Input Power of Single Phase Full Converter Drives Solution

STEP 0: Pre-Calculation Summary
Formula Used
Input Power = ((2*sqrt(2))/pi)*cos(Delay Angle of Thyristor)
Pin = ((2*sqrt(2))/pi)*cos(α)
This formula uses 1 Constants, 2 Functions, 2 Variables
Constants Used
pi - Archimedes' constant Value Taken As 3.14159265358979323846264338327950288
Functions Used
cos - Cosine of an angle is the ratio of the side adjacent to the angle to the hypotenuse of the triangle., cos(Angle)
sqrt - A square root function is a function that takes a non-negative number as an input and returns the square root of the given input number., sqrt(Number)
Variables Used
Input Power - (Measured in Watt) - Input Power of single-phase full converter drive is an electronic control system used to regulate the speed and direction of single-phase alternating current (AC) motors.
Delay Angle of Thyristor - (Measured in Radian) - Delay Angle of Thyristor is the angle at which thyristors are triggered after zero crossing.
STEP 1: Convert Input(s) to Base Unit
Delay Angle of Thyristor: 70 Degree --> 1.2217304763958 Radian (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Pin = ((2*sqrt(2))/pi)*cos(α) --> ((2*sqrt(2))/pi)*cos(1.2217304763958)
Evaluating ... ...
Pin = 0.307926315490687
STEP 3: Convert Result to Output's Unit
0.307926315490687 Watt --> No Conversion Required
FINAL ANSWER
0.307926315490687 0.307926 Watt <-- Input Power
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Mohamed Fazil V
Acharya institute of technology (AIT), Bengaluru
Mohamed Fazil V has created this Calculator and 50+ more calculators!
Verifier Image
Verified by Parminder Singh
Chandigarh University (CU), Punjab
Parminder Singh has verified this Calculator and 500+ more calculators!

Single Phase Drives Calculators

Average Armature Voltage of Single Phase Half-Wave Converter Drive
​ LaTeX ​ Go Half Drive Armature Voltage = Peak Input Voltage/(2*pi)*(1+cos(Delay Angle of Thyristor))
RMS Value of Thyristor Current in Half Wave Converter Drives
​ LaTeX ​ Go RMS of Source Current = Armature Current*((pi-Delay Angle of Thyristor)/(2*pi))^(1/2)
Average Armature Voltage of Single Phase Full-Converter Drives
​ LaTeX ​ Go Full Drive Armature Voltage = (2*Peak Input Voltage*cos(Delay Angle of Thyristor))/pi
Average Field Voltage of Single Phase Semi-Converter Drives
​ LaTeX ​ Go Semi Drive Field Voltage = (Peak Input Voltage/pi)*(1+cos(Delay Angle of Thyristor))

Input Power of Single Phase Full Converter Drives Formula

​LaTeX ​Go
Input Power = ((2*sqrt(2))/pi)*cos(Delay Angle of Thyristor)
Pin = ((2*sqrt(2))/pi)*cos(α)

What is Input Supply of Single Phase Full Converter Drives ?

The input supply of a single-phase full converter drive refers to the electrical power source that provides energy to the drive system. A single-phase full converter drive is an electronic control system used to regulate the speed and direction of single-phase alternating current (AC) motors.

How to Calculate Input Power of Single Phase Full Converter Drives?

Input Power of Single Phase Full Converter Drives calculator uses Input Power = ((2*sqrt(2))/pi)*cos(Delay Angle of Thyristor) to calculate the Input Power, Input Power of Single Phase Full Converter Drives is an electronic control system used to regulate the speed and direction of single-phase alternating current (AC) motors. It typically consists of a power electronic converter that converts AC power to direct current (DC), and then an inverter that converts the DC back to AC with variable voltage and frequency, allowing for precise control of the motor. Input Power is denoted by Pin symbol.

How to calculate Input Power of Single Phase Full Converter Drives using this online calculator? To use this online calculator for Input Power of Single Phase Full Converter Drives, enter Delay Angle of Thyristor (α) and hit the calculate button. Here is how the Input Power of Single Phase Full Converter Drives calculation can be explained with given input values -> 0.307926 = ((2*sqrt(2))/pi)*cos(1.2217304763958).

FAQ

What is Input Power of Single Phase Full Converter Drives?
Input Power of Single Phase Full Converter Drives is an electronic control system used to regulate the speed and direction of single-phase alternating current (AC) motors. It typically consists of a power electronic converter that converts AC power to direct current (DC), and then an inverter that converts the DC back to AC with variable voltage and frequency, allowing for precise control of the motor and is represented as Pin = ((2*sqrt(2))/pi)*cos(α) or Input Power = ((2*sqrt(2))/pi)*cos(Delay Angle of Thyristor). Delay Angle of Thyristor is the angle at which thyristors are triggered after zero crossing.
How to calculate Input Power of Single Phase Full Converter Drives?
Input Power of Single Phase Full Converter Drives is an electronic control system used to regulate the speed and direction of single-phase alternating current (AC) motors. It typically consists of a power electronic converter that converts AC power to direct current (DC), and then an inverter that converts the DC back to AC with variable voltage and frequency, allowing for precise control of the motor is calculated using Input Power = ((2*sqrt(2))/pi)*cos(Delay Angle of Thyristor). To calculate Input Power of Single Phase Full Converter Drives, you need Delay Angle of Thyristor (α). With our tool, you need to enter the respective value for Delay Angle of Thyristor and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!