Incident Voltage of Incident Wave Solution

STEP 0: Pre-Calculation Summary
Formula Used
Incident Voltage = Incident Current*Characteristic Impedance
Vi = Ii*Z0
This formula uses 3 Variables
Variables Used
Incident Voltage - (Measured in Volt) - The Incident Voltage on the transmission line is equal to half the generator voltage.
Incident Current - (Measured in Ampere) - Incident Current is the Current wave that is traveling from the sending end to the receiving end of the Transmission line during any transient condition.
Characteristic Impedance - (Measured in Ohm) - The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line during transient condition.
STEP 1: Convert Input(s) to Base Unit
Incident Current: 12 Ampere --> 12 Ampere No Conversion Required
Characteristic Impedance: 55.5 Ohm --> 55.5 Ohm No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Vi = Ii*Z0 --> 12*55.5
Evaluating ... ...
Vi = 666
STEP 3: Convert Result to Output's Unit
666 Volt --> No Conversion Required
FINAL ANSWER
666 Volt <-- Incident Voltage
(Calculation completed in 00.004 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Kethavath Srinath
Osmania University (OU), Hyderabad
Kethavath Srinath has verified this Calculator and 1200+ more calculators!

Transient Calculators

Load Impedance using Reflected Coefficient of Current
​ LaTeX ​ Go Load Impedance = Characteristic Impedance*(1-Reflection Coefficient of Current)/(Reflection Coefficient of Current-1)
Load Impedance using Reflected Coefficient of Voltage
​ LaTeX ​ Go Load Impedance = Characteristic Impedance*(Reflection Coefficient of Voltage+1)/(1-Reflection Coefficient of Voltage)
Characteristic Impedance (Line SC)
​ LaTeX ​ Go Characteristic Impedance = Incident Voltage/Incident Current
Incident Voltage using Transmitted Voltage (Load OC)
​ LaTeX ​ Go Incident Voltage = Transmitted Voltage/2

Incident Voltage of Incident Wave Formula

​LaTeX ​Go
Incident Voltage = Incident Current*Characteristic Impedance
Vi = Ii*Z0

Define characteristic impedance.

The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line.

How to Calculate Incident Voltage of Incident Wave?

Incident Voltage of Incident Wave calculator uses Incident Voltage = Incident Current*Characteristic Impedance to calculate the Incident Voltage, The Incident Voltage of Incident Wave formula is defined as the voltage wave that is traveling from the sending end to the receiving end of the Transmission line. Incident Voltage is denoted by Vi symbol.

How to calculate Incident Voltage of Incident Wave using this online calculator? To use this online calculator for Incident Voltage of Incident Wave, enter Incident Current (Ii) & Characteristic Impedance (Z0) and hit the calculate button. Here is how the Incident Voltage of Incident Wave calculation can be explained with given input values -> 666 = 12*55.5.

FAQ

What is Incident Voltage of Incident Wave?
The Incident Voltage of Incident Wave formula is defined as the voltage wave that is traveling from the sending end to the receiving end of the Transmission line and is represented as Vi = Ii*Z0 or Incident Voltage = Incident Current*Characteristic Impedance. Incident Current is the Current wave that is traveling from the sending end to the receiving end of the Transmission line during any transient condition & The characteristic impedance of a uniform transmission line is the ratio of the amplitudes of voltage and current of a single wave propagating along the line during transient condition.
How to calculate Incident Voltage of Incident Wave?
The Incident Voltage of Incident Wave formula is defined as the voltage wave that is traveling from the sending end to the receiving end of the Transmission line is calculated using Incident Voltage = Incident Current*Characteristic Impedance. To calculate Incident Voltage of Incident Wave, you need Incident Current (Ii) & Characteristic Impedance (Z0). With our tool, you need to enter the respective value for Incident Current & Characteristic Impedance and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Incident Voltage?
In this formula, Incident Voltage uses Incident Current & Characteristic Impedance. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Incident Voltage = Transmitted Voltage/2
  • Incident Voltage = Reflected Voltage*(Load Impedance+Characteristic Impedance)/(Load Impedance-Characteristic Impedance)
  • Incident Voltage = Transmitted Voltage-Reflected Voltage
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!