTeX ​ Go Rate of Collisional Energy Transfer = Quenching Constant*Quencher Concentration given Degree of Exciplex*Singlet State Concentration
Difference in Acidity between Ground and Excited State
​ LaTeX ​ Go Difference in pka = pKa of Excited State-pKa of Ground State
Equilibrium Constant for Exciplex Formation
​ LaTeX ​ Go Equilibrium Constant for Coordinate Complexes = 1/(1-Degree of Exciplex Formation)-1

Fluoroscence and Phosphorescence Calculators

Initial Intensity given Degree of Exciplex Formation
​ LaTeX ​ Go Initial Intensity given Degree of Exciplex = Rate Constant of Fluoroscence*Equilibrium Constant for Coordinate Complexes/(Rate Constant of Fluoroscence+Rate Constant of Non Radiative Reaction)
Fluoroscence Intensity without Quenching
​ LaTeX ​ Go Intensity Without Quenching = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Non Radiative Reaction+Rate Constant of Fluoroscence)
Fluoroscence Intensity
​ LaTeX ​ Go Fluorosence Intensity = (Rate Constant of Fluoroscence*Absorption Intensity)/(Rate Constant of Fluoroscence+Rate Constant of Non Radiative Reaction)
Fluorescence Rate Constant
​ LaTeX ​ Go Rate Constant of Fluoroscence = Rate of Fluoroscence/Singlet State Concentration

Intensity of Fluorescence given Degree of Exciplex Formation Formula

​LaTeX ​Go
Fluorosence Intensity given Degree of Exciplex = Rate Constant of Fluoroscence*Equilibrium Constant for Coordinate Complexes*(1-Degree of Exciplex Formation)/(Rate Constant of Fluoroscence+Rate Constant of Non Radiative Reaction)
Ifgiven_α = Kf*Keq*(1-α)/(Kf+KNR)

Why does fluorescence intensity increase?

In addition, the fluorescence intensity depends directly on concentration of fluorophore in the sensing volume, molecular extinction coefficient, and the quantum yield. The collection optics will direct light of selected spectral range to the detector and provide a measurement of emission intensity over the selected range of wavelengths. As a start, we define a simplified mathematical model of the detector output assuming that the detector is a photomultiplier tube (PMT).

How to Calculate Intensity of Fluorescence given Degree of Exciplex Formation?

Intensity of Fluorescence given Degree of Exciplex Formation calculator uses Fluorosence Intensity given Degree of Exciplex = Rate Constant of Fluoroscence*Equilibrium Constant for Coordinate Complexes*(1-Degree of Exciplex Formation)/(Rate Constant of Fluoroscence+Rate Constant of Non Radiative Reaction) to calculate the Fluorosence Intensity given Degree of Exciplex, The Intensity of Fluorescence given Degree of Exciplex Formation formula is defined as important parameter that can be used to measure the concentration of a target in a fluorescence detection method. Fluorescence is based on photoluminescence, a process of glow and light emission. It is a physical process in which light is emitted after it has been absorbed by a substance. The fluorescence intensity indicates how much light (photons) is emitted. Fluorosence Intensity given Degree of Exciplex is denoted by Ifgiven_α symbol.

How to calculate Intensity of Fluorescence given Degree of Exciplex Formation using this online calculator? To use this online calculator for Intensity of Fluorescence given Degree of Exciplex Formation, enter Rate Constant of Fluoroscence (Kf), Equilibrium Constant for Coordinate Complexes (Keq), Degree of Exciplex Formation (α) & Rate Constant of Non Radiative Reaction (KNR) and hit the calculate button. Here is how the Intensity of Fluorescence given Degree of Exciplex Formation calculation can be explained with given input values -> 0.859873 = 750*9*(1-0.9)/(750+35).

FAQ

What is Intensity of Fluorescence given Degree of Exciplex Formation?
The Intensity of Fluorescence given Degree of Exciplex Formation formula is defined as important parameter that can be used to measure the concentration of a target in a fluorescence detection method. Fluorescence is based on photoluminescence, a process of glow and light emission. It is a physical process in which light is emitted after it has been absorbed by a substance. The fluorescence intensity indicates how much light (photons) is emitted and is represented as Ifgiven_α = Kf*Keq*(1-α)/(Kf+KNR) or Fluorosence Intensity given Degree of Exciplex = Rate Constant of Fluoroscence*Equilibrium Constant for Coordinate Complexes*(1-Degree of Exciplex Formation)/(Rate Constant of Fluoroscence+Rate Constant of Non Radiative Reaction). Rate Constant of Fluoroscence is the rate at which spontaneous emission occurs, Equilibrium Constant for Coordinate Complexes is a stability constant (also called formation constant or binding constant) for the formation of a complex in solution, Degree of Exciplex Formation is the fraction of intermediates in photoreactions that lead to unique products & Rate Constant of Non Radiative Reaction is defined as the rate at which deactivation occurs in the form of heat energy.
How to calculate Intensity of Fluorescence given Degree of Exciplex Formation?
The Intensity of Fluorescence given Degree of Exciplex Formation formula is defined as important parameter that can be used to measure the concentration of a target in a fluorescence detection method. Fluorescence is based on photoluminescence, a process of glow and light emission. It is a physical process in which light is emitted after it has been absorbed by a substance. The fluorescence intensity indicates how much light (photons) is emitted is calculated using Fluorosence Intensity given Degree of Exciplex = Rate Constant of Fluoroscence*Equilibrium Constant for Coordinate Complexes*(1-Degree of Exciplex Formation)/(Rate Constant of Fluoroscence+Rate Constant of Non Radiative Reaction). To calculate Intensity of Fluorescence given Degree of Exciplex Formation, you need Rate Constant of Fluoroscence (Kf), Equilibrium Constant for Coordinate Complexes (Keq), Degree of Exciplex Formation (α) & Rate Constant of Non Radiative Reaction (KNR). With our tool, you need to enter the respective value for Rate Constant of Fluoroscence, Equilibrium Constant for Coordinate Complexes, Degree of Exciplex Formation & Rate Constant of Non Radiative Reaction and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!