Impedance-3 using Transmitted Coefficient of Current-3 (Line PL) Solution

STEP 0: Pre-Calculation Summary
Formula Used
Impedance of Tertiary Winding = Transmitted Voltage*Impedance of Primary Winding/(Incident Voltage*Transmission Coefficient of Current)
Z3 = Vt*Z1/(Vi*τi)
This formula uses 5 Variables
Variables Used
Impedance of Tertiary Winding - (Measured in Ohm) - Impedance of Tertiary Winding in electrical devices, refers to the amount of opposition faced by the direct or alternating current when it passes through a conductor component, circuit, or system.
Transmitted Voltage - (Measured in Volt) - Transmitted Voltage is defined as the Voltage wave that is traveling through the Load of the Transmission line.
Impedance of Primary Winding - (Measured in Ohm) - The Impedance of Primary Winding is the total of primary Resistance and Reactance.
Incident Voltage - (Measured in Volt) - The Incident Voltage on the transmission line is equal to half the generator voltage.
Transmission Coefficient of Current - The transmission Coefficient Of Current is defined as the ratio of the transmitted current to the incident current of the Transmission line during transient.
STEP 1: Convert Input(s) to Base Unit
Transmitted Voltage: 20 Volt --> 20 Volt No Conversion Required
Impedance of Primary Winding: 18 Ohm --> 18 Ohm No Conversion Required
Incident Voltage: 6 Volt --> 6 Volt No Conversion Required
Transmission Coefficient of Current: 7 --> No Conversion Required
STEP 2: Evaluate Formula
Substituting Input Values in Formula
Z3 = Vt*Z1/(Vii) --> 20*18/(6*7)
Evaluating ... ...
Z3 = 8.57142857142857
STEP 3: Convert Result to Output's Unit
8.57142857142857 Ohm --> No Conversion Required
FINAL ANSWER
8.57142857142857 8.571429 Ohm <-- Impedance of Tertiary Winding
(Calculation completed in 00.020 seconds)

Credits

Creator Image
Created by Urvi Rathod
Vishwakarma Government Engineering College (VGEC), Ahmedabad
Urvi Rathod has created this Calculator and 1500+ more calculators!
Verifier Image
Verified by Payal Priya
Birsa Institute of Technology (BIT), Sindri
Payal Priya has verified this Calculator and 1900+ more calculators!

Impedance 1,2 and 3 Calculators

Impedance-1 using Transmitted Voltage (Line PL)
​ LaTeX ​ Go Impedance of Primary Winding = (Incident Voltage-Reflected Voltage)*(Impedance of Secondary Winding+Impedance of Tertiary Winding)/Transmitted Voltage
Impedance-2 using Transmitted Current-2 (Line PL)
​ LaTeX ​ Go Impedance of Secondary Winding = Transmitted Voltage/Transmitted Current
Impedance-2 using Transmitted Voltage (Line PL)
​ LaTeX ​ Go Impedance of Secondary Winding = Transmitted Voltage/Transmitted Current
Impedance-3 using Transmitted Voltage (Line PL)
​ LaTeX ​ Go Impedance of Tertiary Winding = Transmitted Voltage/Transmitted Current

Impedance-3 using Transmitted Coefficient of Current-3 (Line PL) Formula

​LaTeX ​Go
Impedance of Tertiary Winding = Transmitted Voltage*Impedance of Primary Winding/(Incident Voltage*Transmission Coefficient of Current)
Z3 = Vt*Z1/(Vi*τi)

What is Transmitted Coefficient Of Current-3?

Transmitted Coefficient Of Current-3 is defined as the ratio of the transmitted Current-3 to the incident Current of the Transmission line.

How to Calculate Impedance-3 using Transmitted Coefficient of Current-3 (Line PL)?

Impedance-3 using Transmitted Coefficient of Current-3 (Line PL) calculator uses Impedance of Tertiary Winding = Transmitted Voltage*Impedance of Primary Winding/(Incident Voltage*Transmission Coefficient of Current) to calculate the Impedance of Tertiary Winding, The Impedance-3 using Transmitted Coefficient of Current-3 (line PL) formula is defined as a measure of the overall opposition of a circuit to current, in other words: how much the circuit impedes the flow of charge. It is like resistance, but it also takes into account the effects of capacitance and inductance. Impedance is measured in ohms. Impedance of Tertiary Winding is denoted by Z3 symbol.

How to calculate Impedance-3 using Transmitted Coefficient of Current-3 (Line PL) using this online calculator? To use this online calculator for Impedance-3 using Transmitted Coefficient of Current-3 (Line PL), enter Transmitted Voltage (Vt), Impedance of Primary Winding (Z1), Incident Voltage (Vi) & Transmission Coefficient of Current i) and hit the calculate button. Here is how the Impedance-3 using Transmitted Coefficient of Current-3 (Line PL) calculation can be explained with given input values -> 8.571429 = 20*18/(6*7).

FAQ

What is Impedance-3 using Transmitted Coefficient of Current-3 (Line PL)?
The Impedance-3 using Transmitted Coefficient of Current-3 (line PL) formula is defined as a measure of the overall opposition of a circuit to current, in other words: how much the circuit impedes the flow of charge. It is like resistance, but it also takes into account the effects of capacitance and inductance. Impedance is measured in ohms and is represented as Z3 = Vt*Z1/(Vii) or Impedance of Tertiary Winding = Transmitted Voltage*Impedance of Primary Winding/(Incident Voltage*Transmission Coefficient of Current). Transmitted Voltage is defined as the Voltage wave that is traveling through the Load of the Transmission line, The Impedance of Primary Winding is the total of primary Resistance and Reactance, The Incident Voltage on the transmission line is equal to half the generator voltage & The transmission Coefficient Of Current is defined as the ratio of the transmitted current to the incident current of the Transmission line during transient.
How to calculate Impedance-3 using Transmitted Coefficient of Current-3 (Line PL)?
The Impedance-3 using Transmitted Coefficient of Current-3 (line PL) formula is defined as a measure of the overall opposition of a circuit to current, in other words: how much the circuit impedes the flow of charge. It is like resistance, but it also takes into account the effects of capacitance and inductance. Impedance is measured in ohms is calculated using Impedance of Tertiary Winding = Transmitted Voltage*Impedance of Primary Winding/(Incident Voltage*Transmission Coefficient of Current). To calculate Impedance-3 using Transmitted Coefficient of Current-3 (Line PL), you need Transmitted Voltage (Vt), Impedance of Primary Winding (Z1), Incident Voltage (Vi) & Transmission Coefficient of Current i). With our tool, you need to enter the respective value for Transmitted Voltage, Impedance of Primary Winding, Incident Voltage & Transmission Coefficient of Current and hit the calculate button. You can also select the units (if any) for Input(s) and the Output as well.
How many ways are there to calculate Impedance of Tertiary Winding?
In this formula, Impedance of Tertiary Winding uses Transmitted Voltage, Impedance of Primary Winding, Incident Voltage & Transmission Coefficient of Current. We can use 3 other way(s) to calculate the same, which is/are as follows -
  • Impedance of Tertiary Winding = Transmitted Voltage/Transmitted Current
  • Impedance of Tertiary Winding = (2/(Impedance of Primary Winding*Transmission Coefficient of Voltage))-(1/Impedance of Primary Winding)-(1/Impedance of Secondary Winding)
  • Impedance of Tertiary Winding = Transmission Coefficient of Voltage*Impedance of Primary Winding/Transmission Coefficient of Current
Let Others Know
Facebook
Twitter
Reddit
LinkedIn
Email
WhatsApp
Copied!