Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow Solution

STEP 0: Pre-Calculation Summary
Formula Used
Initial Reactant Concentration in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Reactant Conversion in Mixed Flow
Co = (kmixed flow*𝛕mixed)/Xmfr
This formula uses 4 Variables
Variables Used
Initial Reactant Concentration in Mixed Flow - (Measured in Mole per Cubic Meter) - The Initial Reactant Concentration in Mixed Flow refers to the amount of reactant present in the solvent before the considered process.
Rate Constant for Zero Order in Mixed Flow - (Measured in Mole per Cubic Meter Second) - The Rate Constant for Zero Order in Mixed Flow is equal to the rate of the reaction as the rate of reaction is proportional to zero power of the concentration of the reactant.
Space Time in Mixed Flow - (Measured in Second) - Space Time in Mixed Flow is the time necessary to process volume of reactor fluid at the entrance conditions.
Reactant Conversion in Mixed Flow - Reactant Conversion in Mixed Flow gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1.
STEP 1: Convert Input(s) to Base Unit
Rate Constant for Zero Order in Mixed Flow: 1125 Mole per Cubic Meter Second --> 1125 Mole per Cubic Meter Second No Conversion Required
Space Time in Mixed Flow: 0.05 Second --> 0.05 Second No Conversion Required
Reactant Conversion in Mixed Flow: 0.71 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Co = (kmixed flow*𝛕mixed)/Xmfr --> (1125*0.05)/0.71
Evaluating ... ...
Co = 79.2253521126761
STEP 3: Convert Result to Output's Unit
79.2253521126761 Mole per Cubic Meter --> No Conversion Required
FINAL ANSWER
79.2253521126761 79.22535 Mole per Cubic Meter <-- Initial Reactant Concentration in Mixed Flow
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by akhilesh
K. K. Wagh Institute of Engineering Education and Research (K.K.W.I.E.E.R.), Nashik
akhilesh has created this Calculator and 200+ more calculators!
Verifier Image
Verified by Prerana Bakli
University of Hawaiʻi at Mānoa (UH Manoa), Hawaii, USA
Prerana Bakli has verified this Calculator and 1600+ more calculators!

Mixed Flow Calculators

Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Reactant Concentration at given Time = Initial Reactant Concentration in Mixed Flow-(Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)
Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Initial Reactant Concentration in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Reactant Conversion in Mixed Flow
Reactant Conversion for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Reactant Conversion in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Initial Reactant Concentration in Mixed Flow
Rate Constant for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Rate Constant for Zero Order in Mixed Flow = (Reactant Conversion in Mixed Flow*Initial Reactant Concentration in Mixed Flow)/Space Time in Mixed Flow

Reactor Performance Equations for Constant Volume Reactions Calculators

Initial Reactant Concentration for Second Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Initial Reactant Concentration in Mixed Flow = (Reactant Conversion in Mixed Flow)/((1-Reactant Conversion in Mixed Flow)^2*(Space Time in Mixed Flow)*(Rate Constant for Second Order in Mixed Flow))
Rate Constant for First Order Reaction using Reactant Concentration for Mixed Flow
​ LaTeX ​ Go Rate Constant for First Order Reaction = (1/Space Time in Mixed Flow)*((Initial Reactant Concentration in Mixed Flow-Reactant Concentration at given Time)/Reactant Concentration at given Time)
Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Initial Reactant Concentration in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Reactant Conversion in Mixed Flow
Rate Constant for First Order Reaction using Space Time for Mixed Flow
​ LaTeX ​ Go Rate Constant for First Order Reaction = (1/Space Time in Mixed Flow)*(Reactant Conversion in Mixed Flow/(1-Reactant Conversion in Mixed Flow))

Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow Formula

​LaTeX ​Go
Initial Reactant Concentration in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Reactant Conversion in Mixed Flow
Co = (kmixed flow*𝛕mixed)/Xmfr

What is continuous stirred-tank reactor?

The continuous stirred-tank reactor (CSTR), also known as vat- or backmix reactor, mixed flow reactor (MFR), or a continuous-flow stirred-tank reactor (CFSTR), is a common model for a chemical reactor in chemical engineering and environmental engineering. A CSTR often refers to a model used to estimate the key unit operation variables when using a continuous agitated-tank reactor to reach a specified output. The mathematical model works for all fluids: liquids, gases, and slurries.

How to Calculate Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow?

Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow calculator uses Initial Reactant Concentration in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Reactant Conversion in Mixed Flow to calculate the Initial Reactant Concentration in Mixed Flow, The Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow formula is defined as the concentration of reactant before the considered reaction for zero order reaction for mixed flow where there is zero fractional volume change. Initial Reactant Concentration in Mixed Flow is denoted by Co symbol.

How to calculate Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow using this online calculator? To use this online calculator for Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow, enter Rate Constant for Zero Order in Mixed Flow (kmixed flow), Space Time in Mixed Flow (𝛕mixed) & Reactant Conversion in Mixed Flow (Xmfr) and hit the calculate button. Here is how the Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow calculation can be explained with given input values -> 78.87324 = (1125*0.05)/0.71.

FAQ

What is Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow?
The Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow formula is defined as the concentration of reactant before the considered reaction for zero order reaction for mixed flow where there is zero fractional volume change and is represented as Co = (kmixed flow*𝛕mixed)/Xmfr or Initial Reactant Concentration in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Reactant Conversion in Mixed Flow. The Rate Constant for Zero Order in Mixed Flow is equal to the rate of the reaction as the rate of reaction is proportional to zero power of the concentration of the reactant, Space Time in Mixed Flow is the time necessary to process volume of reactor fluid at the entrance conditions & Reactant Conversion in Mixed Flow gives us the percentage of reactants converted into products. Enter the percentage as a decimal between 0 and 1.
How to calculate Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow?
The Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow formula is defined as the concentration of reactant before the considered reaction for zero order reaction for mixed flow where there is zero fractional volume change is calculated using Initial Reactant Concentration in Mixed Flow = (Rate Constant for Zero Order in Mixed Flow*Space Time in Mixed Flow)/Reactant Conversion in Mixed Flow. To calculate Initial Reactant Concentration for Zero Order Reaction using Space Time for Mixed Flow, you need Rate Constant for Zero Order in Mixed Flow (kmixed flow), Space Time in Mixed Flow (𝛕mixed) & Reactant Conversion in Mixed Flow (Xmfr). With our tool, you need to enter the respective value for Rate Constant for Zero Order in Mixed Flow, Space Time in Mixed Flow & Reactant Conversion in Mixed Flow and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Initial Reactant Concentration in Mixed Flow?
In this formula, Initial Reactant Concentration in Mixed Flow uses Rate Constant for Zero Order in Mixed Flow, Space Time in Mixed Flow & Reactant Conversion in Mixed Flow. We can use 2 other way(s) to calculate the same, which is/are as follows -
  • Initial Reactant Concentration in Mixed Flow = (Reactant Conversion in Mixed Flow)/((1-Reactant Conversion in Mixed Flow)^2*(Space Time in Mixed Flow)*(Rate Constant for Second Order in Mixed Flow))
  • Initial Reactant Concentration in Mixed Flow = (Reactant Conversion in Mixed Flow)/((1-Reactant Conversion in Mixed Flow)^2*(Space Time in Mixed Flow)*(Rate Constant for Second Order in Mixed Flow))
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!