Indicated Power for Double-acting Compressor Solution

STEP 0: Pre-Calculation Summary
Formula Used
Indicated Power in Compressor = (Work Done during Polytropic Compression*2*Speed in RPM)/60
PIndicated = (WPolytropic*2*N)/60
This formula uses 3 Variables
Variables Used
Indicated Power in Compressor - (Measured in Watt) - Indicated Power in Compressor is the power required by a compressor to compress air or gas to a desired pressure and volume.
Work Done during Polytropic Compression - (Measured in Joule) - Work Done during Polytropic Compression is the energy transferred during the compression of a gas in a polytropic process, requiring a specific power input.
Speed in RPM - Speed in RPM is the rate of rotation of an object per minute, used to calculate the power required for a specific application or process.
STEP 1: Convert Input(s) to Base Unit
Work Done during Polytropic Compression: 8 Joule --> 8 Joule No Conversion Required
Speed in RPM: 58.5 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
PIndicated = (WPolytropic*2*N)/60 --> (8*2*58.5)/60
Evaluating ... ...
PIndicated = 15.6
STEP 3: Convert Result to Output's Unit
15.6 Watt --> No Conversion Required
FINAL ANSWER
15.6 Watt <-- Indicated Power in Compressor
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Vishwakarma Institute of Information Technology, Pune (VIIT Pune), Pune
Abhishek Dharmendra Bansile has created this Calculator and 100+ more calculators!
Verifier Image
Verified by Anshika Arya
National Institute Of Technology (NIT), Hamirpur
Anshika Arya has verified this Calculator and 2500+ more calculators!

Power Required Calculators

Indicated Power for Double-acting Compressor
​ LaTeX ​ Go Indicated Power in Compressor = (Work Done during Polytropic Compression*2*Speed in RPM)/60
Indicated Power for Single-acting Compressor
​ LaTeX ​ Go Indicated Power in Compressor = (Work Done during Polytropic Compression*Speed in RPM)/60
Isothermal Power for Double-acting Compressor
​ LaTeX ​ Go Isothermal Power = (Work Done during Isothermal Compression*2*Speed in RPM)/60
Isothermal Power for Single-acting Compressor
​ LaTeX ​ Go Isothermal Power = (Work Done during Isothermal Compression*Speed in RPM)/60

Indicated Power for Double-acting Compressor Formula

​LaTeX ​Go
Indicated Power in Compressor = (Work Done during Polytropic Compression*2*Speed in RPM)/60
PIndicated = (WPolytropic*2*N)/60

What is Double Acting Compressor?

The double acting compressor compresses the air on both the up-stroke and the down-stroke of the piston, doubling the capacity of a given cylinder size. This “double” compression cycle is what makes this type of air compressor very efficient.

How to Calculate Indicated Power for Double-acting Compressor?

Indicated Power for Double-acting Compressor calculator uses Indicated Power in Compressor = (Work Done during Polytropic Compression*2*Speed in RPM)/60 to calculate the Indicated Power in Compressor, Indicated Power for Double-acting Compressor formula is defined as the total power required by a double-acting compressor to compress a given volume of air or gas, taking into account the polytropic work done and the number of revolutions per minute, providing a measure of the compressor's performance and efficiency. Indicated Power in Compressor is denoted by PIndicated symbol.

How to calculate Indicated Power for Double-acting Compressor using this online calculator? To use this online calculator for Indicated Power for Double-acting Compressor, enter Work Done during Polytropic Compression (WPolytropic) & Speed in RPM (N) and hit the calculate button. Here is how the Indicated Power for Double-acting Compressor calculation can be explained with given input values -> 15.6 = (8*2*58.5)/60.

FAQ

What is Indicated Power for Double-acting Compressor?
Indicated Power for Double-acting Compressor formula is defined as the total power required by a double-acting compressor to compress a given volume of air or gas, taking into account the polytropic work done and the number of revolutions per minute, providing a measure of the compressor's performance and efficiency and is represented as PIndicated = (WPolytropic*2*N)/60 or Indicated Power in Compressor = (Work Done during Polytropic Compression*2*Speed in RPM)/60. Work Done during Polytropic Compression is the energy transferred during the compression of a gas in a polytropic process, requiring a specific power input & Speed in RPM is the rate of rotation of an object per minute, used to calculate the power required for a specific application or process.
How to calculate Indicated Power for Double-acting Compressor?
Indicated Power for Double-acting Compressor formula is defined as the total power required by a double-acting compressor to compress a given volume of air or gas, taking into account the polytropic work done and the number of revolutions per minute, providing a measure of the compressor's performance and efficiency is calculated using Indicated Power in Compressor = (Work Done during Polytropic Compression*2*Speed in RPM)/60. To calculate Indicated Power for Double-acting Compressor, you need Work Done during Polytropic Compression (WPolytropic) & Speed in RPM (N). With our tool, you need to enter the respective value for Work Done during Polytropic Compression & Speed in RPM and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Indicated Power in Compressor?
In this formula, Indicated Power in Compressor uses Work Done during Polytropic Compression & Speed in RPM. We can use 1 other way(s) to calculate the same, which is/are as follows -
  • Indicated Power in Compressor = (Work Done during Polytropic Compression*Speed in RPM)/60