Influent BOD given Specific Substrate Utilization Rate Per Day Solution

STEP 0: Pre-Calculation Summary
Formula Used
Influent BOD given Substrate Utilization Rate = ((Specific Substrate Utilization Rate*Volume of Tank*Mixed Liquor Suspended Solids)/Sewage Discharge)+Effluent BOD
Qi' = ((U*V*X')/Qs)+Qo
This formula uses 6 Variables
Variables Used
Influent BOD given Substrate Utilization Rate - (Measured in Kilogram per Cubic Meter) - Influent BOD given Substrate Utilization Rate is the measure of the organic load entering a wastewater treatment system based on the rate at which microorganisms consume organic matter.
Specific Substrate Utilization Rate - (Measured in 1 Per Second) - Specific Substrate Utilization Rate is the rate at which a microbial population consumes a substrate per unit of biomass present.
Volume of Tank - (Measured in Cubic Meter) - Volume of Tank is defined as the capacity of flocculation and mixing tank.
Mixed Liquor Suspended Solids - (Measured in Kilogram per Cubic Meter) - Mixed Liquor Suspended Solids is the concentration of suspended solids in the mixed liquor of an aeration tank during the activated sludge process.
Sewage Discharge - (Measured in Cubic Meter per Second) - Sewage Discharge is the flow rate of sewage when it is being discharged in the river.
Effluent BOD - (Measured in Kilogram per Cubic Meter) - Effluent BOD is the amount of BOD present in the outing sewage.
STEP 1: Convert Input(s) to Base Unit
Specific Substrate Utilization Rate: 0.5 1 Per Second --> 0.5 1 Per Second No Conversion Required
Volume of Tank: 9 Cubic Meter --> 9 Cubic Meter No Conversion Required
Mixed Liquor Suspended Solids: 1200 Milligram per Liter --> 1.2 Kilogram per Cubic Meter (Check conversion ​here)
Sewage Discharge: 10 Cubic Meter per Second --> 10 Cubic Meter per Second No Conversion Required
Effluent BOD: 0.4 Milligram per Liter --> 0.0004 Kilogram per Cubic Meter (Check conversion ​here)
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Qi' = ((U*V*X')/Qs)+Qo --> ((0.5*9*1.2)/10)+0.0004
Evaluating ... ...
Qi' = 0.5404
STEP 3: Convert Result to Output's Unit
0.5404 Kilogram per Cubic Meter -->540.4 Milligram per Liter (Check conversion ​here)
FINAL ANSWER
540.4 Milligram per Liter <-- Influent BOD given Substrate Utilization Rate
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Suraj Kumar
Birsa Institute of Technology (BIT), Sindri
Suraj Kumar has created this Calculator and 2100+ more calculators!
Verifier Image
Verified by Ishita Goyal
Meerut Institute of Engineering and Technology (MIET), Meerut
Ishita Goyal has verified this Calculator and 2600+ more calculators!

Influent and Effluent BOD Calculators

Influent BOD given Mass of Wasted Activated Sludge
​ LaTeX ​ Go Influent BOD = ((Mass of Wasted Activated Sludge+(Endogenous Respiration Rate Constant*Volume of Tank*Mixed Liquor Suspended Solids))/(Maximum Yield Coefficient*Sewage Discharge))+Effluent BOD
Effluent BOD given Mass of Wasted Activated Sludge
​ LaTeX ​ Go Effluent BOD = Influent BOD-((Mass of Wasted Activated Sludge+(Endogenous Respiration Rate Constant*Volume of Tank*Mixed Liquor Suspended Solids))/(Maximum Yield Coefficient*Sewage Discharge))
Influent BOD given Specific Substrate Utilization Rate Per Day
​ LaTeX ​ Go Influent BOD given Substrate Utilization Rate = ((Specific Substrate Utilization Rate*Volume of Tank*Mixed Liquor Suspended Solids)/Sewage Discharge)+Effluent BOD

Influent BOD given Specific Substrate Utilization Rate Per Day Formula

​LaTeX ​Go
Influent BOD given Substrate Utilization Rate = ((Specific Substrate Utilization Rate*Volume of Tank*Mixed Liquor Suspended Solids)/Sewage Discharge)+Effluent BOD
Qi' = ((U*V*X')/Qs)+Qo

What is Effluent BOD?

BOD of wastewater effluents is used to indicate the short-term impact on the oxygen levels of the receiving water. BOD analysis is similar in function to chemical oxygen demand (COD) analysis, in that both measure the amount of organic compounds in water.

How to Calculate Influent BOD given Specific Substrate Utilization Rate Per Day?

Influent BOD given Specific Substrate Utilization Rate Per Day calculator uses Influent BOD given Substrate Utilization Rate = ((Specific Substrate Utilization Rate*Volume of Tank*Mixed Liquor Suspended Solids)/Sewage Discharge)+Effluent BOD to calculate the Influent BOD given Substrate Utilization Rate, The Influent BOD given Specific Substrate Utilization Rate Per Day formula is defined as the calculation of influent BOD when we have prior information of specific substrate utilization rate per day. Influent BOD given Substrate Utilization Rate is denoted by Qi' symbol.

How to calculate Influent BOD given Specific Substrate Utilization Rate Per Day using this online calculator? To use this online calculator for Influent BOD given Specific Substrate Utilization Rate Per Day, enter Specific Substrate Utilization Rate (U), Volume of Tank (V), Mixed Liquor Suspended Solids (X'), Sewage Discharge (Qs) & Effluent BOD (Qo) and hit the calculate button. Here is how the Influent BOD given Specific Substrate Utilization Rate Per Day calculation can be explained with given input values -> 540400 = ((0.5*9*1.2)/10)+0.0004.

FAQ

What is Influent BOD given Specific Substrate Utilization Rate Per Day?
The Influent BOD given Specific Substrate Utilization Rate Per Day formula is defined as the calculation of influent BOD when we have prior information of specific substrate utilization rate per day and is represented as Qi' = ((U*V*X')/Qs)+Qo or Influent BOD given Substrate Utilization Rate = ((Specific Substrate Utilization Rate*Volume of Tank*Mixed Liquor Suspended Solids)/Sewage Discharge)+Effluent BOD. Specific Substrate Utilization Rate is the rate at which a microbial population consumes a substrate per unit of biomass present, Volume of Tank is defined as the capacity of flocculation and mixing tank, Mixed Liquor Suspended Solids is the concentration of suspended solids in the mixed liquor of an aeration tank during the activated sludge process, Sewage Discharge is the flow rate of sewage when it is being discharged in the river & Effluent BOD is the amount of BOD present in the outing sewage.
How to calculate Influent BOD given Specific Substrate Utilization Rate Per Day?
The Influent BOD given Specific Substrate Utilization Rate Per Day formula is defined as the calculation of influent BOD when we have prior information of specific substrate utilization rate per day is calculated using Influent BOD given Substrate Utilization Rate = ((Specific Substrate Utilization Rate*Volume of Tank*Mixed Liquor Suspended Solids)/Sewage Discharge)+Effluent BOD. To calculate Influent BOD given Specific Substrate Utilization Rate Per Day, you need Specific Substrate Utilization Rate (U), Volume of Tank (V), Mixed Liquor Suspended Solids (X'), Sewage Discharge (Qs) & Effluent BOD (Qo). With our tool, you need to enter the respective value for Specific Substrate Utilization Rate, Volume of Tank, Mixed Liquor Suspended Solids, Sewage Discharge & Effluent BOD and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.